U. S. NUCLEAR REGUL\\ TORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT 50-18/81-01 (VBWR)

_O.

50-70/81-02 (GETR)

REGION V

/,?M ("

50-73/81-02 (NTR Report No. 50-183/81-01 (EVESR)

.

50-18 50-73 DFR-1(VBWR) R-33(NTR)

Docket No. 50-70 50-183 License No. TR-1(GETR) DR-10 Safeguards Group (EVdR)

Licensce:

General Electric Comoany Vallecitos Nuclear Center Pleasanton. California 94566 Vallecitos Boiling Water Reactor (VBWR) Huclear Test Reactor (NTR)

Facility Nace: General Electric Test Reactor (GETR) ESADA Vallecitos Experimental Superheat Reactor (EVESR)

Inspection at:

Vallecitos Nuclear Center Inspection condu ted:

May 13-15.18, 20 =d June 4,1981 Ins pec tors :

!

R'y. Nort, Radiation Spe list

' Dafe Signed C

W'

l 7. Young, %gtor Insyct '

/ Wate signed kWMa 7h/s/

u

.

g T Wpilet't, actor In p tor

/

I Date Signed

/

Approved ;'y:

/'.

'7

/ g"/

.

F. A. Wenslawski, Chief, Reactor Radiation Protection Sec. D,(te tign'ed

'

L/

7/I!8/

Approved by:

G. (. Zwh3 zig, Ac$ing\\Ehief, Reactor Projects Sec. 2 Da'te Signed Re or Oper ions Projects Branch Approved by:

.

O b

'

H. E. Book, Chief, Radiological Safety Branch ( Date Signed Summary:

Inspection on May 13-15, 18, 20 and June 4, 1981 (Report No. 50-18/81-01, 50-70/81-02, 50-73/81-02 and 50-183/81-01)

Areas Inspected: Routine unannounced inspection by a regional based inspector

,

of the organization, procedures, training, respiratory protection program,

!

i personnel monitoring, surveys, posting and labeling, technical specification requirements, radioactive effluents, emergency planning, GETR Seismic Trip l

checkout, and independent measurements.

The inspection involved 32 inspector hours on-site by three regional based inspectors.

Results: Of the areas inspected, three items of noncompliance were identified bursuantto,10CFR20.103(b)(1);10CFR20.103(a)(3)andGETRTechnical pecification 9.1 as described in paragraph 11.

,.... _

'

b RV Form 219 (2)

'

0107270232 010708 DR ADOCK 05000 l

...

.

DETAILS 1.

Persons Contacted

  • R. Butler, Manager, Radioactive Products and Services, Irradiation Processing Operation (IPO)

G. Cunningham, Senior Licensing Engineer, Nuclear Safety and Quality Assurance (NS&QA)

  • W. King, Manager, Nuclear Safety Technology (NST), NS&QA E. Strain, Nuclear Safety Engineer, NST P. Webb, Manager, Radiological and Environmer.tal Protection, (R&EP),

NS&QA

  • C. Hooker, Supervisor, Radiation and Environmental Protection, R&EP R. Gest, Environmental Protection Specialist, R&EP R. Berryman, Radiation Dosimetrist-Specialist, R&EP C. Leighty, Manager, NTR Operations, Reactor Irradiations (RI)
  • P. Kachel, Manager, GETR Operations, RI W. Springsteen, Planning Specialist, GETR R. Hallquist, Shift Supervisor, GETR E. Hagberg, Shift Sups. visor, GETR S. Jackson, Reactor Operator, GETR L. Campbell, GETR Monitor, R&EP
  • Denotes attendance at exit interview.

2.

Organi7ation The Vallecitos Nuclear Center (VNC) organization as it relates to the facilities inspected is described in the following chart.

Irradiation Processing Operation (IPO)(VNC Site Management)

'

i

_

i Nuclear Safety & Quality Reactor Irradiations (RI)

Assurance (NS&0A)

GETR Operations Nuclear Safety Technology (NST)

NTR Operations Licensing Nuclear Safety Engineer (2)

Radiologica'i Engineer Criticality Enaineer Radiological &

Environmental Protection (R&EP)

Environmental Protection Specialist Radiation 00simetrist-Specialist Supervisor, Radiation & Environmental Protection I

lR&EPMonitors(6)

- - _ _ _ _ _ _ - _ _ - _ _ _ _ _ _ _ _ _ _

_ _ _

.

'

Four of the six R&EP monitors are assigned to provide shift coverage at GETR.

During weekends and backshifts the GETR monitors provide radiation protection coverage of the VNC site. The weekday GETR monitor

is also responsible for monitoring activities at facilities rnd buildings 103 (Metallurgy and Chemistry), 104 (Facilities Maiatenance)

106 (Engineering and Shop Operations), 300 (VBWR and EVESR), 400 (Administration, Personnel and Marketing), hillside storage area, waste evaporator and the site I

basins.

The two other monitors are assigned to the RML (Radioactive Materials Laboratcry) and to the NTR and decomissioning the AFL (Advanced Fuel Laboratory) respectively.

No items of noncompliance were identified.

3.

Procedures The licensee has established, implements and maintains Nuclear Safety Procedures under NS&QA and VNC Safety Standards. A VNC Safety Standard addressing ALARA contains a corporate comitment to maintaining exposures

ALARA. The procedures detail the radiation protection program in the areas of dosimetry, radiation surveys, instrumentation, audits, reviews of experiments and procedure changes, training in radiation protection and emergencies and miscellaneous topics including reporting of unusual

.

occurences and incident incestigation, recomendations and followup.

VNC Safety Standards address specific topics such as dosimetry which includes assignment of administrative responsibility, issuance and control of personnel dosimetry devices, badge change frequency and

,

external exposure limits. Nuclear Safety Manual, Volume 1, Respiratory Protection, describes the. program including user qualification, equipment description, selection, use, care and maintenance.

No items of noncompliance were identified.

4.

Training The licensee provides a series of radiation safety training courses including New Employee Orientation (NE0), Initial Radiation Safety Orientation (IRS 0), Radiation Protection Fundamentals (RPF) and Radiation Safety at VNC (RSVNC). Training requirements and retraining frequency are based on work activities and access to controlled access areas.

Respiratory protection training includes classroom training, a written examination, requires a medical examination, fitting and challenge atmosphere testing. A computcrized system is used to maintain records

m

.

..

-3-of training in addit.s. to archival copies of examinations and scores.

No items of noncomplianC were identified.

5.

Personnel Moni', J VNC Safety Standards 5.2.1 External Dosimetry, 5.2.2 Special Planned Exposure, 5.3.0 Bioassay Program _ and 5.3.1 Internal Dosimetry and Dosinh Classification, describe the program.

Monthly, quarterly and biweekly film badges are provided by Radiation Detection Company.

Occasionally film badges are exposed to a calibration source, using an R-meter to verify exposure, as a quality control check on the badge supplier.

In addition in 1979 the licensee participated in the University of Michigan study submitting badges including NTA film and albedo dosimeters for exposure and later processing by the supplier.

Records of pocket ionization chamber exposures are the responsibility of the individual user.

The total exposure for the VNC was 67 man rem to employees and 6 man rem to visitors during 1979 and 84 man rem to employees and 8 man rem to visitors during 1980.

In March 1981 a total of 330 GE/VNC employees and 77 nonemployee/ visitors were badged.

Individual exposure records were examined and the highest individual exposures in each period are summarized below:

Group /

No. in group st nd Highegosuremrg st Activity March 1981 1 Q80 2 Q80 3 Q80 4 Q80 Annual 1 Q81 1980 NS&QA 21 (includes 275 565 275 280 1190 375 monitors)

GETR

590 2240 400 690 3030 465 NTR

460 197 446 547 1607 630 The NTR exposure records include cumulative gamma and neutron' exposures.

Albedo dosimeters are used at NTR for neutron energies $ 1 mey and NTA film at the remainder of the site for energies >l mev. VNC Safety Standard 5.2.1 specifies quarterly processing of film badges at exposures 5125 mrem / quarter and monthly badge changes for exposures >125 mrem /

quarter. Neutron monitoring, NTA film or albedo dosimeter are required if exposures > 10 mrem / month are expected.

TLD finger rings are required if hand exposures are expected to exceed 4.6 rem / quarter or four times the whole body exposure.

The licensse's bioassay program includes whole body counts using an on site, shadow shielded, moving bed, multichannel analyzer-gamra

_

_

-

- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

______-

.

-4-scintillation system; urinalysis for tritium, gross alpha and beta, uranium and enriched uranium and knericium performed by Eberline and Plutonium by Radiation Detection Company. A sample of individual records for NTR and GETR personnel were examined. Whole body counts were performed on a routine basis. The examination confirmed that individual records included the results of external and internal dosimetry and that copies of fonn NRC-4 are maintained.

Copies of exposure records, form NRC-5, are provided to each monitored individual's mancger where it is available for review. The licensee provides reports of personnel monitoring to terminating employees.

.

No items of noncompliance were identified.

6.

Surveys-Posting-Ir*+ruments-Technical Specifications Requirements Routine surveys are specified by NS Procedures 3550 for NTR and 3400 for GETR. The GETR procedures have been modified to reflect the long term shutdown status of the reactor.

Surveys in general include dose rate and contamination surveys and air sample and CAM results.

Survey records were examined and confirmatory dose rate and smear surveys were performed.

a.

NTR Survey records for the period January 5 through April 15, 1981 were examined. The records noted that the maximum dose rate in the control room with the reactor at power was 15-20 mr/hr ir an inaccessible area at the reactor room shield door seal.

The inspector measured 12-15 mrad /hr at the same location with the reactr-operating at 100 kw.

Surveys by the inspector noted dose cates of 1-2 mrad /hr at the operators position, 4 mrad /hr in contact with the wall between the south room and the control room with neutron radiography in progress, 9-10 mrad /hr in contact with neutron radiographic sample holder after radiography and removal from the south room, and no detectable radiation in the hallway south of the southroom during a neutron radiographic exposure in the south room.

Surveys were performed using a Health Physics Instruaent, tissue equivalent ion chamber, model 1070, serial number 117, NRC 004760, due for calibration July 15, 1981.

The maximum dose rates reported in the licensee's records were associated with "Nuclepore" irradiations. These dose rates were 1-4 R/hr associated with the "Nuclepore" machine, 20 R/hr in the center above the reactor with the plug removed and 8-12 R/hr at the sides of.the open beam port.

Since the last inspection

"Nuclepore" irradiations were conducted for a pe iod of approximately five months.

_ _ _ _ _ _ _ - _ _ - _ _ _ - _ - _ - _ - _ _ _ - - _ _ - _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

.

.

-5-Smear sample results reported in licensee records were generally less than 100 cpm beta-gamma and 200 dpm alpha per square foot in the control room, south room and hallway outside the facility.

Smear samples collected by the inspector on May 18, 1981 and analyzed at the Region V office included:

Location Beta / gamna Alpha

2 dpm/100 cm dpm/100 cm Control Room-floor

NDA*

Neutron radiography sample holder

NDA Entrance to South Room-floor

NDA South Room-floor

NDA South Room-Inside Lead Shield Posted 1414 NDA as Contaminated

  • NDA-No Detectable Activity Analysis was performed using an NMC, Model PC-55 proportional counter.

Records of analysis of continuous air samples showed results that were a small fraction of 10 CFR 20 Appenaix B Table I values for unidentified beta-gamna and alpha activity. Maximum values observed in north and south rooms were 1.9E-12/ACi/cc beta-ganna and 5.7 E-13/ACi/cc alpha.

Daily samples from the reactor room during non operating periods showed maximum values of 4.9E-11ftCi/cc beta-gaana and 7.6E-13jtCt.'cc alpha. Weekly charcoal cartridges showed maximum value of less than 5.6E-13j(ci/cc iodines for the NTR vent stack and control room and 9E-13 cGi/cc for the reactor f

room.

The licensee has evaluated exposures due to thermal and fast neutrons.

Following completion of shielding modifications at the facility a survey was perforned on October 19, 1971.

On May 12, 1981 a preliminary survey was performed to evaluate the impact of proposed modifications of the facility.

In both cases the reactor was operating at 100 Kw.

In the 1971 survey the " pinhole" collimator was in place resulting in a best case, while in the 1981 survey the " pinhole" had been removed, resulting in a worst case situation.

The licensee is contemplating a modification of the " pinhole" and performed the 1981 survey to support the study underway.

Following the 1971 survey additional shielding was added in some locations to reduce the exposure in certain adjoining, normally unoccupied areas as noted in the attached table. Gamma values are in mrem /

hour.

Neutron values are neutron mrem / hour to gamma mrem / hour ratios.

Ranges for various locations are reporte Location 1971 Survey 1981 Survey Y

f t

f t

f mrem /hr n/

n /p mrem /hr n/

n /c

__.

Control Room (1)

Console operator 1.0 to 0.2 0.6 7.5 0.39 0.0096 and normally 5.0 0.05 0.15

0.17 0.046 occupied areas.

Adjacent to walls 7.0 0.023 0.057 5.0 0.36 0.10 (1) and shield 23.0 0.00087 0.039 50.0 0.032 0.008 doo rs.

South Room (2)

1.0 0.08-0.2 0.17-0.6 Exposure Area Hallway south of 1.0 0.2 0.09 1.7 0.76 0.14 (1) Exposure Room Area East of (1)

1.0 0.12 0.26

0.048 0.012 Exposure Room Room East of 12.0 0.43

0.3 0.5 0.13 Reactor (1)(3)

(1) Shutter open (2) Shutter closed (3) Shielding added following 1971 Survey Access to the NTR facility is controlled by lock and key, security alarms and the VNC guard force during non working hours.

The NTR staff controls access during periods when the facility is in operation.

The facility is appropriately posted and access controlled as required by 10 CFR 19.11, Posting of notices to workers,10 CFR 20.203, Caution signs, labels, signals and controls.

Portable instruments available at the facility included two Eberline model E-120 G-M survey meters and one Eberline model PAC-1-SA, alpha survey meter were within the calibration frequency.

Technical Specifications:

!

Section 2.1 A negative pressure indicating device, observable by the reactor operator, indicated a negative pressure in the reactor room with respect to the control room while the reactor was in operation.

Loss of negative air pressure is signaled by an alar "

.

.

-7-Section 2.2 The NTR vent is monitored for halogens, particulates and noble gases. The monitors are set to alarm at a fraction of the annual average release rate assuming full time facility operation.

Releases from the facility are discussed in paragraph 7.

Section 10.3 Direction of air flow into the reactor room is indicated by doorway flags when the reactor room is open. The R&EP group verifies the operation of the negative pressure gauge monthly.

Sections 10.4 The licensee's records of surveillance of radiation

& 10.5 monitoring instruments for the period February 1980 to May 1981 were examined.

No discrepancies were identified.

Section 9 The administrative requirements of 9.1.1 and 9.1.4 relating to facility management and organization were verified.

No items of noncompliance were identified.

b.

GETR Records of surveys for the period January 29 to April 14, 1981 were examined.

Surveys, performed in accordance with procedures include contact and field dose rate measurements and smear samples.

The survey records showed dose rates to 5 mr/hr on the third floor of containment.

Independent measurements in the same area were 0.5 to 2.0 mrad /hr near the step off pad (S0P) and 1.5 to 3.5 mrad /hr on the test instrument platform.

Dose rates to 10.5 mrad /

hr were measured at the EEHS door on the second floor.

Ground floor measurements were 0.5-1.0 mrad /hr at the air lock and SOP.

The licensee's records noted dose rates to 200 mr/hr at the basement sump and 1 r/hr and 10 r/hr at the entrance to the demineralizer room and in contact with the demineralizers respectively.

Independent measurements in the basement were 2.0-2.5 mrad /hr at the foot of the stairs up to 4.0-4.5 mrad /hr at the control rod drive work area S0P. The tank farm fence dose rate reported as 10 mr/hr in a recent survey was found to be 5 mrad /hr by independent measurement using the instrument identified in paragraph 6.a.

Thelicegsee reported contamination levels f from 5000 to 20,000 cpm /ft beta gamma and less than 200 dpm/ft alpha on the third floor north and

<

south zoneg and bridge with all clean areas and S0P's as less than

100 cpm /ft beta-ganma and 200 dpm/ft alpha.

Independent measurement smear samples collected on May 18, 1981, and analyzed with an NMC, PC-55, proportional counter, indicated the following values:

_ _

_

_

_.

__

.

.

-8-

2 Location dpm/100 cm dpm/100 cm Beta-gamma _

alpha *

.

3rd Floor-SOP 357 NDA

!

3rd Floor-Base of Stairs to Instrument Platform 165 NDA 3rd Floor-Top of Missile Shield 107 NDA 2nd I'loor-Floor outside EEHS door 2898

<2 1st I'loor-Air lock floor 115 NDA 1st Ficor-SOP 160 NDA

-

Basement-Ltquid Poison S0P 1025 NDA Basement-Inside Control Rod Drive Work Area-2000

<2 Posted as Contaminated

  • NDA-No detectable activity Access to the facility is controlled by the VNC security staff and the GETR staff. The GETR staff consists of the manager and a planning specialist and shift crew consisting of a shift supervisor, reactor operator and an R&EP technician. The facility is appropriately posted and access controlled as required by 10 CFR 19.11 Posting of notices to workers and 10 CFR 20.203, Caution signs, labels, signals and controls.

Portable instruments available at the facility included Eberline, RM-15 Radiation Monitor with an HP-210 G-M pancake probe, PAC-15A alpha survey meter, PIC-6A ion chamber survey meter and an E-120 G-M survey meter with an HP-210 pancake probe. All the instruments were within the procedure required calibration. frequency.

Technical Specifications Section C(2)

Releases of radioactive material from the facility are discussed in paragraph 7.

Section D(5)

The licensee submitted an annual report for 1980 (f) & (g)

which addressed significant changes in operating procedures, organization and the results of the on and off site monitoring program. The licensee stated that as of the date of the inspection there had been no significant changes in operating procedures or organization since the issuance of the annual report.

Section 9.1 Written procedures for radiological control and for emergencies which could result in significant releases of radioactive material are subject to review by specifically assigned shift supervisors at two year intervals.

-.

.

.

-9 c.

VBWR and EVESR On June 4,1981, by prearrangement with the licensee surveys were conducted in VBWR and EVESR containment structures. The VBWR entry was special and unscheduled, however the EVESR entry was used by the licensee to satisfy the requirement for one of the semiannual surveys. Patrol Log Book 3, which records the weekly patrol inspections of the two facilities was examined for the period January 4 - June 4,1981. Other than notations concerning routine patrols the only other item was related to preparations for entry during the inspection on June 4.

Surveys were performed using an Eberline E-520, G-M survey meter and HP-270 probe serial number 1747, NRC 007907, due for calibration August 12, 1981.

The entries were made in accordance with procedures including an initial entry in.SCBA for air sampling.

Both facilities are dest.ribed in licensee procedures as contaminated, high radiation areas and were observed to be appropriately posted.

l Surveys in VBWR were limited to the operating floor area.

t

Location Dose Rate (3' above floor)

SmearSamp}es (mrem / hour)

dpm/100 cm Beta /Ganina Alpha

'

Center of Building (general area)

0.05 310

<2 Recirculation Pump Pit above 0.7

-

-

opening-(general area)

Spent Fuel Pool-(general area)

0.6

-

-

Sample Station (general area)

0.4 169 NDA*

Scram Air Compressor (general area)

0.3

-

-

Personnel Access shaft to lower levels 0.2

-

-

Control Rod Drive Platform

-

294 NDA*

'

Airlock Floor

-

122 NDA*

The survey in the EVESR containment was performed at ground level and all below ground level elevations.

  • No Detectable Activity

-10-

.

Location Dose Rate 3' above floor SmearSamp1gs (nrem/ hour)

dpm/100 cm Beta / Gamma Alpha 549' elev-Operating Floor Air lock 0.1

NDA*

Above Reactor Vessel 0.1

NDA*

Above Fuel Storage pool 2-3

-

-

Floor near Fuel Storage Pool

-

344 NDA*

534' elev.

Floor drain 20-30 VNC Survey point 0.5 519' elev.

Bundle Instrumentation Area 0.2

-

-

Floor near Instrumentation

-

2490

<2 503' elev.

Control Rod Drive Area 2-3

-

-

VNC Survey Point

-

-

Sat. Steam Line 18-30

-

-

Floor

-

2231

Mezzanine Area 0.1

-

-

487' elev.

General Area

< 0. 2 3443 NDA Control Rod Drive Room ( 0.1

-

-

l Cleanup System-Regen HtEx

< 0.1

-

-

'

Fuel Cask Surface

-

9429 NDA

  • No Detectable Activity No items of noncompliance were identified.

7.

Radioactive Effluents NTR releases consisted of gaseous effluents.

The effluent stream is

!

monitored by particulate and charcoal cartridge iodine samplers. A kanne chamber is used to measure noble gas releases.

The releases from the facility are discharged through a 3000 cfm stack which operates on a year round basis.

The licensee's effluent release records were examined. The releases from NTR during 1980 were as follows.

(IE Inspection Report 50-73/80-01 paragraph 2, reports releases for 1978 and 1979 which are repeated for comparison purposes).

.

..

-11-Activity Released (Units)

1980 1979 1978 Noble gases (Ci)

190.92 290.6 620.8 Iodine (m Ci)

5.348 0.09 10.2 Alpha (pCi) f4C1)

Beta-Gamma (

3.66 NS NS 0.23 NS NS

  • NS-No significant particulate activity was detected.

Using the most conservative assumptions concerning the Maximum Permissable Concentrations from Column I, Table II, Appendix B of 10 CFR 20 and the Airborne Radioactivity Release Rate Limits from Table II of the Technical Specification the 1980 releases were approximately 1% of the noble gas and 3% of the halogen release rate limits.

Discussion with the licensee disclosed that for 1980, releases from GETR totaled 244.819 Ci of noble gas.

Inasmuch as GETR has been shut down for approximately 21s years the reason for the releases was examined.

Noble gas releases from GETR are based on a continuously operating, NaI scintillation detector monitoring system which samples the 18,000 cfm GETR vent. Weekly the monitoring system is purged and a one hour background count rate (average of 10 points on the monitor recorder chart) is established.

During May 1980 the background was 15 cps.

The calibration of the monitoring gyster.1 has established that 1 cps Ci/cc for noble gases or at the above background equals 1.45 x 10 p / day / cps above background.

vent flow rate the equivalent of 1 Ci The release rate from GETR based on this method of measurement ranged from 11.8 to 30.6 Ci/ month during 1980. Since the licensee records counts above background and calculates a release rate on those counts but takes no credit for periods during which the count rate is below background a net positive release rate is statistically inevitable. The indicated release rate is less than 0.1% of the maximum permissible continuous release rate for noble gases specified in section 3.3, Table I, of the Technical Specifications.

No items of noncompliance were identified.

8.

Tritium in Ground Water Near GETR IE Inspection Report No. 50-70/80-01, paragraph 7, discussed the subject topic. At the exit interview reported in paragraph 8 of that report, the inspector requested that he be informed as to the results of the tank and pipe leak testing which was being conducted by the licensee.

A report titled, Tank Farm Leak Test Final Report, dated October 27, 1980 was provided to the Region V office. The report identified three small leaks, a crack in an above ground pipe fitting, a leak in an instrument air line to an underground tank and a leak in a drain line

_.

.

..

-12-from an infrequently used sink. The report concluded that none of the leaks contributed to the low level tritiated ground water in the GETR area.

The above identified IE Inspection Repert included data on the licensee's ground water sampling and analysis as well as the results of NRC confirmatory analyses. Additional sample data for well B-2 was reviewed during this inspection and is reported along with the earlier data for comparison.

Sample Date Tritium Concentration Comments (FCi/mL)_

2/29/80 3.9 + 0.7 E-5 Licensee Data Previously Reported 2/29/80 4.7 ][ 0.06 E-5 NRC Data Previously Reported 6/9/80 4.1 + 0.69 E-5 Licensee Data 6/14/80 3.7 T 0.69 E-5 Licensee Data 8/8/80 3.9 T 0.7 E-5 Licensee Data 4/16/81 3.9][0.7E-5 Licensee Data This matter is considered closed.

No items of noncompliance were identified.

9.

Emergency Planning The licensee required biennial review of the emergency plan has been completed since the last inspection. There were no significant changes to the plan. The licensee reported that there has been considerable fire training at all facilities. Training drills include facility evacuation with the facili+y staff bringing emergency equipment from the facility and

-

response to the facility by the R&EP monitors.

Scheduled, announced criticality drills with unannounced radiation drills were conducted at NTR (Building 105) on September 9, 1980 and at GETR (200 area) on September 16, 1980. Critiques of the drills were conducted the day of the two drills and were documented in memorandums dated September 10, 1980 (NTR) and September 22, 1980 (GETR).

Critique findings are provided to the facility manager who is required to make decisions concerning the items but who is not necessarily required to take the action indicated by the critique finding.

If the indicated required action is significant and is not taken tne matter is referred to the Vallecitos Technological Safety Group for resolution.

None of the critique items identified in the 1980 drills at NTR and GETR were significant.

The licensee has maintained contact with offsite agencies.

The agreement with Valley Memorial Hospital was reconfirred by letter dated December 9, 1980.

The site Industrial Safety and Fire Proteccion specialist maintains continuing contact with the fire protection mutual aid group through monthly meeting with the Twin Valley Fire Chief's organization.

.

-. -., _ _

,_.

.-

-

-

-

.

..

_

.

..

-13-The licensee reported that the Alamedt katy Office of Energency Services is supplied with revisions to the site emergency plan.

The licensee stated that the California State Office of Emergency Services (0ES)

was telephoned to inform them of emergency plan changes.

The licensee reported that they had been informed that the state OES was not involved with test and researa..h reactors at the present time.

No items of noncompliance were identified.

10. GETR Seismic Trip Checkout The replacement triaxial seismic trip installation and checkout procedure was reviewed and the calibration was witnessed by two Region V inspectors.

The installation and protective covering of the sensors appeared adequate and consistent with similar types of installations / instrumentation.

The following areas of concern were expressed to the licensee, a.

Calibration, Procedure - A step should be included in the procedure to calibrate / verify accuracy of the battery check voltmeters on the front panels of the seismic trip power supplies in the control room.

(50-70/81-02-01)

b.

Instrument Accuracy - A basis should be established to justify calibration frequency and obtain data from units using identical equipment to provide history base if possible.

Also the affects of battery voltage versus instrument sensitivity should be resolved.

(50-70/81-02-02)

A licensee representative stated at the exit management meeting that a 30 day checkout period is underway and an evaluation would be made to address the inspector concerns.

11. GETR-Tank 101 Cleaning-March 7, 1981 The licensee investigates incidents and unusual occurances in accordance with VNC Safety Standards. The records of such investigations for the period since the last inspection (February 25 - March 19,1980)

were examined. There were no investigations associated with NTR and one concerning activities at GETR.

On March 1,1981, an Operations Request Form (0RF),~ 0RF No. 228-19 was issued, " Subject Tk 101/115 Clean Out".

The ORF specified that on March 7 the facilities group was to provide two individuals to clean the tanks under GETR Operations supervision. The individuals were to have whole body exposures not exceeding 500 mr and have completed the VNC Respirator Training. The ORF specified the following precautions:

.

.

'

-14

"(1) Insure breathing air system operational.

(2) Use explosive meter to obtain tank readings prior to performing any work in the tank /s.

(3)

Insure positive control of individual who works in the tank.

(4) Radiation exposure control of individuals will be monitored by the individual supervising the job and or monitor.

(5) Rad waste will be placed in 55 gallon 17-H drums-double bagged.

The drum /s will not be sealed or transferred to Hillside Storage if the material is wet.

(6) Personnel working in Tk-115 must have a urine sample taken as soon as possible after completion of work in tank.

(7) Monitor to survey tank /s after clean out is accomplished.

Survey No. C-165 Once tanks have been cleaned out, instcll manhole covers and bolt in place.

Line up Tk-101 for normal operations."

A survey report date January 8,1981 was attached to the ORF. The survey was based on the use of dosimeters and film badges which had been exposed for 65 minutes at three locations in tank 101, location Exposures corrected to I hour to provide dose rates (mr/hr)

Dosimeter Film Badge Under manhole 3 feet above the tank

,e

bottcm West end of tank, 4 inches above the

74 tank bottom East end of tank, 4 inches above the 390 46L tank bottom A survey performed on March 7,1981 at 0830 indicated dose rates of 360 mr/hr three feet above the bottom of the tank or 6 mr/ minute.

The dose rate from the pile of material which was accumulated by sweeping was reported to be 10 r/hr.

Tank 101 is a buried, cylindrical, 25,000 gallon tank used to collect leakage and for primary system fill-flush activities prior to recirculation through the clean up system and transfer to above ground storage.

Tank 101 is considered to be a clean drain tank. The subsequent activities on March 7,1981 were limited to tank 101.

Tank 115 was not cleaned.

Tank 101 had been drained and allowed to dry to prevent the generation cf wet radioactive waste. The ORF was reviewed by the GETR analyst, manager and the Facilities Supervisor.

The ORF was not reviewed by anyone in the NS&QA organization. The licensee stated that procedures do not require review of proposed activities by the NS&QA organization which includes the radiological engineer in Nuclear Safety Technology or radiation protection staff in the R&EP group. The licensee noted that such reviews normally occur as a result of the activities of

-_

..

.. -

-15-several persons who were absent or otherwise occupied when the ORF was generated.

The licensee's failure to evaluate the use of process or other engineering controls, appears to be contrary to the requirements of 10 CFR 20.103(b)(1) Exposure of individuals to concentrations of radioactive materials in air in restricted areas, which requires that,

"The licensee shall, as a precautionary procedure, use process or other engineering controls, to the extent practicable, to limit concentrations of radioactive materials in air to levels below those which delimit an airborne radioactivity area as defined in 20.203(d)(1)(ii)."

(50-70/81-02-03).

On March 7,1981, Radiation Work Permit (RWP) No. 229-1 for, "Tkl01 Cleanout", was issued.

The RWP required continuous monitoring and anti contamination clothing to include, a cap, hood, no personal outer clothing, two pair coveralls with waterproof outer layer, cotton gloves, waterproof gauntlets and canners gloves, two pairs of plastic shoe covers, air line supplied respirators taped to the hood, film badge and 200 and 1000 mr dosimeters. Timekeeping on the job was not required.

The RWP was initiated at 0815 and terminated at 1045.

During the tank cleaning two Facilities employees (individuals A & B) and the R&EP monitor (individual C) entered the tank. Two GETR operators (individuals D & E) were present to direct the task which consisted of dry sweeping the residue in the tank into piles, shoveling the collected material into 5 gallon buckets which were iemoved through the manhole. On the conclusion of the work several individuals exhibited facial and nasal contamination in the range of 500-2000 cpm beta-gamma.

No alpha activity was detectable.

Prior to beginning work in the tank on March 7,1981, air samples to evaluate possible airborne radioactive materials were not collected nor were samples collected during the performance of the work. Air and tank residue samples were collected and analyzed on March 24, 1981 as a part of the licensee's investigation of the occurance.

The air sample indicated the following concentrations at that time:

Activity Concentration (gCi/cc)

_

Co-60 2.0 E-8 Cs-137 4.5 E-10 Gross beta 1.2 E-8 Gross alpha 1.1 E-12 The licensee concluded that the gross beta consisted principally of Co-60 and Cs-137, the sum of the beta fraction emitted by both nuclides being greater than the gross beta activity identified.

The gross alpha activity was identified to be principally Pu-238.

The ratio of the Pu-238 to Co-60 identified in samples from the tank was approximately 10% of the ratio of the MPC Pu-238 to MPC Co-60.

The licensee concluded that Pu-238 would add approximately 10% to the Co-60 dose received.

The licensee's failure to collect air samples prior to or during the work appears to be contrary to the requirements of 10 CFR 20.103 Exposure of individuals to concentrations of radioactive materials in restricted areas, (a)(3)

..

..

..

-16-which specifies that, "For purposes of determining compliance with the requirements of this section the licensee shall use suitable measurements of concentrations of radioactive materials in air for detecting and evaluating airborne radioactivity in restricted areas...."

(50-70/81-02-04)

The three individuals ("A", "B" and "C") who entered the tank were

!

provided with air line supplied "MSA-Ultravue" respirators.

Individuals

"A", "B" and "C" received training in respiratory protection and were fitted for respirators.

The licensee's investigation and the inspectors examination of training, fitting and testing records confirmed that not all individuals entering the tank wore respirator face pieces for which they had been fitted.

Individual.

Respirator type Type of Use Date Trained Examination fitted (*)

Score

"A" MSA-Clearvue AP, AL 08/15/80 74%

Survive Air SCBA

,

"B" MSA-Ultravue AP, AL 1/9 & 8/15/80 96%

Survive Air SCBA

"C" MSA-Clearvue AP, At 08/15/80 96%

Survive Air SCBA (*) AP - Air Particulate Filter AL - Air Line Supplied SCBA - Self Containea Breathing Apparatus The individuals were issued wallet sized cards identifying the respirator types for which they had been trained and fitted.

The use of unfitted and untested respiratory protective equipment appears to be contrary to the requirements of the GETR Technical Specifications section 9.0 Administrative Requirements, item 9.1, which states in part that,

" Written procedures shall be established and maintained..., for radiological control,..." in that Irradiation Processing Operation, Nuclear Safety _

and Quality Assurance, Nuclear Safety Manual, Volume 1, Respiratory Protection, section 4.3 Respirator User Requirement states, "All individuals using respiratory equipment shall:

...

4.

Have been qualified to use the respiratory equipment specified for the job."

(50-70/81-02-05)

Work in tank 101 was terminated at 1045 on March 7,1981.

Individuals

"A" and "B" received 180 and 200 mr exposures respectively as measured by pocket dosimeter during the tank cleaning. The cumulative first quarter 1981 film measured exposure for the five individuals was:

Individual 1st Quarter 1981 (mrem)_

"A" 110

"B" 100

"C" 375

"D" 340

"E" 120

_

-.

.

_ _ _ _ _ _ _ _

.. -

...

-17-Following identification of facial and nasal contamination the involved individuals were counted, using the licensee's shadow shielded, gamt.a scintillation, multichannel analyzer whole body counting (WBC) system.

The individuals were counted both with the WBC bed both stationary and moving. The licensee interpreted the WBC results in terms of lung and whole body counts with the bed both moving and stationary.

Individual _

Counting Calculated Co-60 Activity (uCi)

Date/ Time Lung Whole Body Stationary Moving Stationary _ Moving

" A" 3/7/81-1110 & 1400 0.005 0.039 0.019 0.042 3/9/81-1645 & 1700 0.010 0.023 0.034 0.024

"B" 3/7/81-1210 & 1300 0.136 0.621 0.459 0.661 3/9/81-1620 0.020 0.043 0.063 0.045

"C" 3/8/81-0230

<1% MPBB and <ICRP Investigation Level

" D" 3/8/81-0120 & 0250 0.025 0.065 0.083 0.069 0.016

-

0.017 3/10/81-0300

-

"E" 3/7/81-not known 0.005

-

0.016

-

0.003

-

0.003 3/9/81-1010

-

The exposures received were less than that which would have been received by an individual exposed for 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> per week for 13 weeks at a uniform concentration of radioactive material in air specified in 10 CFR 20 Appendix B Table I, Column 1,

8 (Co Insol) 9 x 10~9 ACi/mL x 6.3 x 10 ml = 5.67pCi.

(10CFR20.103(a)(1))

Further the licensee implemented the actions required in those cases where the 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> control measure of 10 CFR 20.103(b)(2) is exceeded although the 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> control measure was in fact not exceeded. The licensee's actions included the ir.vestigation and documentation of the occurance and included actier.s to be taken to assure against recurrance.

The licensee calculated the 50 year lung dose to individuals using the standard man value of 0.75 rem /0.14pCi of Co-60 given in ICRP Publication 10.

The licensee used the second WBC data and back calculated the initial quantity deposited to avoid errors possibly introduced by external contamination.

Calculated 50 year Lung Dose Individual Maximum Initial 50 year Lung Activity (pCi) Calculated Dose (rem)

"A" 0.044 0.24

"B" 0.082 0.44

"D" 0.022 0.12

"E" 0.004 0.02

'

-

-

_ _ _ _ - _ _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

.s-

...

-18-i 12., Exit Interview

,

On June 4,1981 the results of the inspection of the NTR, GETR, VBWR and EVESR facilities was conducted with the individuals denoted in paragraph 1.

The licensee was informed that no items of noncompliance

'

were identified in connection with the inspection of the NTR, VBWR and EVESR facilities. The licensee was informed that three items of noncompliance had been identified in connection with the cleaning of Tank 101 at GETR on March 7, 1981.

The items identified in Paragraph 11 included:

10 CFR 20.103, Exposure of individuals to concentrations of radioactive materials in air in restricted areas, (b)(1), (a)(3),

>

and GETR Technical Specification 9.1.

The licensee was informed that

,

while improved pre job planning could have avoided the problems identified in connection with cleaning GETR Tank 101, the post occurance investigation was prompt and thorough.

The inspector expressed concern that the licensee's radiation safety reviews were informal rather than required by procedure.

Further, the concern extended to the level of staffing, which was such that the absence of a few persons could defeat the informal review process.

L