LER-2004-002, Technical Specification Violation - Exceeded 20% RTP with LCO Not Met |
| Event date: |
|
|---|
| Report date: |
|
|---|
| 5282004002R00 - NRC Website |
|
text
bAus A subsidiary of Pinnacle If is! Capital Copovration Palo Verde Nuclear Generating Station David M. Smith Plant Manager Nuclear Production Tel.
623-393-6116 Fax.
623-393-6077 e-mail: DSMITHIO@apsc.com Mail Station 7602 P.O. Box 52034 Phoenix, AZ 85072-2034 192-01136-DMS/SAB/DGM/DFH April 2, 2004 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS) Unit 1 Docket No. STN 50-528 License No. NPF-41 Licensee Event Report 2004-002-00 Attached, please find Licensee Event Report (LER) 50-528/2004-002-00 that has been prepared and submitted pursuant to 10CFR50.73. The LER reports a Technical Specification violation where power was raised above 20 percent rated thermal power without meeting the Limiting Condition for Operation (LCO) for Axial Shape Index (ASI).
In accordance with 1 OCFR50.4, a copy of this LER is being forwarded to the NRC Regional Office, NRC Region IV and the Resident Inspector. If you have questions regarding this submittal, please contact Daniel G. Marks, Section Leader, Regulatory Affairs, at (623) 393-6492.
Arizona Public Service Company makes no commitments in this letter. The corrective actions described in this LER are not necessary to maintain compliance with regulations.
Sincerely, DMS/SAB/DGM/DFH/kg Attachment cc:
B. S. Mallett.
N. L. Salgado M. B. Fields NRC Region IV Administrator NRC Senior Resident Inspector for PVNGS NRC NRR Project Manager
APPROVED BY OMB NO. 3150-0104 EXPIRES 7-31-2004
Abstract
On February 8, 2004, during power ascension in Unit 1, power was raised above 20 percent rated thermal power without meeting the Limiting Condition for Operation (LCO) for Axial Shape Index (ASI) which is a violation of Technical Specification (TS) 3.0.4. TS 3.0.4 does not allow entry into the specified condition when LCO 3.2.5 is not met. Control Room Operators had incorrectly interpreted a provisional note in procedures 400P-9ZZ11 Rev. 56, uMode Change Checklist", 40ST-9ZZM1 Rev.26, "Operations Mode 1 Surveillance Log" step 8.1.17, and Surveillance Requirement (SR) 3.2.5.1, and believed they had up to two hours to restore ASI within limits after exceeding 20 percent power.
LER 2001-002-00 reported a similar condition in the past three years when Unit 3 entered Mode 3 with one Auxiliary Feedwater pump inoperable; a condition prohibited by TS 3.0.4.
NRC FORM 366 (7-2001)
(If more space is required, use additional copies of (If more space is required, use additional copies of (If more space Is required, use additional copies of (if more space is required, use additional copies of (If more space Is required, use additional copies of NRC Form 366A) subsequently developed that would significantly affect a reader's understanding or perception of this event, a supplement to this LER will be submitted.
8. PREVIOUS SIMILAR EVENTS
In the past three years, a similar condition prohibited by TS 3.0.4 was reported in LER 2001-002-00 when Unit 3 entered Mode 3 with one Auxiliary Feedwater pump inoperable.
9. ADDITIONAL INFORMATION
None.
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000529/LER-2004-001, Regarding Steam Generator Tube Leak | Regarding Steam Generator Tube Leak | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System | | 05000530/LER-2004-001, Re RCS Pressure Boundary Leakage Caused by Degraded Alloy 600 Component | Re RCS Pressure Boundary Leakage Caused by Degraded Alloy 600 Component | | | 05000528/LER-2004-001, Regarding Reactor Shutdown Due to Reactor Coolant System Pressure Boundary Leakage | Regarding Reactor Shutdown Due to Reactor Coolant System Pressure Boundary Leakage | | | 05000530/LER-2004-002, Regarding an Automatic Reactor Trip on Low DNBR Following a Main Turbine Control System Malfunction | Regarding an Automatic Reactor Trip on Low DNBR Following a Main Turbine Control System Malfunction | | | 05000530/LER-2004-002-01, 1 for Palo Verde, Unit 3 Regarding Main Turbine Control System Malfunction Results in Automatic Reactor Trip on Low DNBR | 1 for Palo Verde, Unit 3 Regarding Main Turbine Control System Malfunction Results in Automatic Reactor Trip on Low DNBR | 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2) | | 05000529/LER-2004-002, On 07/14/2004 Reactor Tripped on Low Departure from Nucleate Boiling Ratio (DNBR) | On 07/14/2004 Reactor Tripped on Low Departure from Nucleate Boiling Ratio (DNBR) | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(vi)(A) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000528/LER-2004-002, Technical Specification Violation - Exceeded 20% RTP with LCO Not Met | Technical Specification Violation - Exceeded 20% RTP with LCO Not Met | | | 05000529/LER-2004-003, Regarding Actuation of Plant Emergency Diesel Generators | Regarding Actuation of Plant Emergency Diesel Generators | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000528/LER-2004-003, Unit I, Regarding Manual Reactor Trip - Slipped Control Element Assembly | Unit I, Regarding Manual Reactor Trip - Slipped Control Element Assembly | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | | 05000528/LER-2004-004, Re Missed Surveillance Requirement for Temperature Detector Calibration | Re Missed Surveillance Requirement for Temperature Detector Calibration | | | 05000528/LER-2004-005, Re Missed Surveillance Tests on Shutdown Cooling Valve RCS Pressure Interlocks | Re Missed Surveillance Tests on Shutdown Cooling Valve RCS Pressure Interlocks | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) | | 05000528/LER-2004-006, Regarding a Loss of Offsite Power (LOOP) and the Subsequent Reactor Trip | Regarding a Loss of Offsite Power (LOOP) and the Subsequent Reactor Trip | | | 05000528/LER-2004-007, Regarding Exceeding the Maximum Power Level Specified in Operating License Condition 2.C(1) | Regarding Exceeding the Maximum Power Level Specified in Operating License Condition 2.C(1) | | | 05000528/LER-2004-008, Regarding Improper Contact Configuration on Containment Isolation Valve | Regarding Improper Contact Configuration on Containment Isolation Valve | | | 05000528/LER-2004-009, Supplemental Report to Licensee Event Report 2004-009-00 | Supplemental Report to Licensee Event Report 2004-009-00 | | | 05000528/LER-2004-011, Re Missed Surveillance Requirements for Containment Lvs Test/Drain Valves | Re Missed Surveillance Requirements for Containment Lvs Test/Drain Valves | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
|