ENS 56264
ENS Event | |
|---|---|
19:02 Dec 8, 2022 | |
| Title | Unusual Event Due to Excessive Reactor Coolant System Leakage |
| Event Description | At 1402 EST Turkey Point Unit 3, while operating at 100 percent, declared an Unusual Event due to unidentified leakage greater than 10 gallons per minute for more than 15 minutes. The abnormal procedure for Reactor Coolant System leakage was entered. The plant remains at 100 percent power. The cause of the leakage is under investigation.
At 1446 EST it was verified that the leak had been isolated. The plant remains at 100 percent power. Unit 4 was unaffected. State and local authorities were notified by the licensee. The NRC Resident Inspector has been notified. Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).
Turkey Point Unit 3 has isolated the leak. The Unusual Event was terminated at 1558 EST. The NRC Resident Inspector has been notified. Notified R2DO (Miller), NRR EO (Miller), and IR MOC (Crouch). Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).
Turkey Point Nuclear Unit 3 is retracting this notification based on the following additional information not available at the time of the notification, Following the event for unidentified RCS leakage on 12/8/22 at 1403 EST, additional information demonstrated that an RCS leak did not exist. A review of indications showed that the in-service seal water return filter D/P [Differential Pressure] rose from 1 psid to 6 psid with a corresponding rise in VCT [Volume Control Tank] level as would be seen with an increase in excess letdown flowrate. Additionally, the on-contact radiation dose rate from the excess letdown piping in the U3 Pipe and Valve Room was measured by RP [Radiation Personnel] to be significantly higher than normal with no other sources of elevated radiation levels noted. Following the closure of CV-3-387, RCS To Excess Letdown HX [Heat Exchanger] Control Valve, a nominal input/output flow balance was able to be restored. Containment parameters including pressure, temperature, sump level and radiation level did not change during the event. Due to the shared nature of piping between excess letdown and seal water return, a challenge to system integrity would not allow RCP [Reactor Coolant Pump] controlled bleed-off to remain in service with a normal flow balance which it has at all times subsequent to the event. Turkey Point Nuclear reported initially based on the available information at the time and to ensure timeliness with emergency declaration and reporting notification requirements. The NRC Resident Inspector has been notified. Notified R2DO (Miller). |
| Where | |
|---|---|
| Turkey Point Florida (NRC Region 2) | |
| Reporting | |
| Emergency class: | Unusual Event |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration | |
| Time - Person (Reporting Time:+-4.38 h-0.183 days <br />-0.0261 weeks <br />-0.006 months <br />) | |
| Opened: | Szemei Choi 14:39 Dec 8, 2022 |
| NRC Officer: | Thomas Herrity |
| Last Updated: | Jan 9, 2023 |
| 56264 - NRC Website
Loading map... | |
Unit 3 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 577732025-06-21T18:38:00021 June 2025 18:38:00
[Table view]10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event - Unit 4 Containment Isolation Failure Due to Bus Lockout ENS 576032025-03-13T23:02:00013 March 2025 23:02:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event - Loss of Offsite Power ENS 562642022-12-08T19:02:0008 December 2022 19:02:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Due to Excessive Reactor Coolant System Leakage ENS 551532021-03-25T01:29:00025 March 2021 01:29:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notice of Unusual Event Declared Due to Fire Alarm in Containment ENS 529522017-09-08T03:14:0008 September 2017 03:14:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event - Hurricane Warning ENS 526212017-03-18T15:19:00018 March 2017 15:19:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared for Indications of Fire in Safety Related Switchgear ENS 489482013-04-19T21:20:00019 April 2013 21:20:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Due to Loss of Offsite Power Greater than 15 Minutes ENS 477972012-04-02T23:33:0002 April 2012 23:33:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event - Fire from Hydrogen Supply to Volume Control Tank ENS 421042005-11-01T03:27:0001 November 2005 03:27:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Declaration: Loss of Offsite Power Due to Loss of Startup Transformer ENS 420782005-10-26T01:40:00026 October 2005 01:40:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to a Small Fire at the Main Turbine Area ENS 420672005-10-23T02:54:00023 October 2005 02:54:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Hurricane Wilma ENS 420012005-09-19T15:04:00019 September 2005 15:04:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Hurricane Rita ENS 419432005-08-25T03:04:00025 August 2005 03:04:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Hurricane Warning ENS 418002005-06-27T07:16:00027 June 2005 07:16:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Declaration of an Unusual Event Due Transformer Fire >10 Minutes ENS 417432005-06-03T04:33:0003 June 2005 04:33:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Declared Unusual Event Due to Rcs Leakage in Excess of Technical Specification Limit ENS 410682004-09-24T21:00:00024 September 2004 21:00:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Hurricane Warning ENS 410072004-09-02T14:56:0002 September 2004 14:56:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Declared 2025-06-21T18:38:00 | |