05000440/FIN-2015001-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Liquid Penetrant Testing Procedure Was Not Qualified for Its Full Applicability Range |
Description | The inspectors identified a finding of very low safety significance and associated NCV of Title 10 of the Code of Federal Regulations (CFR) Part 50, Appendix B, Criterion IX, Control of Special Processes, for the licensees failure to properly qualify a non-destructive testing procedure in accordance with applicable codes. Specifically, a liquid penetrant testing procedure was not qualified for its full applicability temperature range in accordance with American Society for Mechanical Engineers (ASME) Code,Section V, Non-Destructive Examination. This finding was entered into the licensees corrective action program as Condition Report 201503175. The failure to qualify a liquid penetrant testing procedure in accordance with ASME Section V was determined to be a more than minor performance deficiency because if left uncorrected, it has the potential to lead to a more significant safety concern. Specifically, since the liquid penetrant testing procedure was not qualified for its full applicability temperature range, liquid penetrant examinations would not be assured to detect flaws in the unqualified temperature range and as a consequence, the potential would exist for a rejectable flaw to go undetected, unknowingly impacting the operability of the inspected system. The inspectors determined the finding was of very low safety significance because it did not result in the loss of operability or functionality for any mitigating systems; thus, the inspectors answered No to the screening questions. The licensee completed a review of liquid penetrant examination records, and did not find an example where the procedure was implemented in the unqualified temperature range. The inspectors did not identify a cross-cutting aspect associated with this finding because it was not confirmed to reflect current performance due to the age of the performance deficiency. Specifically, the inadequate qualifications were performed more than 3 years ago. |
Site: | Perry ![]() |
---|---|
Report | IR 05000440/2015001 Section 1R08 |
Date counted | Mar 31, 2015 (2015Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.08 |
Inspectors (proximate) | J Beavers J Nance M Kunowski M Marshfield T Bilik N Mcmurray |
Violation of: | 10 CFR 50 Appendix B Criterion IX |
INPO aspect | |
' | |
Finding - Perry - IR 05000440/2015001 | ||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Perry) @ 2015Q1
Self-Identified List (Perry)
| ||||||||||||||||||||||||||||||||||||||||||||||