| Q | CCA | Title |
---|
05000482/FIN-2011004-04 | 2011Q3 | | Excessive Oil Contamination for Turbine-Driven Auxiliary Feedwater Pump |
05000482/FIN-2011004-01 | 2011Q3 | | Switchyard Component Failures Cause Loss of Ring Bus and Loss of Offsite Power |
05000482/FIN-2011004-02 | 2011Q3 | H.7 | Technical Support Center External Door Propped Open without Impairment |
05000482/FIN-2011004-03 | 2011Q3 | | Failure to Follow ASME Code Case OMN-1 for Butterfly Valves |
05000482/FIN-2011004-05 | 2011Q3 | H.14 | Failure to Maintain Steam Generator Level Above Lo Lo Level Setpoint |
05000482/FIN-2011007-02 | 2011Q4 | | Inadequate Alternative Shutdown Procedure |
05000482/FIN-2011007-04 | 2011Q4 | H.7 | Procedure Inadequacies Related to Cold Shutdown Repairs |
05000482/FIN-2011007-03 | 2011Q4 | | Failure to Ensure Post-Fire Safe Shutdown Components Remain Free of Fire Damage |
05000482/FIN-2011007-01 | 2011Q4 | | Failure to Verify Isolation of Associated Circuits on Isolation Switches |
05000482/FIN-2011005-04 | 2011Q4 | | Inadequate Evaluation of Effects of Emergency Diesel Generator Frequency Variation on Supplied Equipment |
05000482/FIN-2011005-03 | 2011Q4 | H.4 H.5 | Preconditioning of 480 Vac Breakers Prior to Required Surveillance Testing |
05000482/FIN-2011005-01 | 2011Q4 | P.2 | Failure to Evaluate Gasket Capability |
05000482/FIN-2011005-02 | 2011Q4 | P.2 | Failure to Account for RCP Seal Injection in Safety Analysis for Inadvertent Safety Injection |
05000482/FIN-2011005-05 | 2011Q4 | | Incorrect Retraction of an Event that Could Have Prevented Fulfillment of a Safety Function |
05000482/FIN-2012008-13 | 2012Q1 | | Assess Security Power Supply Anomaly |
05000482/FIN-2012008-01 | 2012Q1 | | Review Main Generator Output Breaker Fault Cause |
05000482/FIN-2012008-02 | 2012Q1 | | Review Startup Transformer Fault Cause |
05000482/FIN-2012008-03 | 2012Q1 | | Review Turbine-Driven Auxiliary Feedwater Pump Mechanical Overspeed Trip Device out of Specification |
05000482/FIN-2012008-04 | 2012Q1 | | Review Operation of the Turbine-Driven Auxiliary Feedwater Pump at Low Flow, Steam Pressures, and Speed |
05000482/FIN-2012008-05 | 2012Q1 | | Assess Impact of Emergency Diesel Generator Ground on Mission Time |
05000482/FIN-2012008-06 | 2012Q1 | | Review Actions to Correct Water Hammer Events in the ESW System |
05000482/FIN-2012008-07 | 2012Q1 | | Review ESW Piping Corrosion Inspections |
05000482/FIN-2012008-08 | 2012Q1 | | Review Source Range Detector Deviation |
05000482/FIN-2012008-09 | 2012Q1 | | Review Failure to Maintain Fire Water Pressure |
05000482/FIN-2012008-10 | 2012Q1 | | Review Inadequate Procedures and Training for Operation of the Temporary Diesel Fire Pump |
05000482/FIN-2012008-12 | 2012Q1 | | Assess Cause of Normal Diesel Fire Pump Failure |
05000482/FIN-2011009-02 | 2012Q1 | H.14 | Inadequate Testing of Emergency Diesel Generator A |
05000482/FIN-2012008-11 | 2012Q1 | | Assess Impact of Failure of Temporary Pump to Match the Functionality of Diesel Fire Pump |
05000482/FIN-2011009-01 | 2012Q1 | H.7 | Inadequate Procedure To Adjust the Compensation In Emergency Diesel Generator Governor |
05000482/FIN-2012002-01 | 2012Q1 | H.7 | Inadequate Procedure Causes Lift of Relief Valve and Reactor Coolant Leak During Shutdown |
05000482/FIN-2012002-02 | 2012Q1 | | Failure to Test ASME O&M Code Category A Valves in Post-LOCA Flow Path |
05000482/FIN-2012002-03 | 2012Q1 | H.7 | Loss of Configuration Control Causes Loss of All Non-Vital Power |
05000482/FIN-2012007-04 | 2012Q2 | H.7 | Untimely Corrective Action |
05000482/FIN-2012007-03 | 2012Q2 | P.3 | Failure to Take Timely Corrective Action to Preclude Repetition |
05000482/FIN-2012007-02 | 2012Q2 | | Failure to Report Conditions That Could Have Prevented Fulfillment of a Safety Function |
05000482/FIN-2012003-01 | 2012Q2 | | Unacceptable Leakage Through Safety Related Watertight Door During Loss of Offsite Power |
05000482/FIN-2012003-02 | 2012Q2 | H.7 | Incorrect Leak Seal Injection Port Installation |
05000482/FIN-2012007-01 | 2012Q2 | P.2 | Inadequate Procedure to Implement Compensatory Measures |
05000482/FIN-2012007-09 | 2012Q2 | H.7 | Inappropriately High Threshold for Condition Report Initiation |
05000482/FIN-2012007-05 | 2012Q2 | H.13 | Failure to Complete Corrective Actions |
05000482/FIN-2012007-06 | 2012Q2 | H.7 | Failure to Implement Procedures to Test SAFETY-RELATED Equipment |
05000482/FIN-2012007-07 | 2012Q2 | P.2 | Failure to Prevent Recurrence of Component Cooling Water System Voiding |
05000482/FIN-2012007-08 | 2012Q2 | P.3 | Failure to Adequately Evaluate the Suitability of NONSAFETY-RELATED Gaskets, O-RINGS, and Seals Installed in SAFETY-RELATED Equipment and to Identify Extent of the Condition |
05000482/FIN-2012201-04 | 2012Q2 | | Security |
05000482/FIN-2012201-03 | 2012Q2 | P.6 | Security |
05000482/FIN-2012201-02 | 2012Q2 | H.14 | Security |
05000482/FIN-2012201-01 | 2012Q2 | H.8 | Security |