Finding | |
|---|---|
| Title | Failure to Follow Procedure Results in Reactor Coolant Pump Failure to Transfer and Unit 1 Reactor Trip |
| Description | Green. A self-revealed Green finding was identified for the failure to follow procedure NPG-SPP-22.207, Procedure Use and Adherence Revision 4, which requires that applicable procedures are used for all activities controlled by a written procedure. The licensee entered this into their corrective action program as CR 1291140 The failure to follow procedure NPG-SPP-22.207, Procedure Use and Adherence, Revision 4, was a performance deficiency. The performance deficiency was more than minor because it affected the Initiating Events Cornerstone attribute of Human Performance and adversely affected the cornerstone objective in that it resulted in two reactor trips. The inspectors determined that the finding was of very low safety significance (Green) because it did not cause a reactor trip and the loss of mitigation equipment. The finding was not assigned a cross-cutting aspect since none of the CCAs described in IMC 0310 corresponded to an apparent cause or most significant causal factor of the performance deficiency. (Section 4OA3.6) |
| Site: | Watts Bar |
|---|---|
| Report | IR 05000390/2017002 Section 4OA3 |
| Date counted | Jun 30, 2017 (2017Q2) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | J Nadel J Hamman J Jandovitz G Crespo T Stephen D Simpkins P Cooper C Dykes R Kellner A Nielsen J Panfel |
| INPO aspect | |
| ' | |
Finding - Watts Bar - IR 05000390/2017002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Watts Bar) @ 2017Q2
Self-Identified List (Watts Bar)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||