ENS 49911
ENS Event | |
---|---|
21:00 Mar 12, 2014 | |
Title | Part 21 - Allen Bradley Type 700Rtc Relay Spuriously De-Energizing |
Event Description | This is a non-emergency notification from Waterford 3 required under 10 CFR PART 21 concerning an apparent deviation from dedicated manufacturing specifications.
On 10/17/2013, it was determined that there have been multiple inadvertent actuations of Engineered Safety Features Actuation Signal (ESFAS) equipment over the previous seven months. These equipment inadvertent actuations are occurring due to Allen Bradley type 700RTC relays spuriously de-energizing. The failure mode causes the relays to intermittently de-energize causing the associated equipment to perform its ESFAS function, not adversely impacting steady state plant operations. The failed relays have been sent to the qualifying vendor and two other failure analysis laboratories for testing. The results were reviewed by Waterford 3 engineers and although the failure mode could not be repeated in the laboratory, the laboratories identified less than adequate solder joints on the relay control circuit and a failed capacitor. The cause of the failed capacitor was identified as less than adequate installation practices during manufacturing. Engineering has determined that effects of these deviations, combined with installation in an application near the qualifying vendor's maximum specified environmental conditions, relevant to elevated voltage and ambient temperatures, has resulted in accelerated aging effects on the sub-components of the relays. The failures have been observed on relays that have been in-service greater than three years. Entergy concluded that for the applications for which the failure mode has been observed, and for other applications where these relays have been installed for more than 3 years, the failures did not result in a substantial safety hazard. However, on 3/12/2014, Entergy completed an evaluation concluding that, had this relay type been installed in other safety related normally energized applications for greater than 3 years, it could have resulted in a substantial safety hazard. Compensatory measures to preclude the malfunction of these relays, until long-term corrective actions are completed, have been implemented. As an interim measure the installed time for these relays is limited to 3 years or less, The Waterford 3 Site VP was informed the same day, 3/12/2014. Waterford 3 has determined that the only other Entergy nuclear facility utilizing these Allen Bradley relay types, possibly in a safety related application, is at James A. Fitzpatrick, to which this condition has been communicated. The licensee has notified the NRC Resident Inspector. |
Where | |
---|---|
Qualtech Np Kilona, Louisiana (NRC Region 4) | |
Organization: | Waterford Steam Electric Station |
Reporting | |
10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
Time - Person (Reporting Time:+17.77 h0.74 days <br />0.106 weeks <br />0.0243 months <br />) | |
Opened: | John Jarrell 14:46 Mar 13, 2014 |
NRC Officer: | Dong Park |
Last Updated: | Mar 13, 2014 |
49911 - NRC Website | |
Qualtech Np with 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
WEEKMONTHYEARENS 549982020-08-26T04:00:00026 August 2020 04:00:00
[Table view]10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Failure of Air Conditioner Compressor Head Gasket ENS 516112015-10-06T05:00:0006 October 2015 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect En Revision Imported Date 2/11/2019 ENS 510532015-05-07T04:00:0007 May 2015 04:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Potential Part 21 Involving Struthers Dunn Relays with Contact Resistance Greater than One Ohm ENS 504802014-09-22T05:00:00022 September 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Notification - Discrepancy Between Qualification Report and Installation Instructions ENS 500152014-04-09T05:00:0009 April 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Potential Defect in General Electric Type Cr120Ad Control Relays ENS 499112014-03-12T21:00:00012 March 2014 21:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Allen Bradley Type 700Rtc Relay Spuriously De-Energizing 2020-08-26T04:00:00 | |