IR 05000155/2003001

From kanterella
Jump to navigation Jump to search
IR 05000155-03-001(DNMS) on 01/06/03 and 02/21/03 for Big Rock Point, Reviewing Licensee'S Performance Related to Spent Fuel Safety and Radiological Safety
ML030780474
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 03/12/2003
From: Chris Miller
NRC/RGN-III/DNMS/DB
To: Haas K
Consumers Energy
References
-RFPFR IR-03-001
Download: ML030780474 (11)


Text

rch 12, 2003

SUBJECT:

BIG ROCK POINT INSPECTION REPORT 05000155/2003-001(DNMS)

Dear Mr. Haas:

On February 21, 2003, the NRC completed an inspection at the Big Rock Point Nuclear Plant.

The purpose of the inspection was to determine whether decommissioning activities were conducted safely and in accordance with NRC requirements. Specifically, the inspectors evaluated spent fuel safety and radiological safety. At the conclusion of on-site inspections on January 9, and February 21, 2003, the inspectors discussed the inspection findings with you and members of your staff.

This inspection consisted of an examination of decommissioning activities at the Big Rock Point Nuclear Plant as they relate to safety and compliance with the Commissions rules and regulations. Areas examined during the inspection are identified in the enclosed report.

Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations of activities in progress, and interviews with personnel.

Based on the results of this inspection, the NRC did not identify any violations. The decommissioning activities reviewed were being conducted in accordance with applicable regulations and license conditions.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

We will gladly discuss any questions you may have regarding this inspection.

Sincerely,

/RA/

Christopher G. Miller Decommissioning Branch Docket No. 05000155 License No. DPR-6 Enclosure: Inspection Report 05000155/2003-001(DNMS)

See Attached Distribution