IR 05000188/2008201
| ML081960319 | |
| Person / Time | |
|---|---|
| Site: | Kansas State University |
| Issue date: | 07/17/2008 |
| From: | Johnny Eads NRC/NRR/ADRA/DPR/PRTB |
| To: | Whaley P Kansas State University |
| Schoenebeck G, NRR/DPR/PRTB 415-6345 | |
| References | |
| IR-08-201 | |
| Download: ML081960319 (25) | |
Text
July 17, 2008
SUBJECT:
KANSAS STATE UNIVERSITY - NRC NON-ROUTINE INSPECTION REPORT NO. 50-188/2008-201
Dear Mr. Whaley:
This letter refers to the inspection conducted June 12 through June 20, 2008, at the Kansas State University Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of this inspection.
The inspection examined tornado damage to the facility and repair activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions concerning this inspection, please contact Greg Schoenebeck at 301-415-6345.
Sincerely,
/RA/
Johnny Eads, Branch Chief
Research and Test Reactors Branch B
Division of Policy and Rulemaking
Office of Nuclear Reactor Regulation
Docket No. 50-188 License No. R-88
Enclosure: NRC Inspection Report No. 50-188/2008-201
cc w/enclosure: See next page
Kansas State University Docket No. 50-188
cc:
Office of the Governor State of Kansas Topeka, KS 66612
Thomas A. Conley, RRPJ, CHP, Section Chief Radiation and Asbestos Control KS Dept of Health & Environment 1000 SW Jackson, Suite 320 Topeka, KS 66612-1366
Mayor of Manhattan P.O. Box 748 Manhattan, KS 66502
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
July 17, 2008 Mr. Paul