05000458/FIN-2009004-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Ensure Standby Liquid Control System Test Tank Remained Drained |
Description | The inspectors identified a Green noncited violation of Technical Specification 5.4.1.a for the failure of operations personnel to provide adequate procedural guidance to preclude water intrusion into the nonseismically qualified standby liquid control system test tank which resulted in the degradation of both trains of the standby liquid control system. The licensee entered this issue into their corrective action program as Condition Report CR-RBS-2009-3862. The failure to provide appropriate procedures to keep the standby liquid control test tank drained is a performance deficiency. The finding is more than minor because it affects the protection against external events attribute of the mitigating systems cornerstone objective to ensure the availability, reliability, and capability of systems responding to initiating events to prevent undesirable consequences. The inspectors determined that the finding was of very low safety significance because the finding was not a design or qualification deficiency, did not represent a loss of a system/train safety function, and did not screen as potentially risk significant due to external events. This finding has a crosscutting aspect in the area of problem identification and resolutions corrective action program because the licensee failed to take appropriate corrective actions to address safety issues and adverse trends in a timely manner, commensurate with their safety significance and complexity. Specifically, the licensee failed to address the cause of inadvertent water intrusion into the standby liquid control test tank in a timely manner to prevent the common mode failure of both trains of standby liquid control P.1(d) |
Site: | River Bend |
---|---|
Report | IR 05000458/2009004 Section 1R22 |
Date counted | Sep 30, 2009 (2009Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.22 |
Inspectors (proximate) | C Norton L Ricketson G Larkin V Gaddy |
CCA | P.3, Resolution |
INPO aspect | PI.3 |
' | |
Finding - River Bend - IR 05000458/2009004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (River Bend) @ 2009Q3
Self-Identified List (River Bend)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||