IR 05000188/2008202

From kanterella
Jump to navigation Jump to search
IR 05000188-08-202, on 08/04-07/2008, for Kansas State University Triga Mark II Research Reactor
ML082390745
Person / Time
Site: Kansas State University
Issue date: 09/02/2008
From: Johnny Eads
Research and Test Reactors Branch B
To: Whaley P
Kansas State University
Voth M, NRR/ADRA/DPR/PRT, 415-1210
References
IR-08-202
Download: ML082390745 (13)


Text

September 2, 2008

SUBJECT:

NRC INSPECTION REPORT NO. 50-188/2008-202

Dear Mr. Whaley:

During the period August 4 to 7, 2008, the U.S. Nuclear Regulatory Commission (NRC)

conducted a routine inspection at your Kansas State University TRIGA Mark II Research Reactor Facility. The enclosed report presents the results of that inspection.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance of Nuclear Regulatory Commission requirements was identified. No response to this letter is required.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC=s Agencywide Document Access Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Marcus Voth at 301-415-1210.

Sincerely,

/RA/

Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

Docket No. 50-188 License No. R-88

Enclosure: As stated cc w/ enclosure:

See next page

Kansas State University Docket No. 50-188

cc:

Office of the Governor State of Kansas Topeka, KS 66612

Thomas A. Conley, RRPJ, CHP, Section Chief Radiation and Asbestos Control KS Dept of Health & Environment 1000 SW Jackson, Suite 320 Topeka, KS 66612-1366

Mayor of Manhattan P.O. Box 748 Manhattan, KS 66502

Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

September 2, 2008 Mr. Pau