  • i

,o l

U. S. NUCLEAR REGULATORY COMMISSION REGIONlli Docket No:

50-331 License No:

DPR-49 i

Report No:

50-331/99006(DRS)

Licensee:

IES Utilities Inc.

]

Facility:

Duane Arnold Energy Center Location:

200 First Street S.E.

P. O. Box 351 Cedar Rapids, IA 52406-0351 Dates:

June 7-11,1999 Inspector:

Gary L. Pirtle, Physical Security inspector

'

Approved by:

James R. Creed

' Safeguards Team Leader Division of Reactor Safety

"

9906290182 990625 PDR ADOCK 05000331 G

PDR

  • 4

.

-'

.

I EXECUTIVE SUMMARY l

Duane Arnold Energy Center l

NRC Inspection Report 50-331/99006(DRS)

l

'

l This inspection included a review of the physical security program. It was an announced inspection conducted by a regional physical security specialist.

Observed security facilities were well maintained and security equipment functioned as e

l

. designed (Section S2).

l

Security procedures and records reviewed were complete and accurate. The need for clarification of part of a security plan revision was identified (Section S3),

Security personnel were very knowledgeable of post requirements and responsibilities e

and no deficiencies were identified. Security event logs were complete and accurate (Section S4).

Training records reviewed were complete and accurate. Administrative deficiencies e

within the weapon training program were entered into the licensee's corrective action program (Section SS).

Self-assessment efforts were varied and effective in identifying and resolving problems

(Section S7).

)

i

l j

%

a

,

ReDort Details IV. Plant Support S2 Status of Security Facilities and Equipment a.

Insoection Scope (81700)

The inspector reviewed the status and condition of security facilities and equipment

'

required by the security plan. The equipment and facilities observed included, but were not limited to, intrusion detection equipment, assessment equipment, search equipment, alarm station, and the main access controi facility.

b.

Observation and Findino i

Search equipment at the Main Access Facility functioned as designed during observed licensee testing of the equipment. Security force members assigned to those locations were properly equipped with communications and weapons, when required. Observed daily testing of alarm zones was comp!eted in accordance with procedures, and alarm-related equipment functioned as designed during such testing. Security equipment within the alarm station was functional, well maintained and operators were aware of the system capabilities and the system status for alarm points. Maintenance support for security equipment was generally timely.

c.

Conclusions Observed security facilities were well maintained and security equipment functioned as designed.

S3 Security and Safeguards Procedures and Documentation

'

a.

Inappction Scope (81700)

)

The inspector reviewed selected security procedures pertaining to the areas inspected and also reviewed appropriate logs, records, and other documentation pertaining to the areas inspected.

b.

Observation and Findina No deficiencies were identified during review of security procedures. The procedures reviewed were well v an and in sufficient depth to describe the tasks to be performed.

Records reviewed weio.amplete and accurate.

Onsite evaluations of two revisions to the security plan were completed. The revisions were submitted under the provisions of 10 CFR 50.54(p), and pertained to: expanded use of closed circuit television (CCTV) for compensatory measures; changing the primary contingency weapon; and increasing the use of unarmed security force

m

p s

-

, -

,

personnel for securing protected area portals. No questions arose in reference to expanded use of CCTV, or a change in the primary contingency response weapon.

However, clarification was needed on the increased use of unarmed security personnel for securing protected area portals. The clarifications required were discussed with the security staff (details are considered Safeguards Information and exempt from public disclosure in accordance with 10 CFR 73.21). Results of the plan revision reviews will L

be addressed in separate correspondence.

,

c.

Conclusions j

i-Security procedures and records reviewed were complete and accurate. The need for clarification of part of a security plan revision was identified.

S4 Security and Safeguards Staff Knowledge and Performance a.

Insoection Scooe (81700)

The inspector toured various security posts and observed performance of security related duties. Security event logs and other records pertaining to security force performance were also reviewed.

b.

Observation and Findina

Security personnel interviewed and observed on post were aware of post responsibilities and procedure requirements, and familiar with the functional capabilities of security equipment located on their posts.

Protected area access for personnel, vehicles, and material were observed on two occasions during this inspection. No deficiencies were noted and procedural l

requirements were complied with.

Security event logs were accurate, completed within the time frame prescribed by regulations and well documented. Very conservative criteria was applied in determining

,

I which events to formally log in accordance with 10 CFR 73.71, c.

Conclusions

,

Security personnel were very knowledgeable of post requirements and responsibilities and no deficiencies were identified. Security event logs were complete and accurate.

S5 Security and Safeguards Staff Training and Qualification a.

Insoection Scope (81700)

Nine training records for members of the security force were reviewed. Weapon Qualification and familiarization courses of fire were observed for two security force members.

,

.

W

.~

s

.

b.

Observations and Findinas The inspector reviewed physical examination requirements, and other items, during review of nine security force training records. The physical security examination standards specifically stated that glaucoma was a disqualifying factor unless certain criteria was met. However, security personnel were not tested for glaucoma during the physical examination, and no tests conducted during the physical examination which would specifically indicate the presence of glaucoma. The unresolved item is: Does the licensee need to conduct tests for glaucoma when it is specficially identified as a potential disqualifying condition, even though there is no specific licensee commitment nor explicit regulatory requirement for the test? Resolution of this issue will be addressed by separate correspondence (URI 50-331/99006-01).

Weapon qualification and familiarization training for two security officers was observed at the onsite firing range. The personnel completing the course of fire attained a qualifying score, were familiar with the weapons being fired, and completed the course of fire in a safe manner. The range instructor conducted the weapon firing in a safe manner.

Conversely, soveral administrative deficiencies were noted to include:

Different minimum qualifying scores were identified in the Security Training and Qualification (T&Q) Plan for one qualification course.

The Individual Qualification Record used to record completion of critical job tasks had stress fire certification included as part of the task, but the course of fire is not identified in the T&Q plan standards for weapon qualification.

'

The range instructor was not familiar with the time limit imposed for some of the stages of one weapon's stress course of fire observed at the firing range by the inspector.

The procedure for the one stress course of fire required the weapon to be loaded and carried in the " port arm" position during the running part of the course.

However, during the observed training, the weapons were unloaded and in one case carried in the sling position during the running part of the course of fire.

Two different courses of fire were addressed by procedure for the one stress fire course.

The licensee security staff entered the noted deficiencies into their corrective action program. Actions to address the issue will be tracked and monitored under Action Request Form No.15433, dated June 10,1999.

Training records reviewed were complete and accurate and required training was completed within the specified time periods.

  • y

.

l c.

Conclusions Training records reviewed were complete and accurate. An unresolved item was l

identified in reference to testing security force members for glaucoma. Administrative deficiencies within the weapon training program were entered into the licensee's

'

corrective action program.

i S7 Quality Assurance in Security and Safeguards Activities

a.

Inspection Scope (81700)

The inspector reviewed self-assessment evaluations conducted by security staff and other personnel (licensee and contractor).

b.

Observations and Findinas The security self-assessment effort was varied and well documented. Quality Assurance audits for the fourth quarter of 1998 ( No. O-00/1-98-04, dated January 14,1999) and first quarter of 1999 (No. O-04/1-99-01, dated April 26,1999) were reviewed. The audit

,

results were well documented. The fourth quarter 1998 audit report noted that problem identification and resolution was proactive, and Action Requests (AR's) were used appropriately to address and correct problems identified. The audit report also addressed evaluation of a large scale security force drill, security staffing levels and training and qualification. No significant deficiencies were noted. The first quarter 1999 QA audit report did not specifically address physical protection requirements identified in 10 CFR 73.55.

Security procedure SD 1, "Self-Inspection Program," Revision 2, November 20,1995, describes the security section self-assessment program. Twelve completed Security Self-inspection Program Checklists addressing badges, communications, compensatory measures, duress alarms, gates, and other subjects were reviewed. Problems identified were monitored until resolved. During the inspector's observation of ingress into the protected area, the security staff conducted a drill involving attempted introduction of a prohibited item into the protected area. The item was detected and the security forces actions were prompt and appropriate. Such drills are conducted frequently and tracked and monitored by the security staff.

c.

Conclusions Self-assessment efforts were varied and effective in identifying and resolving problems.

S8 Miscellaneous Security and Safeguard issues S8.1 (Closed) Insoection Followuo item (Recort No. 50-331/98018-02): Inaccurate and incomplete Access Authorization record for a contractor employee because the individual failed to disclose some criminal history information on his personnel security questionnaire. We have completed our review of this issue and have determined that

.

-

u

.

.

the licensee security staff acted in a timely manner and complied with NRC requirements in reference to this issue.

S8.2 (Open) Unresolved item (Recort No. 50-331/98018-01h implementation and reporting of occasions when required armed responders were not immediately available. This issue is still being reviewed by NRC Headquarters. No further actions are required by the licensee security staff at this time.

I

l V. Manaaement Meetinas

'

- X1 Exit Meeting Summary

'

The inspector presented the inspection results to members of the licensee management at the conclusion of the inspection on June 11,1999. The personnel present acknowledged the findings presented. The inspector asked the licensee representatives whether any materials examined or inspection findings discussed during the exit meeting should be considered as proprietary or safeguards information. No proprietary or safeguards information was identified.

l

,

l

o

_.

[..

PARTIAL LIST OF PERSONS CONTACTED Licensee R. Anderson, Outage and Support Manager L

K. Berk, Quality Assurance Engineer S. Catron, Security Operations Supervisor

'

M; Duss, Security Specialist.

. D. Englehait, Security Supervisor

' B. Janowski Site Manager, Per Mar inc

_

D. Jantosik, Quality Assurance Manager J. Karrick, Nuclear Licensing Specialist l

l.

' D. Rickles, Security Specialist -

G.- Van Middleswworth, Plant Manager D. Wilson, Assistant Vice President-Nuclear NRC P. Prescott, NRC Region 111 Senior Resident inspector INSPECTION PROCEDURES USED IP 81700:

Physical Security Program for Power Reactor IP 92904:

Followup - Plant Suoport ITEMS OPENED, CLOSED, AND DISCUSSED Opened 50-331/99006-01 URI

. Need to Test Security Force Members for Glaucoma Closed 50-331/98018-02 ~

- IFl inaccurate and incomplete Access Authorization Record For a Contractor Employee Discussed

'50-331/98018-01 URI implementation and Reporting of Occasions 'Nhen Required Armed Responders Were Not immediately

~Available l

l

. " '

_

l*

PARTIAL LIST OF DOCUMENTS REVIEWED DAEC Security Directive SD-1, "Self-Inspection Program," Revision 2, November 20,1995 DAEC Security Directive SD-4, " Explosive detectors " Revision 13, April 14,1999 DAEC Security Directive SD-5, " Metal Detector," Revision 10, July 11,1998 DAEC Security Directive SD-7, "X-Ray inspection System," Revision 9, July 11,1995 DAEC Security Directive SD-8, "CAS/SAS Operations," Revision 34, September 24,1998 DAEC Security Directive SD-19, " Security Control Point Operations," Revision 6, September 18, 1997 DAEC Security Procedure SP-4, " Control of Personnel and Visitors," Revision 36, November 30, 1998 DAEC Security Procedure SP-5," Vehicle Access and Control," Revision 21, November 30,1998 DAEC Security Procedure SP-11," Reporting of Physical Security Events," Revision 20, February 4,1999 Evaluation Standard for Critical Task 27, Revision 4, March 9,1999 Instructor Guide No. IG 30006/50055.27 for 12 Gauge Shotgun, Revision 3, June 19,1997 Instructor Guide No. IG 30006/50055.26 for Handgun, Revision 4, February 27,1998 Security Event Reports From January 1,1999 to May 31,1999 Deinorte Security Systems Installation / Operation Manual for Sentrie Model HS-2S Metal / Weapon Detection System, Document No.14010015 Sentex Sensing Technology, Inc. Scanex/ Explosive Detector Instruction and Operation Manual

- EG&G Astrophysics Linescan System ten X-Ray inspection System Operation and Maintenance Manual Quality Assurance Quarterly Assessment Report, " Fourth Quarter,1998," No. O-00/1-98-04,

-

,

January 14,1999 Quality Assurance Quarterly Assessment Report, "First Quarter,1999," No. O-04/1-99-01,

. April 26,1999

_

l p.

..,

p'

'

it*

ps l-j

- Twelve Security Self-Inspection Program Checklists Addressing Badges, Communications,

' Compensatory Measures, Duress Alarms, Gates, and Other Subjects Eleven Security Action Request Forms for the Period Between January and May 1999 Nine Security Force Training and Qualification Records l-

,

d

,