05000373/LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-033/03L-0.Detailed Event Analysis Encl
ML20054H755
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 06/15/1982
From: Holyoak R
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20054H756 List:
References
NUDOCS 8206240397
Download: ML20054H755 (2)


LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
3731982033R00 - NRC Website

text

.

'N Commonwealth Edison

) Rur:1Routa 01, Box 220 LaS:lla County Nucitar Station y

e y,

Marseilles, Illinois 61341 v

Tefephone 815/357-6761 June 15, 1982 James G. Keppler Regional Administrator Directorate of Regulatory Operations, Region lll U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Sir:

Reportable Occurrence Report #82-033/03L-0 Docket #050-373 is being submitted to your office in accordarice with LaSalle County Nuclear Power Station Technical Specification 6.6.B.2. (b), condi tions leading to operation in a degraded mode permitted by a limiting condition for operation or plant shutdown required by a limiting condition for operation.

Yib n.

A R. H. Holyoak Superintendent LaSalle County Station RHH/GW/psl Enclosure cc:

Director of Inspection & Enforcement Director of Management,Information & Program Control U. S. NRC Document Management Branch Inpo-Records Center File /NRC JON 211982 Y

9 P'umnu,

'y PDR

~

k a

1.

LER NUMBER:

82-033/03L-0 11.

LASALLE COUNTY STATION:

Unit 1 Ill. DOCKET NUMBER:

050-373 IV.

EVENT DESCRIPTION

Excessive leakage was found on the IB RHR Service Water Radiation Monitor Pump Housing, during normal operation.

V.

PROBABLE CONSEQUENCES OF OCCURRENCE The plant was in hot shutdown, Condition 3, at approx. 225 F.

Tech Spec 3 3 710 requires the IB RHR Service Water Radiation Monitor operable at all times.

There was no service water flow through the IB RHR Heat Exchanger at the time of occurrence.

There is no irradiated fuel presently in Unit 1.

Safe operation of the plant was maintained.

VI.

CAUSE

The IB RHR Service Water Radiation Monitor Sample pump is on GE Liquid Rack 1D18-J006, Cat. No. 828E144G001, Ser. No. 78-7807-2.

The pump is supplied by Prince Pump Company, Model E100-508.

The p robable-cause is a blown 0-ring or gasket at the pump housing.

The problem is being corrected under work request L 16245 V ll.

CORRECTIVE ACTION

a The IB RHR Service Water Radiation Monitor was taken out of service (1-1133-82) to stop the leakage. Tech spec 3 3 7.10 allows operation for up to 30 days.

Caution cards (1-454-82) were hung on the CSD RHR Service Water Pumps with the instructions " call Rad / Chem to start 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> samples when running B RHR Service Water".

An entry was made in the Degraded Equipcent Log. Work Request L16245 was completed on 6/9/82 by the installation of a new 0-ring in the IB RHR Service Water Radiation Monitor Pump Housing. The pump passed a functional leak test satisfactorily on 6/10/82.

l l

I Prepared by:

A. C. Settles i

I