ENS 51611
ENS Event | |
|---|---|
05:00 Oct 6, 2015 | |
| Title | En Revision Imported Date 2/11/2019 |
| Event Description | EN Revision Text: POTENTIAL PART 21 INVOLVING A200 SERIES STARTERS
The following is excerpted from a report submitted by QualTech NP, Nuclear Division, Curtiss-Wright Corporation: Pacific Gas and Electric (PG&E) reported to QTNP [QualTech NP] that they have had eight Cutler Hammer A200 series starter failures since September 15, 2008. The failures would remain in the operated/energized contact state with power removed for some period of time. All starters impacted with this failure were continuously energized. The concern was that if tripped, that the main contacts would not open to protect the motor. Testing was performed by Eaton Industrial Controls Division after receiving defective samples from PG&E. The test report from Eaton was received by QTNP for further review and evaluation. On October 6, 2015 QTNP determined that the Cutler Hammer A200 series starter failures may be reportable and an extent of condition review needed to be done. The root cause was a silicon based mold release that remained on the molded parts and would come between the moving (magnet) & fixed armatures. When heated for an extended period of time, this material would become sticky causing anywhere from a minor delay in opening, up to a frozen closed condition. Cutler Hammer has determined that the silicone mold release was first introduced into the manufacturing facility in May, 2008, due to a shortage of the Zinc Stearate Mold release that was traditionally used. The silicon based mold release was periodically used until October 2012. According to Cutler Hammer, anything made after January 1, 2013 should definitely be silicon mold release free. Thus any starters/contactors of the CH A200 series manufactured between May 2008 & December 31 , 2012 could have this concern. This failure has only been reported for continuously energized applications. The end user should evaluate their applications for this potential failure mechanism. QTNP has notified North Anna, H. B. Robinson, Diablo Canyon, and Hatch.
PDMS material has been identified in the Eaton A200 series starters/contactors with date code T4115 (41st week of 2015) which is outside the range of May 2008 to December 2012 that were originally identified in NRC Event 51611 from 2015. This resulted in a few instances where the starter did not immediately open when the power was removed. Notified R2DO (Masters), R4DO (Werner), and PART 21/50.55 REACTORS via email |
| Where | |
|---|---|
| Qualtech Np Cincinnati, Ohio (NRC Region 3) | |
| Organization: | Qualtech Np |
| Reporting | |
| 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
| Time - Person (Reporting Time:+1761.83 h73.41 days <br />10.487 weeks <br />2.413 months <br />) | |
| Opened: | Margie Hover 15:50 Dec 18, 2015 |
| NRC Officer: | Dong Park |
| Last Updated: | Feb 8, 2019 |
| 51611 - NRC Website | |
Qualtech Np with 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
WEEKMONTHYEARENS 549982020-08-26T04:00:00026 August 2020 04:00:00
[Table view]10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Failure of Air Conditioner Compressor Head Gasket ENS 516112015-10-06T05:00:0006 October 2015 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect En Revision Imported Date 2/11/2019 ENS 510532015-05-07T04:00:0007 May 2015 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Potential Part 21 Involving Struthers Dunn Relays with Contact Resistance Greater than One Ohm ENS 504802014-09-22T05:00:00022 September 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Notification - Discrepancy Between Qualification Report and Installation Instructions ENS 500152014-04-09T05:00:0009 April 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Potential Defect in General Electric Type Cr120Ad Control Relays ENS 499112014-03-12T21:00:00012 March 2014 21:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Allen Bradley Type 700Rtc Relay Spuriously De-Energizing 2020-08-26T04:00:00 | |