ENS 46870
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
03:17 May 21, 2011 | |
| Title | Hpci Check Valve Leakage Results in System Leakage During Maintenance |
| Event Description | On 5/20/2011 at 2217 [CDT], while performing 1-SR-3.5.1.1(HPCI) MAINTENANCE OF FILLED HPCI DISCHARGE PIPING, operators opened 1-FCV-73-44, HPCI Injection Valve, to fill and vent portions of the system. Once open, the HPCI discharge piping rapidly pressurized to 1000 psig. Operators immediately shut the 1-FCV-73-44 valve. A flood level alarm was received in the control room and water was confirmed to have been leaking from the Gland Seal Condenser. All leakage has stopped.
It is suspected that leakage past 1-CKV-73-45, HPCI TESTABLE CHECK VALVE, caused the rise in discharge piping pressure. An investigation into this event is ongoing. In accordance with TS LCO 3.6.1.3 Condition A, the affected line has been isolated by one closed and deactivated valve. This incident is reportable as an 8-hour ENS notification under 10CFR 50.72 (b)(3)(v) as 'any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: d. Mitigate the consequences of an accident.' It also requires a 60 day written report in accordance with 10CFR 50.73(a)(2)(vii). The NRC Resident Inspector has been notified. The volume of leakage was not specifically known but the leakage resulted in approximately 2 inches of water on the HPCI pump room floor before it was isolated. |
| Where | |
|---|---|
| Browns Ferry Alabama (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+-1.35 h-0.0563 days <br />-0.00804 weeks <br />-0.00185 months <br />) | |
| Opened: | David Hall 01:56 May 21, 2011 |
| NRC Officer: | Bill Huffman |
| Last Updated: | May 21, 2011 |
| 46870 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (22 %) |
| After | Power Operation (22 %) |