| Title | Unanalyzed Condition - Nuclear Material Received in Excess of License Limits |
| Event Description | The following is a synopsis of information provided by the licensee via email:
Uranium Recovery and Recycle Services (URRS) personnel were offloading ash on 11/1/22 that they had received in 2003 from the decommissioned Hematite site at Dock 3. The operators opened the Type A drum and from an inner canister pulled out the bag of Hematite ash. The bag had a tag indicating enrichment levels in excess of their license limits. Upon discovery, the operators contacted criticality safety engineering and the safeguards coordinator. The operators were instructed to replace the bag in the canister and drum and to segregate the drums that contained material potentially greater than license limits in accordance with generally accepted guidance for criticality safety. An extent of condition was performed using materials control and accounting records of the received material. It was discovered that several drums potentially contain material in excess of license enrichment limits. The plant is in a safe condition and the steps taken in response to this event are considered to be conservative. This report is being made per 10 CFR 70 Appendix A (b)(1). This event resulted in the facility being in a state that was not analyzed in their Integrated Safety Analysis Report and resulted in a failure to meet the performance requirements of 10 CFR 70.61, specifically there were no controls in place due to it being an unanalyzed condition. Westinghouse is unable to open, sample, and test the ash to determine enrichment until the proposed process has been analyzed with documented controls in place. This issue has been entered into the licensees corrective action program as IR-2022-9728.
The following is a synopsis of information provided by the licensee via email: On 9/12/2023, while offloading additional barrels of Hematite Ash from the the 2003 shipment, A URRS operator identified that the tag for a drum showed the contents have a higher enrichment than that which is recorded in the Chemical Area Manufacturing and Process System (ChAMPS) and on the original paperwork provided by Hematite Fuel Operations. The unloading activity was stopped, and URRS Management and Nuclear Criticality Safety were notified. The unopened pail was placed back in the drum and the drum was segregated from other items in the area. Environmental Health and Safety requested that the remaining seven drums be opened and the contents tag for each be checked against the information in ChAMPS and the original paperwork from Hematite Fuel Operations. This was done. This report is conservatively being made as an update to Event Notification 56199 under reporting criterion 10 CFR 70 Appendix A (b)(1) as an event that resulted in the facility being in a state that was not analyzed in the Integrated Safety Analysis, and resulted in a failure to meet the performance requirements of 10 CFR70.61 similar to the 9 drums of Hematite Ash that were discovered in November 2022 due to it being an unanalyzed condition. Westinghouse believes it is likely that the enrichment listed on the tag of the drum is inaccurate. The issue has been entered into the corrective action program as IR-2023-8953. Notified R2DO (Endress) and NMSS_EVENTS via email.
The following information was provided by the licensee via email: In response to the discovery of the Hematite Ash material with a U-235 enrichment that was potentially greater than 5 percent U-235, Westinghouse submitted two sequential license amendment requests which were approved by the NRC in May 2023 and October 2023, respectively. The first license amendment permitted possession and storage of the drums containing the ash material in a safe configuration. The second license amendment approved sampling, analysis, and blending, if necessary, of the ash material. After receipt of the second license amendment, Uranium Recovery and Recycle Services personnel sampled the drums of suspect ash material, and laboratory personnel performed the analyses of the samples taken to determine U-235 content. Analytical results were less than 4.265 percent U-235 for all of the samples taken. The results confirmed the ash materials were within the license limit for percent U-235, and as a result, blending with lower enrichment materials to meet the license limit was not necessary. Westinghouse is retracting Event Notification 56199 based on the sample results of the Hematite Ash material being less than 5 percent U-235 and the resultant conclusion that the facility was not in an unanalyzed condition state. 10 CFR 70.61 performance requirements were met for the Hematite Ash material based on the nuclear criticality safety controls that were documented and in place for material less than 5 percent U-235. Notified R2DO (Miller) and NMSS_EVENTS via email. |
| Where | |
|---|---|
| Westinghouse Electric Corporation Columbia, South Carolina (NRC Region 2) | |
| License number: | SNM-1107 |
| Reporting | |
| Part 70 App A (B)(1) | |
| Time - Person (Reporting Time:+19.72 h0.822 days <br />0.117 weeks <br />0.027 months <br />) | |
| Opened: | Patrick Donnelly 11:12 Nov 2, 2022 |
| NRC Officer: | Eric Simpson |
| Last Updated: | Apr 4, 2024 |
| 56199 - NRC Website | |
Westinghouse Electric Corporation with Part 70 App A (B)(1) | |
WEEKMONTHYEARENS 561992022-11-01T15:29:0001 November 2022 15:29:00
[Table view]Part 70 App A (B)(1) Unanalyzed Condition - Nuclear Material Received in Excess of License Limits ENS 543352019-10-16T04:00:00016 October 2019 04:00:00 Part 70 App A (B)(1) an Item Relied on for Safety (Irofs) Determined to Be Inadequate ENS 532662018-03-15T15:30:00015 March 2018 15:30:00 Part 70 App A (B)(1) Unanalyzed Scenario Associated with Uranium Recovery and Recycle System ENS 520902016-07-13T04:00:00013 July 2016 04:00:00 Part 70 App A (B)(1), Part 70 App A (A)(4) Degraded Safety Items Caused by Uranium Buildup ENS 483752012-10-04T14:00:0004 October 2012 14:00:00 Part 70 App A (B)(1) Unanalyzed Accident Scenarios for Certain Consequences of Concern ENS 473302011-10-07T20:15:0007 October 2011 20:15:00 Part 70 App A (B)(1) Dimension of Snm Carrying Pails Different from Value in Safety Analysis ENS 461382010-07-28T18:00:00028 July 2010 18:00:00 Part 70 App A (B)(1) Incorporation of 'Incredible' Criticality Sequences Into Integrated Safety Analysis ENS 456552010-01-25T16:30:00025 January 2010 16:30:00 Part 70 App A (B)(1) Unanalyzed Condition - Overflow of Uranium Bearing Ammoniated Wastewater ENS 414182005-02-17T17:00:00017 February 2005 17:00:00 Response, Part 70 App A (B)(1) 24 Hour 91-01 Response Bulletin and Part 70 App a Unanalyzed Condition 2022-11-01T15:29:00 | |