MONTHYEARIR 05000387/20240102024-11-13013 November 2024 Biennial Problem Identification and Resolution Inspection Report 05000387/2024010 and 05000388/2024010 IR 05000387/20245012024-11-13013 November 2024 Emergency Preparedness Biennial Exercise Inspection Report 05000387/2024501 and 05000388/2024501 IR 05000387/20240032024-11-12012 November 2024 Integrated Inspection Report 05000387/2024003 and 05000388/2024003 IR 05000387/20240052024-08-29029 August 2024 Updated Inspection Plan for Susquehanna Steam Electric Station, Units 1 and 2 (Report 05000387/2024005 and 05000388/2024005) IR 05000387/20240022024-08-12012 August 2024 Integrated Inspection Report 05000387/2024002 and 05000388/2024002 IR 05000387/20240012024-05-13013 May 2024 Integrated Inspection Report 05000387/2024001 and 05000388/2024001 IR 05000387/20244042024-05-0707 May 2024 Information Request for the Cybersecurity Baseline Inspection, Notification to Perform Inspection 05000387/2024404 and 05000388/2024404 IR 05000387/20240112024-02-29029 February 2024 Commercial Grade Dedication Inspection Report 05000387/2024011 and 05000388/2024011 IR 05000387/20230062024-02-28028 February 2024 Annual Assessment Letter for Susquehanna Steam Electric Station, Units 1 and 2 (Reports 05000387/2023006 and 05000388/2023006) IR 05000387/20230042024-02-0707 February 2024 Integrated Inspection Report 05000387/2023004 and 05000388/2023004 IR 05000387/20230102023-12-11011 December 2023 Fire Protection Team Inspection Report 05000387/2023010 and 05000388/2023010 IR 05000387/20230032023-11-0303 November 2023 Integrated Inspection Report 05000387/2023003 and 05000388/2023003 IR 05000387/20233012023-09-20020 September 2023 Initial Operator Licensing Examination Report 05000387/2023301 and 05000388/2023301 IR 05000387/20230052023-08-31031 August 2023 Updated Inspection Plan for Susquehanna Steam Electric Station, Units 1 and 2 (Report 05000387/2023005 and 05000388/2023005) IR 05000387/20230022023-08-0101 August 2023 Integrated Inspection Report 05000387/2023002 and 05000388/2023002 IR 05000387/20234012023-06-0707 June 2023 Security Baseline Inspection Report 05000387/2023401 and 05000388/2023401 IR 05000387/20230012023-05-12012 May 2023 Integrated Inspection Report 05000387/2023001 and 05000388/2023001 IR 05000387/20220062023-03-0101 March 2023 Annual Assessment Letter for Susquehanna Steam Electric Station, Units 1 and 2 (Reports 05000387/2022006 and 05000388/2022006) IR 05000387/20220042023-02-0808 February 2023 Integrated Inspection Report 05000387/2022004 and 05000388/2022004 IR 07200028/20220012022-12-15015 December 2022 Independent Spent Fuel Storage Installation (ISFSI) - NRC Inspection Report No. 07200028/2022001 IR 05000387/20224032022-11-29029 November 2022 Security Baseline Inspection Report 05000387/2022403 and 05000388/2022403 IR 05000387/20225012022-11-28028 November 2022 Emergency Preparedness Biennial Exercise Inspection Report 05000387/2022501 and 05000388/2022501 IR 05000387/20220032022-11-0808 November 2022 Integrated Inspection Report 05000387/2022003 and 05000388/2022003 IR 05000387/20220132022-09-28028 September 2022 Design Basis Assurance Inspection (Teams) Inspection Report 05000387/2022013 and 05000388/2022013 IR 05000387/20220052022-08-31031 August 2022 Updated Inspection Plan for Susquehanna Steam Electric Station, Units 1 and 2 (Report 05000387/2022005 and 05000388/2022005) IR 05000387/20224012022-08-11011 August 2022 Material Control and Accounting Program Inspection Report 05000387/2022401 and 05000388/2022401 (Cover Letter Only) IR 05000387/20220102022-08-11011 August 2022 Biennial Problem Identification and Resolution Inspection Report 05000387/2022010 and 05000388/2022010 IR 05000387/20220022022-08-0404 August 2022 Integrated Inspection Report 05000387/2022002 and 05000388/2022002 IR 05000387/20224042022-05-26026 May 2022 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000387/2022404 and 05000388/2022404 IR 05000387/20220012022-05-0909 May 2022 Integrated Inspection Report 05000387/2022001 and 05000388/2022001 IR 05000387/20220112022-03-0707 March 2022 Post-Approval Site Inspection for License Renewal - Phase 2 Inspection Report 05000387/2022011 IR 05000387/20210062022-03-0202 March 2022 Annual Assessment Letter for Susquehanna Steam Electric Station, Units 1 and 2 (Reports 05000387/2021006 and 05000388/2021006) IR 05000387/20224022022-02-16016 February 2022 Security Baseline Inspection Report 05000387/2022402 and 05000388/2022402 IR 05000387/20210042022-02-11011 February 2022 Integrated Inspection Report 05000387/2021004 and 05000388/2021004 IR 05000387/20214032022-02-11011 February 2022 Cyber Security Problem Identification and Resolution Inspection Report 05000387/2021403 and 05000388/2021403 (Cover Letter Only) IR 05000387/20210112021-11-0404 November 2021 Temporary Instruction 2515/194 Inspection Report 05000387/2021011 and 05000388/2021011 IR 05000387/20210032021-11-0303 November 2021 Integrated Inspection Report 05000387/2021003 and 05000388/2021003 IR 05000387/20214012021-10-25025 October 2021 Security Baseline Inspection Report 05000387/2021401 and 05000388/2021401 IR 05000387/20214022021-09-23023 September 2021 Security Baseline Inspection Report 05000387/2021402 and 05000388/2021402 IR 05000387/20213012021-09-17017 September 2021 Initial Operator Licensing Examination Report 05000387/2021301 and 05000388/2021301 IR 05000387/20210052021-09-0101 September 2021 Updated Inspection Plan for the Susquehanna Steam Electric Station, Units 1 and 2 (Report 05000387/2021005 and 05000388/2021005) ML21224A2402021-08-24024 August 2021 Security Baseline Inspection Report Cover Letter 2021 FOF IR 05000387/20210022021-08-0404 August 2021 Integrated Inspection Report 05000387/2021002 and 05000388/2021002 IR 05000387/20210102021-07-29029 July 2021 Information Request to Support Triennial Baseline Design-Basis Capability of Power-Operated Valves Inspection; Inspection Report 05000387/2021010 and 05000388/2021010 IR 05000387/20210012021-05-0505 May 2021 Integrated Inspection Report 05000387/2021001 and 05000388/2021001 IR 05000388/20210122021-03-0404 March 2021 EA-20-131: Susquehanna Steam Electric Station, Unit 2 - NRC Investigation Report No. 1-2020-001 and NRC Inspection Report No. 05000388/2021012 IR 05000387/20200062021-03-0303 March 2021 Annual Assessment Letter for Susquehanna Steam Electric Station, Units 1 and 2 (Reports 05000387/2020006 and 05000388/2020006) IR 05000387/20204032021-02-10010 February 2021 Cyber Security Problem Identification and Resolution Inspection Report 05000387/2020403 and 05000388/2020403 (Cover Letter Only) IR 05000387/20200042021-02-0808 February 2021 Integrated Inspection Report 05000387/2020004 and 05000388/2020004 IR 05000387/20205012020-11-18018 November 2020 Emergency Preparedness Biennial Exercise Inspection Report 05000387/2020501 and 05000388/2020501 2024-08-29
[Table view] |
Text
U.S. NUCLEAR REGULATORY COMMISSION
REGION I
INSPECTION REPORT Docket No and 50-388 License No NPF-14 and NPF-22 Report No /2009405 and 05000388/2009405 Licensee: PPL Susquehanna, LLC Facility Susquehanna Steam Electric Location: Berwick, Pennsylvania Inspection Dates: August 17-20, 2009 Inspector: Orysia M. Masnyk Bailey, Health Physicist Decommissioning Branch Division of Nuclear Materials Safety (DNMS)
Approved By:
Judith A. Joustra, Chief Decommissioning Branch DNMS Enclosure
SUMMARY OF FINDINGS
IR 05000387/2009405 and 05000388/2009405; Susquehanna Steam Electric Station;
Independent Spent Fuel Storage Installation (ISFSI) Security Inspection This report covers an announced inspection conducted by a regional-based ISFSI/decommissioning inspector. This inspection consisted of a review and evaluation of the physical security program for the ISFSI at the Susquehanna Steam Electric Station in Berwick,
Pennsylvania. The inspection consisted of observations of ISFSI physical security related activities in progress, evaluation of additional security measures (ASMs) in place for the ISFSI, interviews with personnel, and an examination of procedures and security records. The inspector used Temporary Instruction (TI) 2690/008, Inspections of ASMs for Dry Cask Storage at ISFSI(s) located within the Protected Area of an Operating Reactor Facility to conduct the inspection.
NRC-Identified and Self-Revealing Findings
ISFSI Security No findings of significance were identified. (Section 1.1)
REPORT DETAILS
1.0 ISFSI Security 1.1 Independent Spent Fuel Storage Installation (ISFSI) located within the PA of an Operating Reactor Facility (TI 2690/008)
a. Inspection Scope
The inspector reviewed the Susquehanna Steam Electric Stations Physical Security Plan (PSP) and implementation of the requirements of the Additional Security Measures (ASMs) in place for the ISFSI. The inspector reviewed procedures and records (including training records) and interviewed security personnel. The inspector verified that the licensees facility had appropriate physical barriers, and had redundant communications capability between the onsite security force members and designated response force or the Local Law Enforcement Agency (LLEA). The inspector toured the ISFSI and Alarm Stations and observed the licensees security officers perform equipment functionality tests for communication systems between the Alarm Stations and security officers, LLEA; surveillance/assessment system; and intrusion alarm system.
Additionally, the inspector evaluated the licensees handling and storage of safeguards information in accordance with regulatory requirements.
b. Findings
No findings of significance were identified.
2.0 Exit Meeting The ISFSI security inspection results were discussed with C.J. Gannon, Vice President Nuclear Operations, and members of his staff on August 20, 2009, at the conclusion of on site inspection activities. The licensee did not identify any of the documents reviewed or statements referenced to specific processes as proprietary in nature.
ATTACHMENT:
SUPPLEMENTAL INFORMATION
A list of acronyms used in the report is included at the end of the Report Details.
SUPPLEMENTAL INFORMATION
PARTIAL LIST OF PERSONS CONTACTED
- C.J. Gannon, Vice President Nuclear Operations
Wally Beishline, Security Training Instructor
Bryan Mastonick, Security Training Instructor
John Paciotti, Site Security Operations Manager
Mike Sleigh, Security Manager
INSPECTION PROCEDURES USED
TI 2690/008 Inspection of ASMs for Dry Cask Storage at ISFSI(s) located within the PA of an
Operating Reactor Facility
IP 81001 Independent Spent Fuel Storage Installation(s) (Security Inspection Procedure)
ITEMS OPENED, CLOSED, AND DISCUSSED
Opened, Closed, and Discussed
None.
LIST OF DOCUMENTS REVIEWED
The following is a list of documents reviewed during the inspection. Inclusion on the list does
not imply the Nuclear Regulatory Commission (NRC) inspectors reviewed the documents in their
entirety but rather that selected sections or portions of the documents were evaluated as part of
the overall inspection effort. Inclusion of a document on this list does not imply NRC acceptance
of the document, or any part of it, unless this is stated in the body of the inspection report.
Physical Security Plan, Training and Qualification Plan, Safeguards Contingency Plan,
PPL Susquehanna, LLC, (Revision 6, dated May 2009)
Nuclear Intrusion Response Plan dated July 15, 2008
Vehicle Barrier System Design Calculation 1081763-C-012, (Revision 1 dated August 21, 2008)
Security Instruction-SO-004, Revision 10, Duties and Responsibilities of the Mobile Patrol
Officer
FSAR 72.212 dated November 09, 2007, XI, Physical Security Evaluation
ACRONYMS
ADAMS Agencywide Documents Access and Management System
ASM Additional Security Measures
CFR Code of Federal Regulations
DNMS Division of Nuclear Materials Safety
ISFSI Independent Spent Fuel Storage Installation
LLEA Local Law Enforcement Agency
NRC Nuclear Regulatory Commission
PARS Publicly Available Records System
PSP Physical Security Plan
TI Temporary Instruction
FSAR Final Safety Analysis Report
Attachment