IR 05000245/1995011

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-245/95-11, 50-336/95-11 & 50-423/95-11.Effectiveness Will Be Examined During Future Insp
ML20128L934
Person / Time
Site: Millstone  Dominion icon.png
Issue date: 10/07/1996
From: Ruland W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Feigenbaum T
NORTHEAST NUCLEAR ENERGY CO.
References
NUDOCS 9610150236
Download: ML20128L934 (2)


Text

- .

.- -. .- - . . -.- - . - . . ~ - . - - - .- . - . - - - . - - . - .

. . l October 7, 1996 s

i Mr. Ted Executive Vice President - Nuclear Northeast Nuclear Energy Company

'

c/o Mr. Terry L. Harpster P. O. Box 128 i Waterford, Connecticut 06385

,

SUBJECT: INSPECTION REPORT NO. 50-245/95-11; 50-336/95-11 AND 50-423/95-11 (REPLY)

Dear Mr. Feigenbaum:

This letter refers to your June 27,1995, correspondence, Reply to a Notice of Violation, in response to our letter, dated May 10,1995, regarding Millstone, Unit 2. This correspondence dealt with your failure to promptly identify and correct a design deficiency affecting the undervoltage modules in the engineered safeguards actuation system. We have reviewed this matter in accordance with NRC Inspection Manual Procedure 92903.

Thank you for informing us of the corrective and preventive actions documented in Attachment 1 of your letter. Their effectiveness will be examined during a future l inspection of your licensed program.

We have also noted that, since the time of this inspection, additional system modifications have been implemented to improve the system performance. One result of the modifications was an improvement in the system immunity to the effects of electrical noise. In addition to the actions already implemented, we understand that you have initiated actions to replace the existing system with more modern equipment to eliminate long term operational and maintenance issues associated with equipment obsolescence.

Your cooperation with us in this matter is appreciated.

Sincerely, William H. Ruland, Chief Electrical Engineering Branch Docket Nos. 50-245, 50-336, 50-423 9610150236 961007 ~~ o PDR [

ADOCK 05000245 G PDR

. _ - -- . .. ...- _- - - -_ . _ - . - _ _ _ - . - - - . . .- _.. _.

! ,

-

.

'

.. l

/

Mr. Ted Distribution: l Region I Docket Room (with concurrences) '

.

C. O'Daniell, DRP NRC Resident Inspector Nuclear Safety Information Center (NSIC)

PUBLIC D. Screnci, PA0 J. Andersen, PM, NRR W. Dean, OED0 P. McKee, Director, NRR M. Davis, NRR D. Mcdonald, PM, NRR V. Rooney, NRR M. Callahan, OCA Inspection Program Branch (IPAS)

DRS File i

l

,

i 1 i DOCUMENT NAME: A:\MS9511. REP

'E" = Copy with attachment / enclosure *N" = No To remive copy a copy of this document, indecate in the box:["C" = Copy without attachment / enclosure fd-111(94 j l0FFICE RI/DRS 4)Y RI/DRS C- l l NAME NDELLA GRECA WBplAND (<l M /f-DATE 07/18/96 JT// /96 07/ /96 07/ /96 07/ /96

[o I 0FFICIAL RECORD COPY