05000395/FIN-2013003-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Modification Leads to Auxiliary Building Flood Vulnerability |
| Description | A URI was identified by the inspectors for an AB flood scenario created during implementation of the ISFSI modification. On April 30, 2013, the licensee initiated condition report (CR) 13-01917 for water exceeding 17 inches in non-safety electrical manhole (EMH) number 8 as identified by their normal inspection process. On May 6, 2013, the licensee initiated CR- 13-01973 for excessive rain that in combination with a trench previously excavated for a modification associated with the new ISFSI project resulted in water intrusion into the AB and a Hi-Hi alarm on the floor drain tank. The resident inspectors expressed a concern regarding these two events and the licensee took immediate actions to back-fill the section of the trench adjacent to EMH-8. The inspectors also expressed a concern regarding the modification review process which failed to identify the creation of a flood vulnerability for site structures housing safety related components. The licensee subsequently initiated CR-13-02022 to evaluate the modification program for any necessary corrections. Pending completion of additional evaluations in determining the performance deficiency (PD) and associated significance, this is identified as URI 05000395/2013003-01, Modification Leads to Auxiliary Building Flood Vulnerability. |
| Site: | Summer |
|---|---|
| Report | IR 05000395/2013003 Section 1R01 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.01 |
| Inspectors (proximate) | E Coffman G Mccoy J Reecea Senguptae Coffman J Reece J Rivera J Rivera Ortiz P Cooper R Hamilton R Kellner |
| INPO aspect | |
| ' | |
Finding - Summer - IR 05000395/2013003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Summer) @ 2013Q2
Self-Identified List (Summer)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||