ENS 55167
ENS Event | |
|---|---|
04:00 Apr 1, 2021 | |
| Title | Part 21 Interim Report - Failure of Ametek 300V, 250A Clamp Diodes |
| Event Description | The following is a synopsis of a Part 21 interim report received by email:
COMPONENT DESCRIPTION - 300V, 250 A clamp diodes with Vishay/International Rectifier part numbers IN3737 and IN3737R and Ametek part numbers 07-600250-00 and 07-600251-00, respectively. Diode failures occurred in 20kVA Inverters, Ametek part number 85-VC0200-41 with serial numbers C84733-0211 and C84733-0511. Two failed diodes returned for evaluation were manufactured in India in 2004. PROBLEM EXPERIENCED - TVA has experienced 5 diode failures since November of 2017. The diode failures experienced at TVA resulted in alarms for abnormal conditions and equipment alarms for fan failure, inverter fuse blown, and inverter failure. The equipment will transfer to bypass when a diode fails. POTENTIAL CAUSE - Diodes installed in the TVA equipment were shorted in most cases and degraded in one instance. Only two of the shorted diodes were sent to AMETEK SCI for evaluation. While the precise cause of this failure is unknown, diode failures are generally attributed to transient voltage spikes and overheating. TVA did indicate there have not been any transient events on the DC bus that could have caused this failure. The inverters at TVA are loaded below 50%. This could contribute to increased heat and stress on the diodes due to increased current draw. However, test data from the original testing of the equipment at no load did not show elevated temperatures on the diodes. EFFECT ON SYSTEM PERFORMANCE - Failures described above could result in loss of output voltage and transfer of the static switch to the bypass source which could result in potential loss of load. EVALUATION OF THE POTENTIAL DEFECT - AMETEK is sending the parts to the original manufacturer for further evaluation with the intent to obtain more insight on the interior condition of the diodes. The targeted completion date for this evaluation of the two diodes returned is June 1, 2021.
What is being classified as a 'minor adjustment' is being made to the notification originally submitted on 4/1/2021. All diodes TVA identified as failed were shorted. None were degraded. Notified R2DO (Miller) and the Part 21/50.55 Reactors E-mail group.
The following excepts provide a synopsis of information provided by AMETEK in the final report. ... The failure was caused by electrical overstress, but the specific root cause is indeterminate. PROBLEM YOU COULD SEE: A diode failure could occur and will result in the equipment transferring to bypass, a loss of output voltage, blown fuses, and unexpected alarms such as fan failure, inverter fuse blown, and inverter failure alarms. There are no conclusive warning signs that a failure is imminent, or detection method for predicting an approaching failure. CAUSE: Diodes that failed in the TVA equipment were shorted according to the summaries provided by TVA. Only two of the shorted diodes were sent to AMETEK SCI for evaluation. The condition of all other diodes is unknown. While the precise cause of this failure is unknown, diode failures are generally attributed to transient voltage spikes and overheating. TVA did indicate there have not been any transient events on the DC bus that could have caused this failure. Additionally, AMETEK sent a representative to the site to review the equipment and operating conditions. The field service technician concluded that there were no abnormalities apparent in the operating conditions or the equipment itself. According to TVA, the inverters at TVA are loaded below 50%. The AMETEK field service representative determined load was at 25% of full load during the site visit in August of 2021. This could contribute to increased heat and stress on the diodes due to increased current draw. However, there was no indication of overheating of the diode at no load or 25% of unit C84733- 0511 (1-II). All diodes were within acceptable temperature conditions on the equipment evaluated. EFFECT ON SYSTEM PERFORMANCE: Failures described above could result in loss of output voltage and transfer of the static switch to the bypass source which could result in potential loss of load. ACTION REQUIRED: AMETEK Solidstate Controls recommends that each facility evaluate the potential risk and performs replacement as determined necessary. Evaluation could include oscilloscope measurements across the diodes and temperature measurements of the diodes and the equipment. Voltage readings from the oscilloscope measurement should not exceed the rating of the diode. Temperatures should be compared to original test data and should not exceed 100ø C. Recent evaluations have been unable to pinpoint a failure mode and there are no conclusive connections to previous failures. Only the failures provided in this report have surfaced for the subject part numbers and the failure rate has been low. AMETEK SOLIDSTATE CONTROLS CORRECTIVE ACTION: AMETEK Solidstate Controls will work with you to arrange replacements and spare parts for your application as needed. Please contact our Client Services group at 1-800-222-9079 or 1- 614-846-7500, extension 1. Notified R2DO (Miller) and the Part 21/50.55 Reactors E-mail group. |
| Where | |
|---|---|
| AMETEK, Paragon Energy Solutions Columbus, Ohio (NRC Region 3) | |
| Organization: | Ametek Solidstate Controls |
| Reporting | |
| 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
| Time - Person (Reporting Time:+13.33 h0.555 days <br />0.0793 weeks <br />0.0183 months <br />) | |
| Opened: | Ethan Salsbury 17:20 Apr 1, 2021 |
| NRC Officer: | Lloyd Desotell |
| Last Updated: | Feb 11, 2022 |
| 55167 - NRC Website
Loading map... | |
AMETEK with 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component, 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
WEEKMONTHYEARENS 574832024-10-29T05:00:00029 October 2024 05:00:00
[Table view]10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 - Interim Report for Regulating Transformer ENS 569582023-12-13T00:00:00013 December 2023 00:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect, 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 - Interim Report for Oil Filled Capacitors ENS 554532021-09-09T04:00:0009 September 2021 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Nonconforming Relay Led to Failures of Battery Chargers ENS 551672021-04-01T04:00:0001 April 2021 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect, 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 Interim Report - Failure of Ametek 300V, 250A Clamp Diodes ENS 545202020-02-11T05:00:00011 February 2020 05:00:00 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 Report - Ametek 85-Rp2675-01 Power Supply Mounting Hardware ENS 538162019-01-07T05:00:0007 January 2019 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect En Revision Imported Date 2/1/2019 ENS 535292018-05-01T04:00:0001 May 2018 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Notification - Potential Defect in Ac Voltage Sense Board ENS 505452014-10-16T04:00:00016 October 2014 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Insufficient Spot Weld on Wire Wound Resistor 2024-10-29T05:00:00 | |