| Title | Steam and Feedwater Rupture Control System Unanalyzed Condition at Davis Besse |
| Event Description | System Affected : Steam and Feedwater Rupture Control System (SFRCS)
Actuation / Initiator Affected: Main Steam Line Rupture on Steam Generator Effect of event on plant in current Mode - None Actions Taken or planned: Declared SFRCS Actuation Channels 1 and 2 inoperable. Will track as a Mode 3 restraint against T.S. 3.3.2.2 (SFRCS Instrumentation). Will resolve, correct and retest prior to entry into Mode 3. Discovered SFRCS Logic Channel 1 block upon restoration and repowering after maintenance activities on 10/16/03. After discussions with Engineering Department representatives it has been determined that a design issue exists with the SFRCS system where it would be possible that SFRCS Channels 1 and 2 low pressure trips could be blocked during a scenario where a Main Steam Line Rupture would be followed by a loss of off-site power. This would result in the potential that the OTSG [once through steam generators] with the main steam line rupture would be fed by the AFW system. This requires an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> notification to the NRC per 10CFR50.72(b)(3)(ii)(B). The licensee notified the NRC resident inspector. |
| Where | |
|---|---|
| Davis Besse Ohio (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition | |
| Time - Person (Reporting Time:+-1.1 h-0.0458 days <br />-0.00655 weeks <br />-0.00151 months <br />) | |
| Opened:Some use of "" in your query was not closed by a matching "". | 11:54 Oct 17, 2003 |
| NRC Officer: | Rich Laura |
| Last Updated: | Oct 17, 2003 |
| 40256 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Cold Shutdown (0 %) |
| After | Cold Shutdown (0 %) |
WEEKMONTHYEARENS 573732024-10-10T14:45:00010 October 2024 14:45:00
[Table view]10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition ENS 553212021-06-22T16:08:00022 June 2021 16:08:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition High-Energy Line Break Door Unable to Be Latched ENS 528652017-07-20T16:30:00020 July 2017 16:30:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Potential Tornado Missile Vulnerabilities ENS 520102016-06-16T15:37:00016 June 2016 15:37:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition of Emergency Diesel Generator During Tornado Low Pressure ENS 506392014-11-25T17:00:00025 November 2014 17:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Non-Conservatisms in Methodology Used for Emergency Core Cooling System Performance Requirements ENS 498282014-02-14T08:25:00014 February 2014 08:25:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Shield Building Construction Opening ENS 470962011-07-26T20:00:00026 July 2011 20:00:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Conditions Involving the Safety Related Direct Current (Dc) System ENS 416982005-05-13T20:00:00013 May 2005 20:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition - Electrical Containment Penetration ENS 404572004-01-19T16:20:00019 January 2004 16:20:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Certain Plant Doors May Not Be Able to Withstand Pressure Created by Main Steam Line Break ENS 402562003-10-17T13:00:00017 October 2003 13:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Steam and Feedwater Rupture Control System Unanalyzed Condition at Davis Besse 2024-10-10T14:45:00 | |