IR 015000012/2019003
| ML19343A766 | |
| Person / Time | |
|---|---|
| Site: | 15000012, 015000012 |
| Issue date: | 11/15/2019 |
| From: | Ryan Craffey NRC/RGN-III |
| To: | Ford G Midland Standard Engineering & Testing |
| References | |
| IR 2019003 | |
| Download: ML19343A766 (2) | |
Text
NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY COMMISSION (07-2012)
10 CFR 2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED:
Midland Standard Engineering and Testing, In Nolen Drive, South Elgin, IL 60177 Location Inspected: Job site in Cedar Lake, IN REPORT NUMBER(S) 2019003 2. NRG/REGIONAL OFFICE Region III U.S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4352 3. DOCKET NUMBER(S)
150-00012 4. LICENSE NUMBER(S)
IL-02264-01 5. DATE(S) OF INSPECTION November 15, 2019 LICENSEE:
The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRG) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:
[l] D D.
Based on the inspection findings, no violations were identifie Previous violation(s) close The violations(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRG Enforcement Policy, to exercise discretion, were satisfie Non-cited violation(s) were discussed involving the following requirement(s):
During this inspection, certain of your activities, as described below and/or attached, were in violation of NRG requirements and are being cited in accordance with NRG Enforcement Policy. This form is a NOTICE OF VIOLATION, which ma"y be subject to posting in accordari"ce with 10 CFR 19.1 (Violations and Corrective Actions)
Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective actions is made in accordance with the requirements of 1 O CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRG will be required, unless specifically requeste TITLE PRINTED NAME SIGNATURE DATE LICENSEE'S REPRESENTATIVE NRG INSPECTOR Ryan Craffey BRANCH CHIEF Robert Ruiz, Acting Chief NRC FORM 591M PART 1 (07-2012)
11/15/2019
NRC FORM 591M PART 3 (07-2012)
U.S. NUCLEAR REGULATORY COMMISSION 10 CFR2.201 Docket File Information SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED:
2. NRG/REGIONAL OFFICE Region III Midland Standard Engineering and Testing, In Nolen Drive, South Elgin, IL 60177 Location Inspected: Job site in Cedar Lake, IN U.S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4352 REPORT NUMBER(S} 2019003 3. DOCKET NUMBER(S)
150-00012 6. INSPECTION PROCEDURES USED 87124 4. LICENSE NUMBER(S)
IL-02264-01 7. INSPECTION FOCUS AREAS All SUPPLEMENTAL INSPECTION INFORMATION 1. PROGRAM CODE(S)
03121 2. PRIORITY
D Main Office Inspection
[] Field Office Inspection 3. LICENSEE CONTACT Gregory Ford - RSO Next Inspection Date:
[Z] Temporary Job Site Inspection US 41 at 14 I st A venue, Cedar Lake, IN PROGRAM SCOPE TBD 5. DATE(S) OF INSPECTION November 15, 2019 4. TELEPHONE NUMBER (84 7) 844-1895 This was an unannounced field inspection of a geotechnical engineering company, authorized by the State of Illinois to use portable gauges for measuring the physical properties of materials. The company conducted these activities in NRC jurisdiction under a reciprocity request filed and approved in September 2019 for the remainder of the calendar yea The scope of this inspection was limited to an evaluation oflicensed activities (compaction testing for new roadways) at a residential construction project in Cedar Lake, Indian '
PERFORMANCE OBSERVATIONS The inspector located one of the licensee's authorized gauge users at the job site in Cedar Lake. The user had a Troxler 3411-B gauge in his possession, but was not planning to perform any compaction testing that day since much of the compacted soil was still frozen. Instead, the authorized user demonstrated the implementation of licensee procedures for the safe use and transport oflicensed material. The user maintained adequate control and constant surveillance of the gauge at all times during the inspection, or else secured it in his vehicle using a combination of locks, chains and a locking truck bed cover to provide at least two independent physical controls against unauthorized removal. These locks and chains also provided adequate blocking and bracing for transport on public highways. The inspector performed independent exposure rate measurements in proximity of the gauge, and noted levels consistent with those provided by the manufacturer in the applicable SSDR Safety Evaluation (NC-646-D-830-S).
The inspector interviewed the user to discuss the status of licensed activities under reciprocity as well as various emergency response scenarios. The user was knowledgeable of radiation protection principles, regulatory requirements, and licensee procedures. The inspector reviewed a selection of available records, including shipping papers, utilization logs, leak test results, O&E procedures, a copy of the company's State of Illinois license, and its initial reciprocity report (NRC Form 241) approved September 16, 2019, which accurately reflected the work performed on the job sit No violations ofNRC requirements were identified as a result of this inspection. The inspector conducted an exit meeting with the licensee's RSO via telephone later that da NRG FORM 591M PART 3 (07-2012)