05000395/FIN-2012005-06
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | RESIN SHIPMENT IN STEEL HIGH INTEGRITY CONTAINER NONCOMPLIANCE WITH 10 CFR 61.52(b)(2) |
| Description | A self-revealing NCV of 10 CFR 61.56(b)(2) was identified because the licensee transported a cask shipment for disposal at the Energy Solutions Disposal Facility, Barnwell, South Carolina, which contained liquid above regulatory limits for final form for burial. The licensee entered the problem into their corrective action program as CR-12-04279. This finding is greater than minor because it was associated with the low level burial attribute of the Public Radiation Safety Cornerstone and adversely affected the cornerstone objective to ensure adequate protection of the public health and safety from exposure to radioactive materials released into the public domain. The finding is of very low safety significance because the shipping cask was discovered to have minimal liquid exceeding the regulatory limit of one half percent of the waste shipment total volume transported to the burial site for disposal and the liquid was discovered prior to waste disposal. The cause of the finding involved the crosscutting area of human performance, the component of resources, and the aspect of complete and accurate procedures, H.2(c), because the procedures did not address the permutation of having wet resin added on top of already dewatered resin, nor did it lead the user to the more restrictive dewatering regimen based on internals as a first choice. |
| Site: | Summer |
|---|---|
| Report | IR 05000395/2012005 Section 2RS8 |
| Date counted | Dec 31, 2012 (2012Q4) |
| Type: | NCV: Green |
| cornerstone | Pr Safety |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71124.08 |
| Inspectors (proximate) | E Coffman E Lea G Mccoy J Laughlin J Reece M Coursey R Hamilton R Williams |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Summer - IR 05000395/2012005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Summer) @ 2012Q4