Category:INSPECTION REPORT
MONTHYEARIR 05000003/19980191999-03-0909 March 1999
[Table view]Insp Rept 50-003/98-19 on 981130-990222.No Violation Noted. Major Areas Inspected:Review of Facility Mgt & Control IR 05000247/19930261993-11-23023 November 1993 Insp Rept 50-247/93-26 on 931108-12.No Violations Noted. Major Areas Inspected:Mgt Support Plans,Protected & Vital Area Physical Barriers,Detection & Assessment Aids,Protected & Vital Area Access Control of Personnel IR 05000286/19930161993-10-19019 October 1993 Insp Rept 50-286/93-16 on 930802-06 & 0920-24.No Violations Noted.Major Areas Inspected:Isi Program,Procedures,Scope of ISI Work for Outage,Current Insp Plan & Testing Procedures IR 05000286/19930211993-09-17017 September 1993 Insp Rept 50-286/93-21 on 930830-0902.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected & Vital Area Physical Barriers,Detection & Assessment Aids & Protected Vital Area Access Control of Personnel ML20247B9531989-08-24024 August 1989 Enforcement Conference Rept 50-286/89-15 on 890808.Major Areas Discussed:Security Program During Spring 1989 Plant Outage IR 05000286/19890151989-07-24024 July 1989 Partially Withheld Physical Security Insp Rept 50-286/89-15 on 890605-07 (Ref 10CFR73.21).Violations Noted Re Physical Barriers,Vital Areas & Access Controls.Major Areas Inspected:Detection & Assessment Aids & Alarm Stations IR 05000286/19890031989-06-13013 June 1989 Enforcement Conference Rept 50-286/89-03 on 890428 in King of Prussia,Pa Re Findings of Insp Repts 50-286/89-03 & 50-286/88-22.Violations Noted.Areas Discussed:Security Program During Current Outage IR 05000286/19890051989-04-11011 April 1989 Partially Withheld Physical Security Insp Rept 50-286/89-05 on 890227-0303 (Ref 10CFR73.21).Violations & Noncompliances Noted.Major Areas inspected:non-routine Event,Mgt Support, Security Program Plans & Audits & Physical Barriers IR 05000247/19880121988-05-24024 May 1988 Physical Security Insp Rept 50-247/88-12 on 880407.No Noncompliance Noted.Major Areas Inspected:Program for Protection of Safeguards Info,Per 10CFR73.21,including Use of Required Storage Repositories & Handling Procedures IR 05000286/19880061988-05-19019 May 1988 Physical Security Insp Rept 50-286/88-06 on 880412-14.No Noncompliance Noted.Major Areas Inspected:Plan & Implementing Procedures,Organization,Program Audits,Testing & Maint,Physical Barriers & Security Sys Power Supply IR 05000286/19870131987-08-21021 August 1987 Safety Sys Outage Mod Insp Rept 50-286/87-13 on 870422-0714. Rept Describes Activities & Findings Associated W/First Portion of Team Insp Re Outage Design Insp IR 05000247/19870141987-06-0808 June 1987 Emergency Preparedness Insp Rept 50-247/87-14 on 870512-14. No Violations Identified.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 870513 IR 05000286/19870111987-05-14014 May 1987 Insp Rept 50-286/87-11 on 870420-24.No Violations Noted. Major Areas Inspected:Radiological Effluents Control Program,Mgt Controls,Air Cleaning Sys,Program Implementation & Previously Identified Items IR 05000286/19870091987-05-11011 May 1987 Insp Rept 50-286/87-09 on 870402-03.No Violations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting, Including Organization & Operating,Shipping & Receiving, Storage & Internal Control & Records & Repts IR 05000286/19870021987-03-18018 March 1987 Insp Rept 50-286/87-02 on 870127-29.No Violations Noted. Major Areas Inspected:Dosimetry Staffing & Training, Facilities & Equipment Procedures,Dose Assessment QA & Documentation & Recordkeeping IR 05000247/19870041987-03-16016 March 1987 Insp Rept 50-247/87-04 on 870203-0302.No Violations Noted. Major Areas Inspected:Routine Daily Insps,As Well as Unscheduled Backshift Insps of Onsite Activities,Operations, Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19870021987-03-10010 March 1987 Insp Rept 50-247/87-02 on 870127-29.Violation Noted:Failure to Include Acceptance Limits for Battery Electrolyte Temp & Failure to Ensure Battery Room Temp within Normal Bounds IR 05000286/19870011987-03-0505 March 1987 Insp Rept 50-286/87-01 on 870106-0217.Major Areas Inspected: Plant Operations Including Shift Logs & Records,Reactor Trips/Engineered Safeguards Actuation,Surveillance,Maint & Followup to Generic Ltr 83-28 & TMI Action Items IR 05000247/19870011987-02-26026 February 1987 Insp Rept 50-247/87-01 on 870106-0202.Violation Noted:No post-maint (Mod) Test Performed After Changing Location of Emergency Diesel Generator Svc Water Flow Indication & Control Instruments IR 05000286/19860241987-02-0909 February 1987 Insp Rept 50-286/86-24 on 861215-19.Violation Noted:Raychem Splices Identified W/Less than Required 2-inch Overlap & Bending Radii Less than Allowed IR 05000247/19860331987-01-27027 January 1987 Radiation Protection Insp Rept 50-247/86-33 on 861215-19.No Violations Noted.Major Areas Inspected:Alara,Internal Exposure Control & External Exposure Control IR 05000247/19861361987-01-21021 January 1987 Meeting Rept 50-247/86-136 on 861209.Major Items Discussed: Plans for Integrated Assessment of Auxiliary Feedwater Sys. Mods Being Considered Include Providing Direct Indication of Overspeed Trip Mechanism Status in Control Room IR 05000286/19860231987-01-15015 January 1987 Onsite Regular & Backshift Insp Rept 50-286/86-23 on 861118- 870105.Violation Noted:Failure to Follow Administrative Procedures AP-6 & AP-25-3 Re Work Requests & Matl Substitutions,Respectively IR 05000247/19860321987-01-13013 January 1987 Insp Rept 50-247/86-32 on 861122-870105.No Violations Noted. Major Areas Inspected:Licensee Actions on Previously Identified Insp Findings,Operations,Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19860301987-01-0707 January 1987 Partially Withheld Physical Security Insp Rept 50-247/86-30 on 861117-21 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures, Security Organization & Assessment Aids IR 05000247/19860281986-12-23023 December 1986 Insp Rept 50-247/86-28 on 861014-1121.Violation Noted: Failure to Perform Test Confirming That Mod Produced Expected Results & That Mod Did Not Reduce Safety of Operations IR 05000247/19860261986-09-22022 September 1986 Insp Rept 50-247/86-26 on 860826-28.Major Areas Inspected: Requalification & Initial Licensing Training Programs for Licensed Operators.No Tracking Sys for Assuring Compliance w/10CFR55.31(e) Requirements IR 05000247/19860171986-08-0505 August 1986 Health Physics Appraisal Rept 50-247/86-17 on 860616-20.No Violations Noted.Major Areas Inspected:Radiation Controls Program,Developed Per NRC 840927 Order Modifying License, Including ALARA & High Radiation Area Control IR 05000247/19860131986-07-0909 July 1986 Emergency Preparedness Insp Rept 50-247/86-13 on 860604.No Violations Noted.Major Areas inspected:full-participation Emergency Exercise IR 05000286/19860061986-04-15015 April 1986 Emergency Preparedness Insp Rept 50-286/86-06 on 860311-13. No Violations Identified.Major Areas Inspected:Observation of Annual Emergency Exercise on 860312 IR 05000247/19860011986-04-11011 April 1986 Mgt Meeting Rept 50-247/86-01 on 860320.Violation Noted: Environ Health & Safety Personnel Not Trained in Responsibilities for QC & QC Responsibilities Inadequately Specified IR 05000247/19860091986-04-0808 April 1986 Insp Rept 50-247/86-09 on 860304-31.Insp Identified Two Unresolved Items Re Environ Qualification.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings,Ler Followup,Fire Protection & Plant Security IR 05000286/19860041986-04-0303 April 1986 Insp Rept 50-286/86-04 on 860303-06.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Measurement Control,Analytical Procedure Evaluations & Training IR 05000247/19860021986-03-11011 March 1986 Enforcement Conference Rept 50-247/86-02 on 860213.Major Areas Discussed:Violations Noted in Insp Rept 50-247/86-02 & Corrective Actions Taken IR 05000247/19850141985-06-21021 June 1985 Emergency Preparedness Insp Rept 50-247/85-14 on 850604-06. No Violation or Deviation Noted.Major Areas Inspected: Observation of Licensee Annual Emergency Exercise Performed on 850605 IR 05000286/19820101982-07-29029 July 1982 IE Insp Rept 50-286/82-10 on 820616-0715.No Noncompliance Noted.Major Areas Inspected:Shift Logs & Records,Action on Previous Findings,Audits,Loss of Offsite Power & Followup on IE Bulletins IR 05000286/19820021982-07-22022 July 1982 IE Emergency Preparedness Appraisal Rept 50-286/82-02 on 820208-11.No Noncompliance Noted.Major Areas Inspected: Followup of Emergency Preparedness Items from Prior Appraisal on 810511-20 IR 05000286/19820091982-07-0101 July 1982 IE Insp Rept 50-286/82-09 on 820601-04.Noncompliance Noted: Failure to Install Sprinkler Head Specified Per Natl Fire Protection Assoc Code 15,1977 IR 05000003/19820011982-06-29029 June 1982 Revised IE Insp Repts 50-003/82-01 & 50-247/82-02 on 820208- 11.No Noncompliance Noted.Major Areas Inspected:Followup of Emergency Preparedness Items from 810511-20 Appraisal.Rept Includes Revised Page 22 IR 05000286/19820081982-06-28028 June 1982 IE Insp Rept 50-286/82-08 on 820516-0615.Noncompliance Noted:On 820527,solid Radwaste Operations Using Baling Machine Conducted W/O Following Written Procedure & Shroud Door Not Closed as Required During Operation IR 05000247/19820101982-06-24024 June 1982 IE Insp Rept 50-247/82-10 on 820524-28.Noncompliance Noted: Failure to Follow Field Const Procedures & Inadequate Design Interface Control ML20054L0501982-06-15015 June 1982 IE Insp Rept 50-247/82-09 on 820501-31.Noncompliance Noted:Failure to Revise Procedures to Include Mod to Operational Protection Sys Setpoints Completed in Mar 1981 IR 05000247/19820081982-05-20020 May 1982 IE Insp Rept 50-247/82-08 on 820503-07.No Noncompliance Noted.Major Areas Inspected:Fire Protection/Prevention Program,Completion of Fire Hazards Analysis Commitments & SER Commitments ML20062D8201978-10-19019 October 1978 IE Inspec Rept 50-247/78-30 on 780913-14 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Licensee Response to IE Circular 78-08 Environ Qual of Safety Related Elec Equip IR 05000247/19780281978-09-14014 September 1978 IE Inspec Rept 50-247/78-28 on 780825 During Which No Items of Noncompliance Were Noted.Major Areas Inspec Incl: Previously Identified Unresolved Items W/Respect to Records 1999-03-09 Category:NRC-GENERATED MONTHYEARIR 05000003/19980191999-03-0909 March 1999
[Table view]Insp Rept 50-003/98-19 on 981130-990222.No Violation Noted. Major Areas Inspected:Review of Facility Mgt & Control IR 05000247/19930261993-11-23023 November 1993 Insp Rept 50-247/93-26 on 931108-12.No Violations Noted. Major Areas Inspected:Mgt Support Plans,Protected & Vital Area Physical Barriers,Detection & Assessment Aids,Protected & Vital Area Access Control of Personnel IR 05000286/19930161993-10-19019 October 1993 Insp Rept 50-286/93-16 on 930802-06 & 0920-24.No Violations Noted.Major Areas Inspected:Isi Program,Procedures,Scope of ISI Work for Outage,Current Insp Plan & Testing Procedures IR 05000286/19930211993-09-17017 September 1993 Insp Rept 50-286/93-21 on 930830-0902.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected & Vital Area Physical Barriers,Detection & Assessment Aids & Protected Vital Area Access Control of Personnel ML20247B9531989-08-24024 August 1989 Enforcement Conference Rept 50-286/89-15 on 890808.Major Areas Discussed:Security Program During Spring 1989 Plant Outage IR 05000286/19890151989-07-24024 July 1989 Partially Withheld Physical Security Insp Rept 50-286/89-15 on 890605-07 (Ref 10CFR73.21).Violations Noted Re Physical Barriers,Vital Areas & Access Controls.Major Areas Inspected:Detection & Assessment Aids & Alarm Stations IR 05000286/19890031989-06-13013 June 1989 Enforcement Conference Rept 50-286/89-03 on 890428 in King of Prussia,Pa Re Findings of Insp Repts 50-286/89-03 & 50-286/88-22.Violations Noted.Areas Discussed:Security Program During Current Outage IR 05000286/19890051989-04-11011 April 1989 Partially Withheld Physical Security Insp Rept 50-286/89-05 on 890227-0303 (Ref 10CFR73.21).Violations & Noncompliances Noted.Major Areas inspected:non-routine Event,Mgt Support, Security Program Plans & Audits & Physical Barriers IR 05000247/19880121988-05-24024 May 1988 Physical Security Insp Rept 50-247/88-12 on 880407.No Noncompliance Noted.Major Areas Inspected:Program for Protection of Safeguards Info,Per 10CFR73.21,including Use of Required Storage Repositories & Handling Procedures IR 05000286/19880061988-05-19019 May 1988 Physical Security Insp Rept 50-286/88-06 on 880412-14.No Noncompliance Noted.Major Areas Inspected:Plan & Implementing Procedures,Organization,Program Audits,Testing & Maint,Physical Barriers & Security Sys Power Supply IR 05000286/19870131987-08-21021 August 1987 Safety Sys Outage Mod Insp Rept 50-286/87-13 on 870422-0714. Rept Describes Activities & Findings Associated W/First Portion of Team Insp Re Outage Design Insp IR 05000247/19870141987-06-0808 June 1987 Emergency Preparedness Insp Rept 50-247/87-14 on 870512-14. No Violations Identified.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 870513 IR 05000286/19870111987-05-14014 May 1987 Insp Rept 50-286/87-11 on 870420-24.No Violations Noted. Major Areas Inspected:Radiological Effluents Control Program,Mgt Controls,Air Cleaning Sys,Program Implementation & Previously Identified Items IR 05000286/19870091987-05-11011 May 1987 Insp Rept 50-286/87-09 on 870402-03.No Violations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting, Including Organization & Operating,Shipping & Receiving, Storage & Internal Control & Records & Repts IR 05000286/19870021987-03-18018 March 1987 Insp Rept 50-286/87-02 on 870127-29.No Violations Noted. Major Areas Inspected:Dosimetry Staffing & Training, Facilities & Equipment Procedures,Dose Assessment QA & Documentation & Recordkeeping IR 05000247/19870041987-03-16016 March 1987 Insp Rept 50-247/87-04 on 870203-0302.No Violations Noted. Major Areas Inspected:Routine Daily Insps,As Well as Unscheduled Backshift Insps of Onsite Activities,Operations, Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19870021987-03-10010 March 1987 Insp Rept 50-247/87-02 on 870127-29.Violation Noted:Failure to Include Acceptance Limits for Battery Electrolyte Temp & Failure to Ensure Battery Room Temp within Normal Bounds IR 05000286/19870011987-03-0505 March 1987 Insp Rept 50-286/87-01 on 870106-0217.Major Areas Inspected: Plant Operations Including Shift Logs & Records,Reactor Trips/Engineered Safeguards Actuation,Surveillance,Maint & Followup to Generic Ltr 83-28 & TMI Action Items IR 05000247/19870011987-02-26026 February 1987 Insp Rept 50-247/87-01 on 870106-0202.Violation Noted:No post-maint (Mod) Test Performed After Changing Location of Emergency Diesel Generator Svc Water Flow Indication & Control Instruments IR 05000286/19860241987-02-0909 February 1987 Insp Rept 50-286/86-24 on 861215-19.Violation Noted:Raychem Splices Identified W/Less than Required 2-inch Overlap & Bending Radii Less than Allowed IR 05000247/19860331987-01-27027 January 1987 Radiation Protection Insp Rept 50-247/86-33 on 861215-19.No Violations Noted.Major Areas Inspected:Alara,Internal Exposure Control & External Exposure Control IR 05000247/19861361987-01-21021 January 1987 Meeting Rept 50-247/86-136 on 861209.Major Items Discussed: Plans for Integrated Assessment of Auxiliary Feedwater Sys. Mods Being Considered Include Providing Direct Indication of Overspeed Trip Mechanism Status in Control Room IR 05000286/19860231987-01-15015 January 1987 Onsite Regular & Backshift Insp Rept 50-286/86-23 on 861118- 870105.Violation Noted:Failure to Follow Administrative Procedures AP-6 & AP-25-3 Re Work Requests & Matl Substitutions,Respectively IR 05000247/19860321987-01-13013 January 1987 Insp Rept 50-247/86-32 on 861122-870105.No Violations Noted. Major Areas Inspected:Licensee Actions on Previously Identified Insp Findings,Operations,Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19860301987-01-0707 January 1987 Partially Withheld Physical Security Insp Rept 50-247/86-30 on 861117-21 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures, Security Organization & Assessment Aids IR 05000247/19860281986-12-23023 December 1986 Insp Rept 50-247/86-28 on 861014-1121.Violation Noted: Failure to Perform Test Confirming That Mod Produced Expected Results & That Mod Did Not Reduce Safety of Operations IR 05000247/19860261986-09-22022 September 1986 Insp Rept 50-247/86-26 on 860826-28.Major Areas Inspected: Requalification & Initial Licensing Training Programs for Licensed Operators.No Tracking Sys for Assuring Compliance w/10CFR55.31(e) Requirements IR 05000247/19860171986-08-0505 August 1986 Health Physics Appraisal Rept 50-247/86-17 on 860616-20.No Violations Noted.Major Areas Inspected:Radiation Controls Program,Developed Per NRC 840927 Order Modifying License, Including ALARA & High Radiation Area Control IR 05000247/19860131986-07-0909 July 1986 Emergency Preparedness Insp Rept 50-247/86-13 on 860604.No Violations Noted.Major Areas inspected:full-participation Emergency Exercise IR 05000286/19860061986-04-15015 April 1986 Emergency Preparedness Insp Rept 50-286/86-06 on 860311-13. No Violations Identified.Major Areas Inspected:Observation of Annual Emergency Exercise on 860312 IR 05000247/19860011986-04-11011 April 1986 Mgt Meeting Rept 50-247/86-01 on 860320.Violation Noted: Environ Health & Safety Personnel Not Trained in Responsibilities for QC & QC Responsibilities Inadequately Specified IR 05000247/19860091986-04-0808 April 1986 Insp Rept 50-247/86-09 on 860304-31.Insp Identified Two Unresolved Items Re Environ Qualification.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings,Ler Followup,Fire Protection & Plant Security IR 05000286/19860041986-04-0303 April 1986 Insp Rept 50-286/86-04 on 860303-06.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Measurement Control,Analytical Procedure Evaluations & Training IR 05000247/19860021986-03-11011 March 1986 Enforcement Conference Rept 50-247/86-02 on 860213.Major Areas Discussed:Violations Noted in Insp Rept 50-247/86-02 & Corrective Actions Taken IR 05000247/19850141985-06-21021 June 1985 Emergency Preparedness Insp Rept 50-247/85-14 on 850604-06. No Violation or Deviation Noted.Major Areas Inspected: Observation of Licensee Annual Emergency Exercise Performed on 850605 IR 05000286/19820101982-07-29029 July 1982 IE Insp Rept 50-286/82-10 on 820616-0715.No Noncompliance Noted.Major Areas Inspected:Shift Logs & Records,Action on Previous Findings,Audits,Loss of Offsite Power & Followup on IE Bulletins IR 05000286/19820021982-07-22022 July 1982 IE Emergency Preparedness Appraisal Rept 50-286/82-02 on 820208-11.No Noncompliance Noted.Major Areas Inspected: Followup of Emergency Preparedness Items from Prior Appraisal on 810511-20 IR 05000286/19820091982-07-0101 July 1982 IE Insp Rept 50-286/82-09 on 820601-04.Noncompliance Noted: Failure to Install Sprinkler Head Specified Per Natl Fire Protection Assoc Code 15,1977 IR 05000003/19820011982-06-29029 June 1982 Revised IE Insp Repts 50-003/82-01 & 50-247/82-02 on 820208- 11.No Noncompliance Noted.Major Areas Inspected:Followup of Emergency Preparedness Items from 810511-20 Appraisal.Rept Includes Revised Page 22 IR 05000286/19820081982-06-28028 June 1982 IE Insp Rept 50-286/82-08 on 820516-0615.Noncompliance Noted:On 820527,solid Radwaste Operations Using Baling Machine Conducted W/O Following Written Procedure & Shroud Door Not Closed as Required During Operation IR 05000247/19820101982-06-24024 June 1982 IE Insp Rept 50-247/82-10 on 820524-28.Noncompliance Noted: Failure to Follow Field Const Procedures & Inadequate Design Interface Control ML20054L0501982-06-15015 June 1982 IE Insp Rept 50-247/82-09 on 820501-31.Noncompliance Noted:Failure to Revise Procedures to Include Mod to Operational Protection Sys Setpoints Completed in Mar 1981 IR 05000247/19820081982-05-20020 May 1982 IE Insp Rept 50-247/82-08 on 820503-07.No Noncompliance Noted.Major Areas Inspected:Fire Protection/Prevention Program,Completion of Fire Hazards Analysis Commitments & SER Commitments ML20062D8201978-10-19019 October 1978 IE Inspec Rept 50-247/78-30 on 780913-14 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Licensee Response to IE Circular 78-08 Environ Qual of Safety Related Elec Equip IR 05000247/19780281978-09-14014 September 1978 IE Inspec Rept 50-247/78-28 on 780825 During Which No Items of Noncompliance Were Noted.Major Areas Inspec Incl: Previously Identified Unresolved Items W/Respect to Records 1999-03-09 Category:INSPECTION REPORT MONTHYEARIR 05000003/19980191999-03-0909 March 1999
[Table view]Insp Rept 50-003/98-19 on 981130-990222.No Violation Noted. Major Areas Inspected:Review of Facility Mgt & Control IR 05000247/19930261993-11-23023 November 1993 Insp Rept 50-247/93-26 on 931108-12.No Violations Noted. Major Areas Inspected:Mgt Support Plans,Protected & Vital Area Physical Barriers,Detection & Assessment Aids,Protected & Vital Area Access Control of Personnel IR 05000286/19930161993-10-19019 October 1993 Insp Rept 50-286/93-16 on 930802-06 & 0920-24.No Violations Noted.Major Areas Inspected:Isi Program,Procedures,Scope of ISI Work for Outage,Current Insp Plan & Testing Procedures IR 05000286/19930211993-09-17017 September 1993 Insp Rept 50-286/93-21 on 930830-0902.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected & Vital Area Physical Barriers,Detection & Assessment Aids & Protected Vital Area Access Control of Personnel ML20247B9531989-08-24024 August 1989 Enforcement Conference Rept 50-286/89-15 on 890808.Major Areas Discussed:Security Program During Spring 1989 Plant Outage IR 05000286/19890151989-07-24024 July 1989 Partially Withheld Physical Security Insp Rept 50-286/89-15 on 890605-07 (Ref 10CFR73.21).Violations Noted Re Physical Barriers,Vital Areas & Access Controls.Major Areas Inspected:Detection & Assessment Aids & Alarm Stations IR 05000286/19890031989-06-13013 June 1989 Enforcement Conference Rept 50-286/89-03 on 890428 in King of Prussia,Pa Re Findings of Insp Repts 50-286/89-03 & 50-286/88-22.Violations Noted.Areas Discussed:Security Program During Current Outage IR 05000286/19890051989-04-11011 April 1989 Partially Withheld Physical Security Insp Rept 50-286/89-05 on 890227-0303 (Ref 10CFR73.21).Violations & Noncompliances Noted.Major Areas inspected:non-routine Event,Mgt Support, Security Program Plans & Audits & Physical Barriers IR 05000247/19880121988-05-24024 May 1988 Physical Security Insp Rept 50-247/88-12 on 880407.No Noncompliance Noted.Major Areas Inspected:Program for Protection of Safeguards Info,Per 10CFR73.21,including Use of Required Storage Repositories & Handling Procedures IR 05000286/19880061988-05-19019 May 1988 Physical Security Insp Rept 50-286/88-06 on 880412-14.No Noncompliance Noted.Major Areas Inspected:Plan & Implementing Procedures,Organization,Program Audits,Testing & Maint,Physical Barriers & Security Sys Power Supply IR 05000286/19870131987-08-21021 August 1987 Safety Sys Outage Mod Insp Rept 50-286/87-13 on 870422-0714. Rept Describes Activities & Findings Associated W/First Portion of Team Insp Re Outage Design Insp IR 05000247/19870141987-06-0808 June 1987 Emergency Preparedness Insp Rept 50-247/87-14 on 870512-14. No Violations Identified.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 870513 IR 05000286/19870111987-05-14014 May 1987 Insp Rept 50-286/87-11 on 870420-24.No Violations Noted. Major Areas Inspected:Radiological Effluents Control Program,Mgt Controls,Air Cleaning Sys,Program Implementation & Previously Identified Items IR 05000286/19870091987-05-11011 May 1987 Insp Rept 50-286/87-09 on 870402-03.No Violations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting, Including Organization & Operating,Shipping & Receiving, Storage & Internal Control & Records & Repts IR 05000286/19870021987-03-18018 March 1987 Insp Rept 50-286/87-02 on 870127-29.No Violations Noted. Major Areas Inspected:Dosimetry Staffing & Training, Facilities & Equipment Procedures,Dose Assessment QA & Documentation & Recordkeeping IR 05000247/19870041987-03-16016 March 1987 Insp Rept 50-247/87-04 on 870203-0302.No Violations Noted. Major Areas Inspected:Routine Daily Insps,As Well as Unscheduled Backshift Insps of Onsite Activities,Operations, Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19870021987-03-10010 March 1987 Insp Rept 50-247/87-02 on 870127-29.Violation Noted:Failure to Include Acceptance Limits for Battery Electrolyte Temp & Failure to Ensure Battery Room Temp within Normal Bounds IR 05000286/19870011987-03-0505 March 1987 Insp Rept 50-286/87-01 on 870106-0217.Major Areas Inspected: Plant Operations Including Shift Logs & Records,Reactor Trips/Engineered Safeguards Actuation,Surveillance,Maint & Followup to Generic Ltr 83-28 & TMI Action Items IR 05000247/19870011987-02-26026 February 1987 Insp Rept 50-247/87-01 on 870106-0202.Violation Noted:No post-maint (Mod) Test Performed After Changing Location of Emergency Diesel Generator Svc Water Flow Indication & Control Instruments IR 05000286/19860241987-02-0909 February 1987 Insp Rept 50-286/86-24 on 861215-19.Violation Noted:Raychem Splices Identified W/Less than Required 2-inch Overlap & Bending Radii Less than Allowed IR 05000247/19860331987-01-27027 January 1987 Radiation Protection Insp Rept 50-247/86-33 on 861215-19.No Violations Noted.Major Areas Inspected:Alara,Internal Exposure Control & External Exposure Control IR 05000247/19861361987-01-21021 January 1987 Meeting Rept 50-247/86-136 on 861209.Major Items Discussed: Plans for Integrated Assessment of Auxiliary Feedwater Sys. Mods Being Considered Include Providing Direct Indication of Overspeed Trip Mechanism Status in Control Room IR 05000286/19860231987-01-15015 January 1987 Onsite Regular & Backshift Insp Rept 50-286/86-23 on 861118- 870105.Violation Noted:Failure to Follow Administrative Procedures AP-6 & AP-25-3 Re Work Requests & Matl Substitutions,Respectively IR 05000247/19860321987-01-13013 January 1987 Insp Rept 50-247/86-32 on 861122-870105.No Violations Noted. Major Areas Inspected:Licensee Actions on Previously Identified Insp Findings,Operations,Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19860301987-01-0707 January 1987 Partially Withheld Physical Security Insp Rept 50-247/86-30 on 861117-21 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures, Security Organization & Assessment Aids IR 05000247/19860281986-12-23023 December 1986 Insp Rept 50-247/86-28 on 861014-1121.Violation Noted: Failure to Perform Test Confirming That Mod Produced Expected Results & That Mod Did Not Reduce Safety of Operations IR 05000247/19860261986-09-22022 September 1986 Insp Rept 50-247/86-26 on 860826-28.Major Areas Inspected: Requalification & Initial Licensing Training Programs for Licensed Operators.No Tracking Sys for Assuring Compliance w/10CFR55.31(e) Requirements IR 05000247/19860171986-08-0505 August 1986 Health Physics Appraisal Rept 50-247/86-17 on 860616-20.No Violations Noted.Major Areas Inspected:Radiation Controls Program,Developed Per NRC 840927 Order Modifying License, Including ALARA & High Radiation Area Control IR 05000247/19860131986-07-0909 July 1986 Emergency Preparedness Insp Rept 50-247/86-13 on 860604.No Violations Noted.Major Areas inspected:full-participation Emergency Exercise IR 05000286/19860061986-04-15015 April 1986 Emergency Preparedness Insp Rept 50-286/86-06 on 860311-13. No Violations Identified.Major Areas Inspected:Observation of Annual Emergency Exercise on 860312 IR 05000247/19860011986-04-11011 April 1986 Mgt Meeting Rept 50-247/86-01 on 860320.Violation Noted: Environ Health & Safety Personnel Not Trained in Responsibilities for QC & QC Responsibilities Inadequately Specified IR 05000247/19860091986-04-0808 April 1986 Insp Rept 50-247/86-09 on 860304-31.Insp Identified Two Unresolved Items Re Environ Qualification.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings,Ler Followup,Fire Protection & Plant Security IR 05000286/19860041986-04-0303 April 1986 Insp Rept 50-286/86-04 on 860303-06.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Measurement Control,Analytical Procedure Evaluations & Training IR 05000247/19860021986-03-11011 March 1986 Enforcement Conference Rept 50-247/86-02 on 860213.Major Areas Discussed:Violations Noted in Insp Rept 50-247/86-02 & Corrective Actions Taken IR 05000247/19850141985-06-21021 June 1985 Emergency Preparedness Insp Rept 50-247/85-14 on 850604-06. No Violation or Deviation Noted.Major Areas Inspected: Observation of Licensee Annual Emergency Exercise Performed on 850605 IR 05000286/19820101982-07-29029 July 1982 IE Insp Rept 50-286/82-10 on 820616-0715.No Noncompliance Noted.Major Areas Inspected:Shift Logs & Records,Action on Previous Findings,Audits,Loss of Offsite Power & Followup on IE Bulletins IR 05000286/19820021982-07-22022 July 1982 IE Emergency Preparedness Appraisal Rept 50-286/82-02 on 820208-11.No Noncompliance Noted.Major Areas Inspected: Followup of Emergency Preparedness Items from Prior Appraisal on 810511-20 IR 05000286/19820091982-07-0101 July 1982 IE Insp Rept 50-286/82-09 on 820601-04.Noncompliance Noted: Failure to Install Sprinkler Head Specified Per Natl Fire Protection Assoc Code 15,1977 IR 05000003/19820011982-06-29029 June 1982 Revised IE Insp Repts 50-003/82-01 & 50-247/82-02 on 820208- 11.No Noncompliance Noted.Major Areas Inspected:Followup of Emergency Preparedness Items from 810511-20 Appraisal.Rept Includes Revised Page 22 IR 05000286/19820081982-06-28028 June 1982 IE Insp Rept 50-286/82-08 on 820516-0615.Noncompliance Noted:On 820527,solid Radwaste Operations Using Baling Machine Conducted W/O Following Written Procedure & Shroud Door Not Closed as Required During Operation IR 05000247/19820101982-06-24024 June 1982 IE Insp Rept 50-247/82-10 on 820524-28.Noncompliance Noted: Failure to Follow Field Const Procedures & Inadequate Design Interface Control ML20054L0501982-06-15015 June 1982 IE Insp Rept 50-247/82-09 on 820501-31.Noncompliance Noted:Failure to Revise Procedures to Include Mod to Operational Protection Sys Setpoints Completed in Mar 1981 IR 05000247/19820081982-05-20020 May 1982 IE Insp Rept 50-247/82-08 on 820503-07.No Noncompliance Noted.Major Areas Inspected:Fire Protection/Prevention Program,Completion of Fire Hazards Analysis Commitments & SER Commitments ML20062D8201978-10-19019 October 1978 IE Inspec Rept 50-247/78-30 on 780913-14 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Licensee Response to IE Circular 78-08 Environ Qual of Safety Related Elec Equip IR 05000247/19780281978-09-14014 September 1978 IE Inspec Rept 50-247/78-28 on 780825 During Which No Items of Noncompliance Were Noted.Major Areas Inspec Incl: Previously Identified Unresolved Items W/Respect to Records 1999-03-09 Category:UTILITY MONTHYEARML20247B9531989-08-24024 August 1989
[Table view]Enforcement Conference Rept 50-286/89-15 on 890808.Major Areas Discussed:Security Program During Spring 1989 Plant Outage IR 05000286/19890151989-07-24024 July 1989 Partially Withheld Physical Security Insp Rept 50-286/89-15 on 890605-07 (Ref 10CFR73.21).Violations Noted Re Physical Barriers,Vital Areas & Access Controls.Major Areas Inspected:Detection & Assessment Aids & Alarm Stations IR 05000286/19890031989-06-13013 June 1989 Enforcement Conference Rept 50-286/89-03 on 890428 in King of Prussia,Pa Re Findings of Insp Repts 50-286/89-03 & 50-286/88-22.Violations Noted.Areas Discussed:Security Program During Current Outage IR 05000286/19890051989-04-11011 April 1989 Partially Withheld Physical Security Insp Rept 50-286/89-05 on 890227-0303 (Ref 10CFR73.21).Violations & Noncompliances Noted.Major Areas inspected:non-routine Event,Mgt Support, Security Program Plans & Audits & Physical Barriers IR 05000247/19880121988-05-24024 May 1988 Physical Security Insp Rept 50-247/88-12 on 880407.No Noncompliance Noted.Major Areas Inspected:Program for Protection of Safeguards Info,Per 10CFR73.21,including Use of Required Storage Repositories & Handling Procedures IR 05000286/19880061988-05-19019 May 1988 Physical Security Insp Rept 50-286/88-06 on 880412-14.No Noncompliance Noted.Major Areas Inspected:Plan & Implementing Procedures,Organization,Program Audits,Testing & Maint,Physical Barriers & Security Sys Power Supply IR 05000286/19870131987-08-21021 August 1987 Safety Sys Outage Mod Insp Rept 50-286/87-13 on 870422-0714. Rept Describes Activities & Findings Associated W/First Portion of Team Insp Re Outage Design Insp IR 05000247/19870141987-06-0808 June 1987 Emergency Preparedness Insp Rept 50-247/87-14 on 870512-14. No Violations Identified.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 870513 IR 05000286/19870111987-05-14014 May 1987 Insp Rept 50-286/87-11 on 870420-24.No Violations Noted. Major Areas Inspected:Radiological Effluents Control Program,Mgt Controls,Air Cleaning Sys,Program Implementation & Previously Identified Items IR 05000286/19870091987-05-11011 May 1987 Insp Rept 50-286/87-09 on 870402-03.No Violations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting, Including Organization & Operating,Shipping & Receiving, Storage & Internal Control & Records & Repts IR 05000286/19870021987-03-18018 March 1987 Insp Rept 50-286/87-02 on 870127-29.No Violations Noted. Major Areas Inspected:Dosimetry Staffing & Training, Facilities & Equipment Procedures,Dose Assessment QA & Documentation & Recordkeeping IR 05000247/19870041987-03-16016 March 1987 Insp Rept 50-247/87-04 on 870203-0302.No Violations Noted. Major Areas Inspected:Routine Daily Insps,As Well as Unscheduled Backshift Insps of Onsite Activities,Operations, Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19870021987-03-10010 March 1987 Insp Rept 50-247/87-02 on 870127-29.Violation Noted:Failure to Include Acceptance Limits for Battery Electrolyte Temp & Failure to Ensure Battery Room Temp within Normal Bounds IR 05000286/19870011987-03-0505 March 1987 Insp Rept 50-286/87-01 on 870106-0217.Major Areas Inspected: Plant Operations Including Shift Logs & Records,Reactor Trips/Engineered Safeguards Actuation,Surveillance,Maint & Followup to Generic Ltr 83-28 & TMI Action Items IR 05000247/19870011987-02-26026 February 1987 Insp Rept 50-247/87-01 on 870106-0202.Violation Noted:No post-maint (Mod) Test Performed After Changing Location of Emergency Diesel Generator Svc Water Flow Indication & Control Instruments IR 05000286/19860241987-02-0909 February 1987 Insp Rept 50-286/86-24 on 861215-19.Violation Noted:Raychem Splices Identified W/Less than Required 2-inch Overlap & Bending Radii Less than Allowed IR 05000247/19860331987-01-27027 January 1987 Radiation Protection Insp Rept 50-247/86-33 on 861215-19.No Violations Noted.Major Areas Inspected:Alara,Internal Exposure Control & External Exposure Control IR 05000247/19861361987-01-21021 January 1987 Meeting Rept 50-247/86-136 on 861209.Major Items Discussed: Plans for Integrated Assessment of Auxiliary Feedwater Sys. Mods Being Considered Include Providing Direct Indication of Overspeed Trip Mechanism Status in Control Room IR 05000286/19860231987-01-15015 January 1987 Onsite Regular & Backshift Insp Rept 50-286/86-23 on 861118- 870105.Violation Noted:Failure to Follow Administrative Procedures AP-6 & AP-25-3 Re Work Requests & Matl Substitutions,Respectively IR 05000247/19860321987-01-13013 January 1987 Insp Rept 50-247/86-32 on 861122-870105.No Violations Noted. Major Areas Inspected:Licensee Actions on Previously Identified Insp Findings,Operations,Maint,Surveillance & Review of Periodic & Special Repts IR 05000247/19860301987-01-0707 January 1987 Partially Withheld Physical Security Insp Rept 50-247/86-30 on 861117-21 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures, Security Organization & Assessment Aids IR 05000247/19860281986-12-23023 December 1986 Insp Rept 50-247/86-28 on 861014-1121.Violation Noted: Failure to Perform Test Confirming That Mod Produced Expected Results & That Mod Did Not Reduce Safety of Operations IR 05000247/19860171986-08-0505 August 1986 Health Physics Appraisal Rept 50-247/86-17 on 860616-20.No Violations Noted.Major Areas Inspected:Radiation Controls Program,Developed Per NRC 840927 Order Modifying License, Including ALARA & High Radiation Area Control IR 05000247/19860131986-07-0909 July 1986 Emergency Preparedness Insp Rept 50-247/86-13 on 860604.No Violations Noted.Major Areas inspected:full-participation Emergency Exercise IR 05000286/19860061986-04-15015 April 1986 Emergency Preparedness Insp Rept 50-286/86-06 on 860311-13. No Violations Identified.Major Areas Inspected:Observation of Annual Emergency Exercise on 860312 IR 05000247/19860011986-04-11011 April 1986 Mgt Meeting Rept 50-247/86-01 on 860320.Violation Noted: Environ Health & Safety Personnel Not Trained in Responsibilities for QC & QC Responsibilities Inadequately Specified IR 05000247/19860091986-04-0808 April 1986 Insp Rept 50-247/86-09 on 860304-31.Insp Identified Two Unresolved Items Re Environ Qualification.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings,Ler Followup,Fire Protection & Plant Security IR 05000286/19860041986-04-0303 April 1986 Insp Rept 50-286/86-04 on 860303-06.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Measurement Control,Analytical Procedure Evaluations & Training IR 05000247/19860021986-03-11011 March 1986 Enforcement Conference Rept 50-247/86-02 on 860213.Major Areas Discussed:Violations Noted in Insp Rept 50-247/86-02 & Corrective Actions Taken IR 05000247/19850141985-06-21021 June 1985 Emergency Preparedness Insp Rept 50-247/85-14 on 850604-06. No Violation or Deviation Noted.Major Areas Inspected: Observation of Licensee Annual Emergency Exercise Performed on 850605 IR 05000286/19820021982-07-22022 July 1982 IE Emergency Preparedness Appraisal Rept 50-286/82-02 on 820208-11.No Noncompliance Noted.Major Areas Inspected: Followup of Emergency Preparedness Items from Prior Appraisal on 810511-20 IR 05000286/19820091982-07-0101 July 1982 IE Insp Rept 50-286/82-09 on 820601-04.Noncompliance Noted: Failure to Install Sprinkler Head Specified Per Natl Fire Protection Assoc Code 15,1977 IR 05000003/19820011982-06-29029 June 1982 Revised IE Insp Repts 50-003/82-01 & 50-247/82-02 on 820208- 11.No Noncompliance Noted.Major Areas Inspected:Followup of Emergency Preparedness Items from 810511-20 Appraisal.Rept Includes Revised Page 22 IR 05000286/19820081982-06-28028 June 1982 IE Insp Rept 50-286/82-08 on 820516-0615.Noncompliance Noted:On 820527,solid Radwaste Operations Using Baling Machine Conducted W/O Following Written Procedure & Shroud Door Not Closed as Required During Operation IR 05000247/19820101982-06-24024 June 1982 IE Insp Rept 50-247/82-10 on 820524-28.Noncompliance Noted: Failure to Follow Field Const Procedures & Inadequate Design Interface Control ML20054L0501982-06-15015 June 1982 IE Insp Rept 50-247/82-09 on 820501-31.Noncompliance Noted:Failure to Revise Procedures to Include Mod to Operational Protection Sys Setpoints Completed in Mar 1981 IR 05000247/19820081982-05-20020 May 1982 IE Insp Rept 50-247/82-08 on 820503-07.No Noncompliance Noted.Major Areas Inspected:Fire Protection/Prevention Program,Completion of Fire Hazards Analysis Commitments & SER Commitments ML20062D8201978-10-19019 October 1978 IE Inspec Rept 50-247/78-30 on 780913-14 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Licensee Response to IE Circular 78-08 Environ Qual of Safety Related Elec Equip IR 05000247/19780281978-09-14014 September 1978 IE Inspec Rept 50-247/78-28 on 780825 During Which No Items of Noncompliance Were Noted.Major Areas Inspec Incl: Previously Identified Unresolved Items W/Respect to Records 1989-08-24 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000003/19980191999-03-0909 March 1999
[Table view]Insp Rept 50-003/98-19 on 981130-990222.No Violation Noted. Major Areas Inspected:Review of Facility Mgt & Control ML20237D1381998-08-19019 August 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Between 971024 & 980528,licensee Failed to Assure That Design Change in Oct 1997 Subject to Design Control Measures ML20236M6011998-07-0606 July 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violation Noted:On 970808,double Verifications of Steps 3.4.1 & 3.5.2 of PT-W1,which Involved Checks of DG Compressor,Not Performed,But Records Created ML20154Q1951998-01-22022 January 1998 Partially Deleted Investigation Rept 1-97-038.Noncompliance Noted.Major Areas Investigated:Falsification of Surveillance Test Records by Nuclear Production Technician ML20217H3531997-10-0707 October 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violation Noted:Con Edison Did Not Operate within Restrictions of TS Figure 3.1.A-3,in That Pressurizer Level Was Greater than 30% PNO-I-97-053, on 970826,special Security Insp Will Be Performed,That Will Examine Security Activities at Vermont Yankee,Pilgrim & Indian Point 3.Team Will Include Security Specialists from Region I & NRR1997-08-22022 August 1997 PNO-I-97-053:on 970826,special Security Insp Will Be Performed,That Will Examine Security Activities at Vermont Yankee,Pilgrim & Indian Point 3.Team Will Include Security Specialists from Region I & NRR ML20217R3361997-08-19019 August 1997 NOV & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Measures Were Not Established to Assure That Applicable Regulatory Requirements & Design Basis,Were Correctly Translated Into EOPs IR 05000247/19930261993-11-23023 November 1993 Insp Rept 50-247/93-26 on 931108-12.No Violations Noted. Major Areas Inspected:Mgt Support Plans,Protected & Vital Area Physical Barriers,Detection & Assessment Aids,Protected & Vital Area Access Control of Personnel IR 05000286/19930161993-10-19019 October 1993 Insp Rept 50-286/93-16 on 930802-06 & 0920-24.No Violations Noted.Major Areas Inspected:Isi Program,Procedures,Scope of ISI Work for Outage,Current Insp Plan & Testing Procedures IR 05000286/19930211993-09-17017 September 1993 Insp Rept 50-286/93-21 on 930830-0902.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected & Vital Area Physical Barriers,Detection & Assessment Aids & Protected Vital Area Access Control of Personnel PNO-I-90-094, on 901016,transfer of Fuel Assemblies Stuck in Upper Core Internals.No Apparent Damage to Dropped Fuel Assembly Occurred.Recovery Operations Secured1990-10-17017 October 1990 PNO-I-90-094:on 901016,transfer of Fuel Assemblies Stuck in Upper Core Internals.No Apparent Damage to Dropped Fuel Assembly Occurred.Recovery Operations Secured PNO-I-90-077, on 900906,unplanned Shutdown Greater than 48 H Occurred Due to RCS Packing Leak from Pressurizer Spray Valve.Plant Placed in Hot & Cold Shutdown.Licensee Activities Monitored & State of Ny Informed1990-09-0707 September 1990 PNO-I-90-077:on 900906,unplanned Shutdown Greater than 48 H Occurred Due to RCS Packing Leak from Pressurizer Spray Valve.Plant Placed in Hot & Cold Shutdown.Licensee Activities Monitored & State of Ny Informed PNO-I-90-065, on 900814,licensee Reported That Licensed Reactor Operator Tested Positive for Marijuana as Result of Random Fitness for Duty Test.Operator Unescorted Site Access Suspended for 14 Days1990-08-15015 August 1990 PNO-I-90-065:on 900814,licensee Reported That Licensed Reactor Operator Tested Positive for Marijuana as Result of Random Fitness for Duty Test.Operator Unescorted Site Access Suspended for 14 Days PNO-I-90-063, on 900809,plant Shutdown Due to Potential Loss of Three Emergency Diesel Generators.Caused by Blown Control Power Fuse.Fuse Replaced1990-08-0909 August 1990 PNO-I-90-063:on 900809,plant Shutdown Due to Potential Loss of Three Emergency Diesel Generators.Caused by Blown Control Power Fuse.Fuse Replaced ML20247K5281989-09-14014 September 1989 EN-89-086:on 890919,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 Will Be Issued to Licensee Based on Security Violations Re Access Control & Illumination in Protected Area ML20247B9531989-08-24024 August 1989 Enforcement Conference Rept 50-286/89-15 on 890808.Major Areas Discussed:Security Program During Spring 1989 Plant Outage IR 05000286/19890151989-07-24024 July 1989 Partially Withheld Physical Security Insp Rept 50-286/89-15 on 890605-07 (Ref 10CFR73.21).Violations Noted Re Physical Barriers,Vital Areas & Access Controls.Major Areas Inspected:Detection & Assessment Aids & Alarm Stations ML20245G2181989-06-21021 June 1989 PNS-I-89-010:on 890621,Dept of Investigation in New York City Received Call Threatening Destruction of Plant & Ref 1977 Incident Where Damage Inflicted on Plant.Bomb Threat Contingency Procedures Implemented & Security Maintained IR 05000286/19890031989-06-13013 June 1989 Enforcement Conference Rept 50-286/89-03 on 890428 in King of Prussia,Pa Re Findings of Insp Repts 50-286/89-03 & 50-286/88-22.Violations Noted.Areas Discussed:Security Program During Current Outage ML20247A1051989-05-0909 May 1989 Notice of Violation from Insp on 890228-0417.Violation Noted:Technicians Failed to Secure Pump When Vibration Level Observed on Pump Motor Exceeded Procedural Limit of 3.5 Mils ML20247A0681989-05-0505 May 1989 Notice of Violation from Insp on 890314-25.Violation Noted: Workers Allowed to Enter High Radiation Areas W/O Being Provided or Accompanied by Individual Authorized in Radiation Protection Procedures IR 05000286/19890051989-04-11011 April 1989 Partially Withheld Physical Security Insp Rept 50-286/89-05 on 890227-0303 (Ref 10CFR73.21).Violations & Noncompliances Noted.Major Areas inspected:non-routine Event,Mgt Support, Security Program Plans & Audits & Physical Barriers ML20154Q7231988-09-21021 September 1988 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $75,000.Violations Noted:Qualification of Containment high-range Radiation Monitors Cable Connector Assembly Deficient PNO-I-88-065, on 880617,unit Tripped Due to High Water Level in Steam Generator 22.Caused by Contractor Cleaner Inadvertently Activating Boiler Feed Pump.Licensee Elected to Enter Cold Shutdown to Repair Connoseals1988-06-20020 June 1988 PNO-I-88-065:on 880617,unit Tripped Due to High Water Level in Steam Generator 22.Caused by Contractor Cleaner Inadvertently Activating Boiler Feed Pump.Licensee Elected to Enter Cold Shutdown to Repair Connoseals IR 05000247/19880121988-05-24024 May 1988 Physical Security Insp Rept 50-247/88-12 on 880407.No Noncompliance Noted.Major Areas Inspected:Program for Protection of Safeguards Info,Per 10CFR73.21,including Use of Required Storage Repositories & Handling Procedures IR 05000286/19880061988-05-19019 May 1988 Physical Security Insp Rept 50-286/88-06 on 880412-14.No Noncompliance Noted.Major Areas Inspected:Plan & Implementing Procedures,Organization,Program Audits,Testing & Maint,Physical Barriers & Security Sys Power Supply PNO-I-88-003, on 880101,steam Generator (SG) 23 Boiled Dry During Plant Heatup.Cause Not Stated.On 880104,station Mgt Started Evaluating Safety Significance of Event & Best Method to Refill Generator.Sg 23 Refilled on 8801051988-01-0707 January 1988 PNO-I-88-003:on 880101,steam Generator (SG) 23 Boiled Dry During Plant Heatup.Cause Not Stated.On 880104,station Mgt Started Evaluating Safety Significance of Event & Best Method to Refill Generator.Sg 23 Refilled on 880105 IR 05000286/19870131987-08-21021 August 1987 Safety Sys Outage Mod Insp Rept 50-286/87-13 on 870422-0714. Rept Describes Activities & Findings Associated W/First Portion of Team Insp Re Outage Design Insp IR 05000247/19870141987-06-0808 June 1987 Emergency Preparedness Insp Rept 50-247/87-14 on 870512-14. No Violations Identified.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 870513 IR 05000286/19870111987-05-14014 May 1987 Insp Rept 50-286/87-11 on 870420-24.No Violations Noted. Major Areas Inspected:Radiological Effluents Control Program,Mgt Controls,Air Cleaning Sys,Program Implementation & Previously Identified Items IR 05000286/19870091987-05-11011 May 1987 Insp Rept 50-286/87-09 on 870402-03.No Violations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting, Including Organization & Operating,Shipping & Receiving, Storage & Internal Control & Records & Repts PNO-I-87-039, on 870430,licensee Identified Potential Circuit Failure Preventing Automatic Start of Auxiliary Feedwater Pumps by Loss of Main Feedwater or lo-lo Steam Generator Signals.Circuit Modified for Independent Relays1987-05-0101 May 1987 PNO-I-87-039:on 870430,licensee Identified Potential Circuit Failure Preventing Automatic Start of Auxiliary Feedwater Pumps by Loss of Main Feedwater or lo-lo Steam Generator Signals.Circuit Modified for Independent Relays IR 05000286/19870031987-04-12012 April 1987 Exam Rept 50-286/87-03OL on 870224-26.Exam Results:Seven Senior Operator Candidates Passed All Portions of Exams.One Candidate Failed All Portions PNO-I-87-025, on 870326,licensee Announced Plans to Shut Down Reactor on 870327 Due to Steadily Increasing Leakage on Reactor Coolant Pump Seal.Caused by Degraded Seal.Shutdown Expected to Last 10 Days1987-03-26026 March 1987 PNO-I-87-025:on 870326,licensee Announced Plans to Shut Down Reactor on 870327 Due to Steadily Increasing Leakage on Reactor Coolant Pump Seal.Caused by Degraded Seal.Shutdown Expected to Last 10 Days IR 05000286/19870021987-03-18018 March 1987 Insp Rept 50-286/87-02 on 870127-29.No Violations Noted. Major Areas Inspected:Dosimetry Staffing & Training, Facilities & Equipment Procedures,Dose Assessment QA & Documentation & Recordkeeping IR 05000247/19870041987-03-16016 March 1987 Insp Rept 50-247/87-04 on 870203-0302.No Violations Noted. Major Areas Inspected:Routine Daily Insps,As Well as Unscheduled Backshift Insps of Onsite Activities,Operations, Maint,Surveillance & Review of Periodic & Special Repts ML20207S3401987-03-11011 March 1987 Notice of Violation from Insp on 870127-29 IR 05000247/19870021987-03-10010 March 1987 Insp Rept 50-247/87-02 on 870127-29.Violation Noted:Failure to Include Acceptance Limits for Battery Electrolyte Temp & Failure to Ensure Battery Room Temp within Normal Bounds ML20207R1791987-03-0606 March 1987 PNS-I-87-003:on 870306,security Officer at Offsite Training Ctr in Toddville,Ny Received Bomb Threat by Telephone.Search of Site Produced Negative Results.Local Law Enforcement Agencies Responded.Security Measures Heightened IR 05000286/19870011987-03-0505 March 1987 Insp Rept 50-286/87-01 on 870106-0217.Major Areas Inspected: Plant Operations Including Shift Logs & Records,Reactor Trips/Engineered Safeguards Actuation,Surveillance,Maint & Followup to Generic Ltr 83-28 & TMI Action Items ML20212J3921987-03-0202 March 1987 Notice of Violation from Insp on 870106-0202 IR 05000247/19870011987-02-26026 February 1987 Insp Rept 50-247/87-01 on 870106-0202.Violation Noted:No post-maint (Mod) Test Performed After Changing Location of Emergency Diesel Generator Svc Water Flow Indication & Control Instruments PNO-I-87-010, on 870211,reactor Scrammed from Full Power During Transient Initiated by Loss of Instrument Bus.Safety Injection Signal Received on High Steam Flow Coincident W/Low Steam Line Pressure.Plant Stabilized in Hot Shutdown1987-02-12012 February 1987 PNO-I-87-010:on 870211,reactor Scrammed from Full Power During Transient Initiated by Loss of Instrument Bus.Safety Injection Signal Received on High Steam Flow Coincident W/Low Steam Line Pressure.Plant Stabilized in Hot Shutdown ML20210V6021987-02-10010 February 1987 Notice of Violation from Insp on 861215-19 IR 05000286/19860241987-02-0909 February 1987 Insp Rept 50-286/86-24 on 861215-19.Violation Noted:Raychem Splices Identified W/Less than Required 2-inch Overlap & Bending Radii Less than Allowed IR 05000247/19860331987-01-27027 January 1987 Radiation Protection Insp Rept 50-247/86-33 on 861215-19.No Violations Noted.Major Areas Inspected:Alara,Internal Exposure Control & External Exposure Control ML20213A4821987-01-22022 January 1987 Notice of Violation from Insp on 861116-870105 IR 05000247/19861361987-01-21021 January 1987 Meeting Rept 50-247/86-136 on 861209.Major Items Discussed: Plans for Integrated Assessment of Auxiliary Feedwater Sys. Mods Being Considered Include Providing Direct Indication of Overspeed Trip Mechanism Status in Control Room ML20212K3521987-01-20020 January 1987 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 Based on 860811-0922 Insp.Violation Noted:Reactor Heated Up Above 200 F W/Both Recirculation & Containment Spray Pumps Inoperable IR 05000286/19860231987-01-15015 January 1987 Onsite Regular & Backshift Insp Rept 50-286/86-23 on 861118- 870105.Violation Noted:Failure to Follow Administrative Procedures AP-6 & AP-25-3 Re Work Requests & Matl Substitutions,Respectively 1999-03-09 |
Inspection Report - Indian Point - 1978028 | |
---|---|
Assessments |
Text
- . . -
_
. --...- .. .-.-. .
.7,
~
'.' .
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No. 78-28 i i
Docket No. 50-247
License No. DPR-26 Priority -- Category C Licensee: Consolidated Edison Cemeany cf New York, In Irving Place
Facility Name: Indian Point Station (Unit 2)
Inspection at: Buchanan, New York t
Inspection conducted: August 25, 1978 Inspectors: f'
'
- O G. Napuda~, R actor Inspector 'cate signec -
k(b!% , 0:<
D.~ Secxman, Reactor inspector
?l/ 7?
'date signec cate signed i Approved by: I H.' 5. KistsrMhief, Nuclear Support Section cate'signec No. 2, RO&NS Branch
,
Inscection Samary:
Insnection on August 25.1978 (Recort No. 50-247/78-28)
Areas Inscected: Special, unannounced inspection by regional based inspectors of previously icentified unresolved items with respect to records. The inspection consisted of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> on site by two regional based inspector Resul ts: No items of nonccmpliance were identifie ;
,
7evoroo/7 (D I
l Region I Form 12 i
(Rev. April 77)
.
'
.
.,,
_
-
DETAILS
, Persons Contacted
,
- V. Ammirato, Quality Assurance Engineer
- W. Ferreira, Quality Assurance Engineer-NPG
"T. Law, Plant Manager
- C. Limcges, Reactor Engineer
- Schwartz, ISI and Files Controller
- G. Wasilenko, Manager-Quality Assurance ,
The inspector also interviewed other licensee plant staff during the inspection.
( * denotes those present at the exit intervie '
2. Previous Inscection Findinas ,
(0 pen) Unresolved Item (247/77-35-10): Separate and identify all '
stored charts prior to final storage. The licensee representative stated that all Unit 3 charts had been transferred to the new li-censee (PASNY) and that only the most recent Unit 2 charts are still stored in the Chart Room on an in-transit basis. This item remains unresolved pending RI riview of the purmanent chart hancling/ storage cycle, and possibly the permanent storage facility, during a sub-secuent inspectio (Closed) Unresolved Item (247/78-14-02): Revision of ada.inistrative control procedure SA0-101. Revision 6 of this procedure has been issued and it establishes the governing policies for the control of station precedure (0 pen) Unresolved Iten (247/78-14-03): Affect on the procedure control system by the revision of SAO-101. As stated above (247/78-14-02) the subject procedur: has been revised and it appears that other tier procedures and the system may be affected. This item remains unresolved pending RI review of sub-tier procedures and their implementation for consistency with SAO-lG (Closed) Unresolved Item (247/78-14-04): Determination of accepta-bility of one hcur fire rated file cabinets. It has been determined that one hour fire rated file cabinets are considered acceptable subject to the conditions of NFPA-232-1975 guidelines which include the necessary fire lead surveys. RI has reviewed the licensee's survey (parsgraph 3) and determined that it was performed consistent with the general quidelines of NFPA-232-1975. Based on the results of this inspection, this item is considered close .. _ . . . _ . . . _ _ . . . . . _ .
.
- --.-ww- .- .... .
g4 _ ...~.s . .~. .,4_.-
. 4
, .. .
.
..
3. Fire Load Survey References
--
NFPA Standard No. 232-1975, Protection of Records
--
Quality Assurance and Reliability Survey Report-Protection of Records, Revision 1
--
Procedure SAO-121, Nuclear Pcwer Station Quality Assurance
,
Record Management Program, Revision 0 Survey Review The inspectors performed the following to determine whether the fire load survey was performed consistent with NFPA 232-1975 guidelines:
--
Compared the basic methodology / technique to appiicable requirements of the standard;
--
Assessed the input assumptions / parameters for consistency with the guidance in the standard; and,
--
Reviewed the survey decisions made with respect to applicable portions of ANSI N45. The inspectors also performed the folicwing with respect to the Maintenance office, Health Physics main office, Chemistry and I&C area Turbine Floor Modules and Receipt Inspection area (not
.
physicallyinspected).
--
Spot checked the respective checksheet calculation Verified the applicable cabinets fire rating Estimated the content of ccmbustibles and compared this to the survey detail document Verified as correct the areas designated as fire resistiv Spot checked non-fire rated file cabinets for type of docu-mec~t contained therei No items of ncnccmpliance were identifie .
1 . . . . _ . .
, ,,
-
. .
- Control of Combustible Content '
The inspectors noted that no means existed whereby the com-bustible content of a given storage area could be controlled to assure that it remained within the limits corresponding to -
the level of fire protection provided for the records in that ;
area. The licensee stated that tPis matter would be reviewed -
and a method of control would be established by December 1, 1978. This item is unresolved pending review of the licensee's ,
action (50-247/78-28-01) . 2 Unresolved Items
, Items about which more information is required to determine accepta- 1 bility are considered unresolved. Paracraph 3.b of this report contains an unresolved ite ' Exit Interview r
The inspectors met with licensee represent.tives (denoted in Paragraph 1) at the conclusion of the inspection cn August 25, 1978. The inspector summarized the purpose, scope and findings of the inspectio The licensee confirmed the completion date of the unresolved item detailed in Paragraph .
s I
a t
,
-m e m e em m e , e,
._
"m