The inspectors identified a noncited violation of
10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, because the licensee failed to correct a
condition adverse to quality (inadequate instructions that led to low fuel oil and the failure of auxiliary component cooling water pump bearing). Specifically, the licensee\'s corrective action for a previous event called for an operator aid (oil level label). However, the operator aid contained incorrect and confusing information. Consequently, another auxiliary component cooling water pump failed. The licensee entered this deficiency into their corrective action program as Condition Report
CR-WF3-2008-0350. The finding was more than minor because it was similar to nonminor violation example 4.f in
Inspection Manual Chapter 0612, Appendix E, \"Examples of Minor Issues,\" in that the problem affected auxiliary component cooling water Pump B operability. Using the Manual Chapter 0609, \"
Significance Determination Process,\" Phase 1 Screening Worksheet, the issue screened as having very low safety significance because it did not: (1) represent a loss of safety function; (2) represent an actual loss of a single train of equipment for more than its Technical Specification allowed outage time; or (3) screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event. This finding had crosscutting aspects associated with Human Performance area, resources program component, because the licensee failed to have correct labeling on components [H.2.(c)] (Section 4OA2)