MONTHYEARIR 05000188/20242012024-07-11011 July 2024 Kansas State University - U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000188/2024201 IR 05000188/20232022023-08-0101 August 2023 Kansas State University - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000188/2023202 (Public) IR 05000188/20232012023-06-0505 June 2023 Kansas State University U.S. Nuclear Regulatory Commission Safety Inspection Report 05000188/2023201 IR 05000188/20222012022-07-0606 July 2022 Kansas State University - U.S. Nuclear Regulatory Commission Routine Inspection Report No 05000188-2022201 IR 05000188/20212012021-07-14014 July 2021 Kansas State University, Us Nuclear Regulatory Commission Routine Inspection Report 05000188/2021201 - Cover Letter and Enclosure IR 05000188/20202022020-10-0505 October 2020 Kansas State University - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000188/2020202 - Cover Letter and Enclosure IR 05000188/20192012019-10-30030 October 2019 Kansas State University - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-188/2019-201 and Notice of Violation IR 05000188/20182012019-03-20020 March 2019 Kansas State University U.S. Nuclear Regulatory Commission Routine, Announced Inspection Report No. 50-188/2018201 IR 05000188/20172012017-08-28028 August 2017 Kansas State University - U.S. Nuclear Regulatory Commission Routine, Announced Inspection Report No. 50-188/2017-201 IR 05000188/20172022017-08-28028 August 2017 Kansas State University U.S. Nuclear Regulatory Commission Security-Related Inspection Report No. 50-188/2017-202 (Cover Letter/Public) ML16223A7992016-08-30030 August 2016 Kansas State University - NRC Routine Inspection Report 05000188/2016201, 08/01/16 - 08/04/16 IR 05000188/20132012013-07-24024 July 2013 IR 05000188-13-201; 06/24-27/2013 at Kansas State University Reactor - NRC Routine Inspection Report No. 50-188/2013-201 IR 05000188/20122012012-07-25025 July 2012 IR 05000188-12-201 on June 25-27, 2012 at Kansas State University - NRC Routine, Announced Inspection Report No. 50-188/2012-201 IR 05000188/20112022011-08-23023 August 2011 IR 05000188-11-202 on July 18-21, 2011, at the Kansas State University, Transmittal Letter for NRC Security Inspection Report No. 50-188/2011-202 IR 05000188/20112012011-08-23023 August 2011 IR 05000188-11-201 on July 18-21, 2011 at the Kansas State University, NRC Routine Inspection Report No. 50-188/2011-201 IR 05000188/20102012010-08-0505 August 2010 IR 05000188-10-201, on July 19-22, 2010, Kansas State University IR 05000188/20092012009-07-0909 July 2009 IR 05000188-09-201 on 06/22/09 - 06/25/09 for Kansas State University, Routine, Announced Inspection Report IR 05000188/20082022008-09-0202 September 2008 IR 05000188-08-202, on 08/04-07/2008, for Kansas State University Triga Mark II Research Reactor IR 05000188/20082012008-07-17017 July 2008 IR 05000188-08-201; on 06/12-20/2008; Kansas State University Nuclear Reactor Facility; Examination of Tornado Damage and Repair Activities IR 05000188/20072022007-08-30030 August 2007 IR 05000188-07-202, on 08/21-23/2007, for Kansas State University Triga Mark II IR 05000188/20072012007-03-0909 March 2007 IR 05000188-07-201, on 02/13/2007 - 02/15/2007, Kansas State University Triga Mark II Facility IR 05000188/20062012006-09-19019 September 2006 NRC Routine, Announced Inspection Report No. 50-188/2006-201 IR 05000188/20062032006-08-22022 August 2006 NRC Inspection Report No. 50-188/2006-203 IR 05000188/20042012005-01-0303 January 2005 NRC Routine, Announced Inspection Report No. 05000188-04-201, on 11/16-19/2004, Ksu Nuclear Reactor Facility IR 05000188/19992011999-09-24024 September 1999 Insp Rept 50-188/99-201 on 990830-0902.No Violations Noted. Major Areas Inspected:Review of Selected Aspects of Operations Program,Organizational Structure & Functions Program,Design Control Program & Review & Audit Program IR 05000188/19970011997-05-0202 May 1997 Insp Rept 50-188/97-01 on 970407-11.No Violations Noted. Major Areas Inspected:Operations,Maint & Facility Support IR 05000188/19890011989-03-10010 March 1989 Partially Withheld Insp Rept 50-188/89-01 on 890206-09 (Ref 10CFR2.790(d)).Violation Noted:Failure to Establish Control Over Facility Access Keys.Major Areas Inspected:Mgt Organization,Surveillance Requirements & Physical Security IR 05000188/19890041989-02-22022 February 1989 Notification of Enforcement Conference W/Util on 890224 in Arlington,Tx to Discuss Insp Rept 50-188/89-04 Findings Involving High & Very High Radiation Area Controls & Procedural Compliance IR 05000188/19880011988-06-0303 June 1988 Ack Receipt of Informing NRC of Steps Taken to Correct Violations & Deviations Noted in Insp Rept 50-188/88-01.Addl Clarification Warranted as Discussed During 880526 Telcon Re Listed Deviation IR 05000188/19860021986-12-24024 December 1986 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-188/86-02 IR 05000188/19860011986-05-30030 May 1986 Insp Rept 50-188/86-01 on 860430-0501.No Violation or Deviation Noted.Major Areas Inspected:Class II Research & Test Reactor Operations,Including Operating Logs,Emergency Plans,Operating Procedures,Experiments & Audits 2024-07-11
[Table view] Category:Inspection Report Correspondence
MONTHYEARIR 05000188/20072022007-08-30030 August 2007 IR 05000188-07-202, on 08/21-23/2007, for Kansas State University Triga Mark II IR 05000188/20072012007-03-0909 March 2007 IR 05000188-07-201, on 02/13/2007 - 02/15/2007, Kansas State University Triga Mark II Facility 2007-08-30
[Table view] |
Text
rch 9, 2007
SUBJECT:
NRC ROUTINE, ANNOUNCED INSPECTION REPORT NO. 50-188/2007-201
Dear Mr. Whaley:
This letter refers to the inspection conducted on February 13 to 15, 2007, at your Nuclear Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, the NRC has identified a violation of NRC regulations that was evaluated as having very low safety significance. This violation is being treated as a Non-Cited Violation (NCV), consistent with Section VI.A of the Enforcement Policy. The NCV is described in the subject inspection report. If you contest the violation or significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001 and the NRC Inspector. No response to this letter is required.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions concerning this inspection, please contact Marcus H. Voth at 301-415-1210.
Sincerely,
/RA/
Johnny Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-188 License No. R-88 Enclosure: NRC Inspection Report No. 50-188/2007-201 cc w/enclosure: See next page
Kansas State University Docket No. 50-188 cc:
Office of the Governor State of Kansas Topeka, KS 66612 Mayor of Manhattan P.O. Box 748 Manhattan, KS 66502 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
Mr. Paul