ENS 57994
ENS Event | |
|---|---|
11:10 Oct 21, 2025 | |
| Title | Both Trains of Control Room Emergency Ventilation System Inoperable |
| Event Description | The following is a summary of information provided by the licensee via phone and email:
On October 21, 2025, at 0610 CDT, while reloading fuel to the reactor vessel, an electrical perturbation initiated a control room ventilation isolation signal (CRVIS). The control room air conditioning system (CRACS) 'A' train A/C unit did not start upon the CRVIS due to a blown fuse. The 'B' CRACS A/C unit was out of service for planned maintenance at the time. At 1020 CDT, the 'A' train CRACS A/C unit was returned to service. Both trains of the control room emergency ventilation system (CREVS) were inoperable for 10 minutes. Due to both trains of CRACS and CREVS being inoperable, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v). This condition caused entry into technical specification (TS) limiting condition for operation (LCO) 3.7.10 condition `E' and 3.7.11 condition `D'. Upon discovery of the condition, fuel movement and core alterations were suspended in accordance with the TS LCO required actions. There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector was notified. |
| Where | |
|---|---|
| Wolf Creek Kansas (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+3.45 h0.144 days <br />0.0205 weeks <br />0.00473 months <br />) | |
| Opened: | Michael J. Payne 14:37 Oct 21, 2025 |
| NRC Officer: | Josue Ramirez |
| Last Updated: | Oct 21, 2025 |
| 57994 - NRC Website
Loading map... | |