| | | Reporting criterion |
|---|
| 05000455/LER-1994-000, :on 940923,rod Drive 2BD Power Cabunet Urgent Failures & Subsequent Reactor Trip Occurred Due to Drop in Rcca.Rack Connector Socket for Group 2 Stationary Regulation Card Repaired |
- on 940923,rod Drive 2BD Power Cabunet Urgent Failures & Subsequent Reactor Trip Occurred Due to Drop in Rcca.Rack Connector Socket for Group 2 Stationary Regulation Card Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000455/LER-1994-001-08, :on 940219,discovered That TS Required Temp Reading for Div 22 Cable Spreading Room Not Being Taken at Correct Location Due to Personnel Error.Personnel Involved Counseled on Attention to Detail |
- on 940219,discovered That TS Required Temp Reading for Div 22 Cable Spreading Room Not Being Taken at Correct Location Due to Personnel Error.Personnel Involved Counseled on Attention to Detail
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1994-001-13, :on 941014,senior Licensed Operator Absent from CR Due to Shift Supervisor Getting Distracted.Identification Badge Being Worn by CR Supervisor to Be Reminded of Role & Responsibilities |
- on 941014,senior Licensed Operator Absent from CR Due to Shift Supervisor Getting Distracted.Identification Badge Being Worn by CR Supervisor to Be Reminded of Role & Responsibilities
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1994-001-05, :on 940201,discovered Several Valves May Not Stroke Under High Differential Pressure Conditions Due to Inadequate Torque Switch Setting.Caution Cards Placed on Effected Valves |
- on 940201,discovered Several Valves May Not Stroke Under High Differential Pressure Conditions Due to Inadequate Torque Switch Setting.Caution Cards Placed on Effected Valves
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000454/LER-1994-002-09, :on 940309,main Steam Safety Valves Setpoints Found Out of Tolerance Due to Calculation Error.Amend to TSs to Allow Tolerance of +3% Requested.Valve Setpoints Will Be Retested by 940509 |
- on 940309,main Steam Safety Valves Setpoints Found Out of Tolerance Due to Calculation Error.Amend to TSs to Allow Tolerance of +3% Requested.Valve Setpoints Will Be Retested by 940509
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000454/LER-1994-003-01, :on 940314,AF Isolation Valve Was Exposed to Potentially Harsh Environ Due to Flood Seal Removal. Verified That AF Tunnel Fso Plates in Place on Both Units & Required That Fso Plates Remained in Place |
- on 940314,AF Isolation Valve Was Exposed to Potentially Harsh Environ Due to Flood Seal Removal. Verified That AF Tunnel Fso Plates in Place on Both Units & Required That Fso Plates Remained in Place
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000454/LER-1994-003-06, :on 940314,AFW Isolation Valve Exposure to Potentially Harsh Environ Occurred Due to Flood Seal Removal.Afw Tunnel Fso Plates Verified in Place |
- on 940314,AFW Isolation Valve Exposure to Potentially Harsh Environ Occurred Due to Flood Seal Removal.Afw Tunnel Fso Plates Verified in Place
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000455/LER-1994-003-10, :on 940924,rod Dropped Into Core Resulting in Reactor Trip & Corresponding AFW Actuation Due to Failure of Main Steam Header Pressure Controller.Controller Replaced.W/ |
- on 940924,rod Dropped Into Core Resulting in Reactor Trip & Corresponding AFW Actuation Due to Failure of Main Steam Header Pressure Controller.Controller Replaced.W/
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000454/LER-1994-004-09, :on 940423,discovered That Oc Waste Gas Decay Had Not Been Sampled After Radioactive Matls Added.Caused by Poor Work Practices & Inadequate Training.Corrective Action:Personnel Retrained |
- on 940423,discovered That Oc Waste Gas Decay Had Not Been Sampled After Radioactive Matls Added.Caused by Poor Work Practices & Inadequate Training.Corrective Action:Personnel Retrained
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000454/LER-1994-005, Informs That for Docket 50-454,LER 94-005 from Byron Generating Station Will Not Be Used | Informs That for Docket 50-454,LER 94-005 from Byron Generating Station Will Not Be Used | |
| 05000454/LER-1994-006-04, :on 940715,fuel Assembly Located in Wrong Region of Spent Fuel Pool Due to Personnel Error.Nuclear Matl Custodian & Individual That Performed Independent Verification Counseled |
- on 940715,fuel Assembly Located in Wrong Region of Spent Fuel Pool Due to Personnel Error.Nuclear Matl Custodian & Individual That Performed Independent Verification Counseled
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) |
| 05000454/LER-1994-007-06, :on 940801,during Rcfr Monthly Surveillance 1B Wide Range Hot Leg RTD Spiked Low.Caused by Splice at RTD Pigtail & Field Cable.Butt Splice Will Be Installed During Next Refueling Outage |
- on 940801,during Rcfr Monthly Surveillance 1B Wide Range Hot Leg RTD Spiked Low.Caused by Splice at RTD Pigtail & Field Cable.Butt Splice Will Be Installed During Next Refueling Outage
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000454/LER-1994-008-06, :on 940803,discovered That Since 940304,CS Valves Not Stroke Time Tested in Closed Direction Due to Misinterpretation of TS Requirements.Ist Review That Added Valves Verified as Complete |
- on 940803,discovered That Since 940304,CS Valves Not Stroke Time Tested in Closed Direction Due to Misinterpretation of TS Requirements.Ist Review That Added Valves Verified as Complete
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000454/LER-1994-009, :on 940908,Unit Unexpectedly Tripped Twice. Cause of First Trip Never Determined.Cause of Second Trip Attributed to Personnel Error.Extensive Trouble Shooting & Implemented Software Change |
- on 940908,Unit Unexpectedly Tripped Twice. Cause of First Trip Never Determined.Cause of Second Trip Attributed to Personnel Error.Extensive Trouble Shooting & Implemented Software Change
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000454/LER-1994-009-07, :on 940908,reactor Trips Occurred During Planned Shutdown Due to Solid State Protection Sys Failure. Caused by Personnel Error.Event Placed in Required Reading for Sys Engineering Dept |
- on 940908,reactor Trips Occurred During Planned Shutdown Due to Solid State Protection Sys Failure. Caused by Personnel Error.Event Placed in Required Reading for Sys Engineering Dept
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000454/LER-1994-010, Informs That LER Number 94-010 from Plant Will Not Be Used | Informs That LER Number 94-010 from Plant Will Not Be Used | |
| 05000454/LER-1994-011, Informs That LER Number 94-011 from Plant Will Not Be Used | Informs That LER Number 94-011 from Plant Will Not Be Used | |
| 05000454/LER-1994-012-05, :on 941006,increased Tube Degradation in Plant, Unit 1 Sg.Caused by Axial Oriented ODSCC Located at Hot Leg Tube Regions Bounded by Tube Support Plates |
- on 941006,increased Tube Degradation in Plant, Unit 1 Sg.Caused by Axial Oriented ODSCC Located at Hot Leg Tube Regions Bounded by Tube Support Plates
| 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000454/LER-1994-013-03, :on 941007,SX Basin Level Switch Breaker Left in Wrong Position After Maint.Caused by Failure of Electrical Maint Dept to Return Equipment to Operating Dept. SX Basin Level Switch Reenergized |
- on 941007,SX Basin Level Switch Breaker Left in Wrong Position After Maint.Caused by Failure of Electrical Maint Dept to Return Equipment to Operating Dept. SX Basin Level Switch Reenergized
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) |
| 05000454/LER-1994-014-04, :on 940915,declared DG Inoperable in Mode 5 Due to Misinterpretation of TS Requirements.Revised Procedures & Electronic Work Control Sys |
- on 940915,declared DG Inoperable in Mode 5 Due to Misinterpretation of TS Requirements.Revised Procedures & Electronic Work Control Sys
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) |
| 05000454/LER-1994-015, :on 941014,senior Licensed Operator Momentarily Left CR Due to Becoming Distracted.Importance of SRO Duties in CR Communicated to Licensed Operating Personnel Via Daily Orders Placed on 941019 & 1210 |
- on 941014,senior Licensed Operator Momentarily Left CR Due to Becoming Distracted.Importance of SRO Duties in CR Communicated to Licensed Operating Personnel Via Daily Orders Placed on 941019 & 1210
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000454/LER-1994-016, Cancelled | Cancelled | |
| 05000454/LER-1994-017, Cancelled | Cancelled | |
| 05000454/LER-1994-018-02, :on 941208,operation of Safety Injection Pump in Mode 4 W/O Two Modes of Isolation from RCS Due to Personnel Error.Counseled Individuals Involved & Enhanced Procedure BOP SI-5 |
- on 941208,operation of Safety Injection Pump in Mode 4 W/O Two Modes of Isolation from RCS Due to Personnel Error.Counseled Individuals Involved & Enhanced Procedure BOP SI-5
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1994-019-02, :on 941215,missed TS Surveillance Due to Operator Not Recording Info.Ro Involved Counselled to Maintain Proper Documentation of Surveillance Requirements |
- on 941215,missed TS Surveillance Due to Operator Not Recording Info.Ro Involved Counselled to Maintain Proper Documentation of Surveillance Requirements
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |