JUL 24 199l Docket Nos. 50-259, 50-260, 50-296.

License Nos.

DPR-33, DPR-52, DPR-68 Tennessee Valley Authority ATTN:

Mr. D. A.

Nauman Senior Vice President, Nuclear Power 6N 38A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Gentlemen:

SUBJECT:

REPORT NOS. 50-259/91-18, 50-260/91-18, AND 50-296/91-18 Thank you for your response of July ll, 1991, to our Notice of Violation issued on June 1I, 1991, concerning activities conducted at your Browns Ferry facility.

We have evaluated your response and found that it meets the requirements of

CFR 2.201.

We will examine the implementation of your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely, cc:

M. Runyon, Chairman Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxville, TN 37902 J.

B. Waters, Director Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxvi1le, TN 37902 W. H. Kennoy, Director Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxville, TN 37902

,.(cq cont'd - See page 2)

91080h0328 910724 PDR ADQCK 05000259 Q

PDR Bruce A. Wilson, Chief TVA Projects

Tennessee Val 1ey Authority (cc cont'd)

W. F. Willis Senior Executive Officer

'T 12B 400 West Summit Hill Drive Knoxville, TN 37902 D. Nunn, Vice President Nuclear Projects Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Dr.

M. 0. Medford Vice President, Nuclear Assurance, Licensing and Fuels Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Chairman, Limestone County Commission P. 0.

Box 188 Athens, AL 35611.

0. J. Zeringue, Vice President, Browns Ferry Operations Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 E.

G. Wallace, Manager Nuclear Licensing and Regulatory Affairs Tennessee Valley Authority 5B Lookout Place Chattanooga, TN 37402-2801 P. Carier, Site Licensing Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 L.

W. Myers, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 (cc cont'd - See page 3)

Tennessee Valley Authority JUL 24 1891 bcc:

(cc cont'd)

TVA Representative Rockville Office 11921 Rockvil le Pike Suite 402 Rockville, MD 20852 General Counsel Tennessee Valley Authority ET 11H 400 West Summit Hill Drive Knoxvi1le, TN 37902 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, AL 36130 0.

D. Kingsley, Jr.

President, Generating Group Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 P. J. Kellogg, TVAP/RII B. Bordenick, OGC M. S. Callahan, GPA/CA R.

H. Bernhard, TVAP/RII T.

M. Ross, NRR S. Black, NRR Document Control Desk NRC Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 12, Box 637 Athens, AL 35611 4 07/p

RII:

RS CGUIRE 07/+$ 91 I-DRSS F10 07@ /91 RII: D PKEL OGG 07/gy/91