Description | Technical Specification 5.4.1.a requires implementation of applicable procedures recommended in Regulatory Guide 1.33, Revision 2, Appendix A, February 1978. Section 7(e) of the Appendix requires procedures for training in radiation protection and personnel monitoring. Section 4.0[1] of Procedure EN-RP-100, Radworker Expectations, Revision 0, requires, in part, that workers notify health physics upon receipt of any electronic alarming dosimeter alarm that was not prebriefed. Contrary to this, on January 17, 2008, a licensee worker failed to notify radiation protection personnel upon receipt of an electronic alarming dosimeter dose rate alarm that was not prebriefed in steam jet air ejector room B. This finding had very low safety significance (Green) because: (1) it was not an ALARA finding, (2) there was no overexposure, (3) there was no substantial potential for an overexposure, and (4) the ability to assess dose was not compromised. This item was entered into the licensees corrective action program as Condition Report CR-RBS-2008-00506 |
Site: | River Bend ![]() |
---|---|
Report | IR 05000458/2009005 Section 4OA7 |
Date counted | Dec 31, 2009 (2009Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | D Stearns G Larkin V Gaddy S Makor C Norton G Vasquez |
INPO aspect | |
' | |
Finding - River Bend - IR 05000458/2009005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (River Bend) @ 2009Q4
Self-Identified List (River Bend)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||