NRC Inspection Report 50-338/01-09 and 50-339/01-09
ML020390158
Person / Time
Site: North Anna  
(NPF-004, NPF-007)
Issue date: 01/11/2002
From: Barr K
NRC/RGN-II
To: Christian D
Virginia Electric & Power Co (VEPCO)
References
IR-01-009
Download: ML020390158 (5)


Text

SUBJECT:

RAFEGUAROS INFORMATION REMOVED NRC INSPECTION REPORT 50-338/01-09 AND 50-339/01-09

Dear Mr. Christian:

On July 30 through August 3, 2001, the NRC completed an inspection at your North Anna Power Station, Units 1 and 2. The enclosed report documents the inspection findings which were discussed on August 3, 2001, with Mr. Tim Maddy, and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission's rules and regulations, and with the conditions of your license.

The inspectors reviewed selective procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, the inspectors identified two issues of very low safety significance (Green). These issues were determined to involve violations of NRC requirements.

However, due to their very low safety significance, and because they have been entered into your corrective action program, the NRC is treating these issues as Non-Cited Violations (NCVs), in accordance with Section VI.A.1 of the NRC's Enforcement Policy. If you deny these NCVs, you should provide a response with the basis for your denial, within 30 days of the date of this inspection report, to the United States Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, D.C. 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, D.C. 20555-0001; and the NRC Resident Inspector at the North Anna Power Station.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, without the enclosure which contains safeguards information, will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS).....................................

,i*

-'.

UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION II

SAM NUNN ATLANTA FEDERAL CENTER 61 FORSYTH STREET SW SUITE 23T85 ATLANTA, GEORGIA 30303-8931 January 11, 2002 VEPCO

WAFEGUARDS INFORMATION REMOVED component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.ciov/NRC/ADAMS/index.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Kenneth P. Barr, Chief Plant Support Branch Division of Reactor Safety Docket Nos.: 50-338, 50-339 License Nos.: NPF-4, NPF-7

Enclosure:

NRC Inspection Report 50-338/01-09; and 50-339/01-09 (Contains Safeguards Information)

x-6-<

PUBLIC DOCUMENT (circle one):

UrI-UI/L KrIt.UKU L,UI"T YES NO UL,,UIVI tImm I I/-MIVI.

F*:nOrif annaf._I.nal.wpU t' m-nllr!!~sm' t:Cý' i-rivd n:--s~n OFFICE R11 DRS RI1 DRP RI1 DRS RI1 RII RII SIGNATURE Wallo Landis Barr NAME JWaIIo KLandis 4KB4

_

_

_

_

_

DATE 1/ /02 1//-"I02 1/

NOU2

_

E-MAIL COPY?

YES NO YES YES-tiNýO

, YESNO YES NO YES VEPCO

REGION II==

Docket Nos.:

License Nos.:

Report Nos.:

Licensee:

Facility:

Location:

Dates:

Inspectors:

Approved by:

50-338, 50-339 NPF-4, NPF-7 50-338/01-09, 50-339/01-09 Virginia Electric and Power Company (VEPCO)

North Anna Power Station, Units 1 & 2 1022 Haley Drive Mineral, Virginia 23117 July 30 through August 3, 2001 Jon H. Wallo, Physical Security Inspector David A. Holman, Physical Security Inspector Kenneth P. Barr, Chief Plant Support Branch Division of Reactor Safety Document tr~ansmittedl bamimL 1

..,.:

  • .,,

sensitive pncassififd

,

I'-.,.

.,'1. scpmt'ad from

.idccumsnt is decontrole! SUMMARY OF FINDINGS IR 05000338/01-09, IR 05000339/01-09, on 7/30-8103/2001, Virginia Electric and Power Company, North Anna Power Station, Units 1 & 2, Response to Contingency Events.

The inspection was conducted by two region-based security inspectors. The inspection identified two Green findings, both of which were Non-Cited Violations. The significance of most findings is indicated by its color (Green, White, Yellow, Red) using Inspection Manual Chapter (IC) 0609, "Significance Determination Process" (SDP). Findings for which the SDP does not apply are indicated by "No Color" or by the severity level of the applicable violation. The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described at its Reactor Oversight Process website at http//www. nrc. qov/NRR/OVERSIGHT/index.html.

Cornerstone: Physical Protection A.

Inspector Identified Findings Green. A Non-Cited Violation of the North Anna (PSP), Paragraph 2.2.3 (a), Revision 7, was identified by the NRC inspectors.

While the risk is low in this case, the issue was identified as more than a minor finding because allowing individuals to penetrate the protected area perimeter without being detected could have a credible impact on safety and could be viewed as a precursor to a more significant event. Using the Physical Protection Significance Determination Process and identifying the finding as a vulnerability in Safeguards Systems or Plans, without an intrusion, and with fewer than two similar findings in four quarters, the finding was determined to be within the licensee response band and a Green finding.

(Section 3PP3)

Green. A Non-Cited Violation of the North Anna (PSP), Paragraph 4.2., Revision 7, was identified by NRC inspectors.

While the risk is low in this case, the issue was identified as more than a minor finding because allowing individuals to penetrate the protected area perimeter without being assessed could have a credible impact on safety and could be viewed as a precursor to a more significant event. Using the Physical Protection Significance Determination Process and identifying the finding as a vulnerability in Safeguards Systems or Plans, without an intrusion, and with fewer than two similar findings in four quarters, the finding was determined to be within the licensee response band and a Green finding.

(Section 3PP3) :..

" -

i is decontfl,