The following information was provided by the licensee via phone and email:
On January 20, 2026, TVA Sequoyah Nuclear Plant completed a Part 21 evaluation concerning two Flowserve Limitorque actuator/motor assemblies. The assembly model numbers are 'SMB-2' and 'SB-1'. The evaluation of the 'SMB-2' assembly was for the motor pinion gear found installed backwards. The evaluation of the 'SB-1' assembly was for insufficient grease applied to the limit switch gearbox. The evaluation determined that a defect existed for these basic components. The conditions were corrected prior to installation in the containment spray system.
The NRC Resident has been notified.
A written notification will be provided within 30 days.
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The only plant known to be affected at the time of the report is Sequoyah Unit 1.