| 05000368/LER-1980-001-03, /03L-0:on 800107,during Mode 1 Operation, Containment Isolation Valve 25V-5876-2 Failed to Close After Taking Samples from Safety Injection Tanks for Boron Analysis.Caused by Faulty Valve Position Indication | /03L-0:on 800107,during Mode 1 Operation, Containment Isolation Valve 25V-5876-2 Failed to Close After Taking Samples from Safety Injection Tanks for Boron Analysis.Caused by Faulty Valve Position Indication | |
| 05000313/LER-1980-001-03, /03L-0:on 800114,while Performing Surveillance Test,Hydrogen Purge Supply Isolation Valve CV-7444 Failed to Close.Caused by Oxidation on Torque Switch Contacts, Resulting in High Resistance to Closure.Contacts Cleaned | /03L-0:on 800114,while Performing Surveillance Test,Hydrogen Purge Supply Isolation Valve CV-7444 Failed to Close.Caused by Oxidation on Torque Switch Contacts, Resulting in High Resistance to Closure.Contacts Cleaned | |
| 05000368/LER-1980-002-03, /03L-0:on 800110,during Mode 1 Operation,Core Protection Calculator C Failed,Resulting in DNBR & Linear Power Density Trips in Channel C Primary Power Sys.Cause Undetermined.Sys Restarted During Failure Analysis | /03L-0:on 800110,during Mode 1 Operation,Core Protection Calculator C Failed,Resulting in DNBR & Linear Power Density Trips in Channel C Primary Power Sys.Cause Undetermined.Sys Restarted During Failure Analysis | |
| 05000313/LER-1980-002-03, /03L-0:on 800114,while Performing Surveillance Test,Hydrogen Purge Supply Isolation Valve CV-7448 Failed to Close.Caused by Oxidation on Torque Switch Contacts.Contacts Cleaned | /03L-0:on 800114,while Performing Surveillance Test,Hydrogen Purge Supply Isolation Valve CV-7448 Failed to Close.Caused by Oxidation on Torque Switch Contacts.Contacts Cleaned | |
| 05000313/LER-1980-003-01, /01T-0:on 800121,while at Cold Shutdown,Boron Buildups Identified on Loop B of Reactor Bldg Spray & Piping.Buildups Verified to Be Cracks in heat-affected Zone of Schedule 10 Pipe to Fitting Welds | /01T-0:on 800121,while at Cold Shutdown,Boron Buildups Identified on Loop B of Reactor Bldg Spray & Piping.Buildups Verified to Be Cracks in heat-affected Zone of Schedule 10 Pipe to Fitting Welds | |
| 05000313/LER-1980-003, Forwards LER 80-003/01T-0 | Forwards LER 80-003/01T-0 | |
| 05000368/LER-1980-003-03, /03L-0:on 800120,during Mode 3 Operation, Emergency Feedwater Flow Control Valve Failed to Close on Demand.Caused by Lack of Hydraulic Pressure | /03L-0:on 800120,during Mode 3 Operation, Emergency Feedwater Flow Control Valve Failed to Close on Demand.Caused by Lack of Hydraulic Pressure | |
| 05000368/LER-1980-004-03, /03L-0:on 800107,during Mode 1 Operation,Core Protection Calculator B Failed.Channel B DNBR & Linear Power Density Trips Were Bypassed Placing Reactor Trip Logic in two-out-of-three Trip Sequence.Cause Unknown | /03L-0:on 800107,during Mode 1 Operation,Core Protection Calculator B Failed.Channel B DNBR & Linear Power Density Trips Were Bypassed Placing Reactor Trip Logic in two-out-of-three Trip Sequence.Cause Unknown | |
| 05000313/LER-1980-004-03, /03L-0:on 800205,during Operational Test for Leak Rates,Reactor Bldg Ventilation Penetrations V1 & V2 Found Leaking in Excess of Tech Specs.Caused by Maladjusted Valve Seats.Valves Readjusted & Retested | /03L-0:on 800205,during Operational Test for Leak Rates,Reactor Bldg Ventilation Penetrations V1 & V2 Found Leaking in Excess of Tech Specs.Caused by Maladjusted Valve Seats.Valves Readjusted & Retested | |
| 05000313/LER-1980-004, Forwards LER 80-004/03L-0 | Forwards LER 80-004/03L-0 | |
| 05000368/LER-1980-005, Forwards Revised LER 80-005/03X-1 | Forwards Revised LER 80-005/03X-1 | |
| 05000368/LER-1980-005-03, /03L-0:on 800123,during Steady State Mode 1 Operation,Reactor Coolant Leakage Calculation Indicated Approx 3.6 Gpm Unidentified Leakage.Caused by Packing on Pressurized Spray Valves Leaking Excessively | /03L-0:on 800123,during Steady State Mode 1 Operation,Reactor Coolant Leakage Calculation Indicated Approx 3.6 Gpm Unidentified Leakage.Caused by Packing on Pressurized Spray Valves Leaking Excessively | |
| 05000313/LER-1980-005, Forwards LER 80-005/03L-0 | Forwards LER 80-005/03L-0 | |
| 05000313/LER-1980-005-03, /03L-0:on 800306,during Scheduled Surveillance Test of P7-A,CV-2617 Valve Failed to Close Remote Electrically.Caused by Valve Binding in Closed Position. Valve Stem Repacked & Proper Operation Verified | /03L-0:on 800306,during Scheduled Surveillance Test of P7-A,CV-2617 Valve Failed to Close Remote Electrically.Caused by Valve Binding in Closed Position. Valve Stem Repacked & Proper Operation Verified | |
| 05000313/LER-1980-006, Forwards LER 80-006/04L-0 | Forwards LER 80-006/04L-0 | |
| 05000368/LER-1980-006-03, /03L-0:on 800123,during Mode 1 Operation,Core Protection Calculator B Failed,Generating DNBR & Linear Power Density Trips in Primary Power Sys.Cause Undetermined. Channel Restarted & Declared Operable | /03L-0:on 800123,during Mode 1 Operation,Core Protection Calculator B Failed,Generating DNBR & Linear Power Density Trips in Primary Power Sys.Cause Undetermined. Channel Restarted & Declared Operable | |
| 05000313/LER-1980-006-04, /04L-0:on 800318,average Gross Release Rate for Jan-Mar 1980 Found to Be 4.3% of Max Permissible Concentration,Exceeding Tech Specs.Major Portion Caused by Reactor Bldg Purge in Jan | /04L-0:on 800318,average Gross Release Rate for Jan-Mar 1980 Found to Be 4.3% of Max Permissible Concentration,Exceeding Tech Specs.Major Portion Caused by Reactor Bldg Purge in Jan | |
| 05000313/LER-1980-007, Forwards LER 80-007/01T-0 | Forwards LER 80-007/01T-0 | |
| 05000313/LER-1980-007-99, Vendor Notified of Discrepancy Between Decay Heat Pump Specs & Parts Supplied. Potential Failure Feared.Tests & Performance History Indicate No Reliability Problems | Vendor Notified of Discrepancy Between Decay Heat Pump Specs & Parts Supplied. Potential Failure Feared.Tests & Performance History Indicate No Reliability Problems | |
| 05000313/LER-1980-007-01, /01T-0:on 800314,B&W Advised That Mating Wear Rings on Double Suction Pump Could Cause Pump Failure During Accident Conditions.Caused by Failure to Document Design Revision on Pump Design Drawings | /01T-0:on 800314,B&W Advised That Mating Wear Rings on Double Suction Pump Could Cause Pump Failure During Accident Conditions.Caused by Failure to Document Design Revision on Pump Design Drawings | |
| 05000368/LER-1980-007-03, /03L-0:on 800124,during Mode 1 Operation,Sodium Hydroxide Tank Level Found to Be 93% of Indicated Level. Following Calibr,Level Found to Be Below Tech Spec Limits. Cause Not Stated.Tank Levels Returned to Operable Limits | /03L-0:on 800124,during Mode 1 Operation,Sodium Hydroxide Tank Level Found to Be 93% of Indicated Level. Following Calibr,Level Found to Be Below Tech Spec Limits. Cause Not Stated.Tank Levels Returned to Operable Limits | |
| 05000313/LER-1980-008-03, /03L-0:on 800324,while Performing Surveillance Test,Bypass Flow Was Observed to Be Zero Due to Failure of CV-2126 in Closed Position.Caused by Blown Control Fuse.Fuse Replaced & Valve Proved Operable | /03L-0:on 800324,while Performing Surveillance Test,Bypass Flow Was Observed to Be Zero Due to Failure of CV-2126 in Closed Position.Caused by Blown Control Fuse.Fuse Replaced & Valve Proved Operable | |
| 05000368/LER-1980-008-03, /03L-0:on 800128,during Mode 1 Operation,Core Protection Calculator B Failed.Cause Not Determined.Core Protection Calculator B Restored & Functionally Tested | /03L-0:on 800128,during Mode 1 Operation,Core Protection Calculator B Failed.Cause Not Determined.Core Protection Calculator B Restored & Functionally Tested | |
| 05000313/LER-1980-008, Forwards LER 80-008/03L-0 | Forwards LER 80-008/03L-0 | |
| 05000313/LER-1980-009-03, /03L-0:on 800328,while Performing Surveillance Test,Lead Hydrogen Purge Supply fan,VSF-30A Tripped on Overload.Caused by Check Valve HPA-5 Being Stuck,Due to Corrosion from Seal Water Leaking Onto Valve | /03L-0:on 800328,while Performing Surveillance Test,Lead Hydrogen Purge Supply fan,VSF-30A Tripped on Overload.Caused by Check Valve HPA-5 Being Stuck,Due to Corrosion from Seal Water Leaking Onto Valve | |
| 05000313/LER-1980-009, Forwards LER 80-009/03L-0 | Forwards LER 80-009/03L-0 | |
| 05000368/LER-1980-009, Forwards LER 80-009/03L-0 | Forwards LER 80-009/03L-0 | |
| 05000368/LER-1980-009-03, /03L-0:on 800129,during Mode 3 Operation Following Reactor Trip from 100% power,I-131 Value of 1.67 Uci Was Observed.Caused by Expected Spike Following Reactor Trip.No Corrective Actions Necessary | /03L-0:on 800129,during Mode 3 Operation Following Reactor Trip from 100% power,I-131 Value of 1.67 Uci Was Observed.Caused by Expected Spike Following Reactor Trip.No Corrective Actions Necessary | |
| 05000368/LER-1980-010-03, /03L-0:on 800212,during Mode 5 Operation, Discovered That Tech Spec 24-month Local Leak Rate Surveillance Requirements Had Not Been Performed.Caused by Confusion Over 24-month Surveillance Interval | /03L-0:on 800212,during Mode 5 Operation, Discovered That Tech Spec 24-month Local Leak Rate Surveillance Requirements Had Not Been Performed.Caused by Confusion Over 24-month Surveillance Interval | |
| 05000313/LER-1980-010-03, /03L-0:on 800307,sys Reviews Per IE Bulletin 79-14 Found Hangers Inoperable.Cause Not Stated.Hangers Repaired & Mods Made by Revision to DCP 80-D-1207.List of Hangers Encl | /03L-0:on 800307,sys Reviews Per IE Bulletin 79-14 Found Hangers Inoperable.Cause Not Stated.Hangers Repaired & Mods Made by Revision to DCP 80-D-1207.List of Hangers Encl | |
| 05000313/LER-1980-010, Forwards LER 80-010/03L-0 | Forwards LER 80-010/03L-0 | |
| 05000313/LER-1980-011, Forwards LER 80-011/03L-0 | Forwards LER 80-011/03L-0 | |
| 05000313/LER-1980-011-03, /03L-0:on 800401,based on Sys Review Per IE Bulletin 79-14,certain Hangers Declared Inoperable.Cause Not Stated.Hangers Repaired or Modified within Required Time Limit on Affected Svc Water & Main Steam Sys | /03L-0:on 800401,based on Sys Review Per IE Bulletin 79-14,certain Hangers Declared Inoperable.Cause Not Stated.Hangers Repaired or Modified within Required Time Limit on Affected Svc Water & Main Steam Sys | |
| 05000368/LER-1980-011-03, /03L-0:on 800214,during Mode 5 Operation,While Performing Local Leak Rate Test,Five Containment Penetration Leak Rates Exceeded Tech Specs.Caused by Corrosion Buildup on Seating Surface or Valves Needing Adjustment | /03L-0:on 800214,during Mode 5 Operation,While Performing Local Leak Rate Test,Five Containment Penetration Leak Rates Exceeded Tech Specs.Caused by Corrosion Buildup on Seating Surface or Valves Needing Adjustment | |
| 05000368/LER-1980-012, Forwards Updated LER 80-012/03X-2 | Forwards Updated LER 80-012/03X-2 | |
| 05000313/LER-1980-012, Forwards LER 80-012/03L-0 | Forwards LER 80-012/03L-0 | |
| 05000313/LER-1980-012-03, /03L:on 800406,while Performing Monthly Inservice Valve Stroke Test,Emergency Feedwater Supply valves,CV2667 & CV2617,failed to Fully Open.Caused by Binding Due to Loose Bolts Securing Actuator | /03L:on 800406,while Performing Monthly Inservice Valve Stroke Test,Emergency Feedwater Supply valves,CV2667 & CV2617,failed to Fully Open.Caused by Binding Due to Loose Bolts Securing Actuator | |
| 05000368/LER-1980-012-03, /03L-0:on 800222,during Mode 5 Operation,While Performing Surveillance Tests on Diesel Generator 1,unit Became Inoperable.Caused by Broken Generator Rotor Shaft in Area of Motor End Bearing Housing.Analyzing Exact Cause | /03L-0:on 800222,during Mode 5 Operation,While Performing Surveillance Tests on Diesel Generator 1,unit Became Inoperable.Caused by Broken Generator Rotor Shaft in Area of Motor End Bearing Housing.Analyzing Exact Cause | |
| 05000313/LER-1980-013, Forwards LER 80-013/03L-0 | Forwards LER 80-013/03L-0 | |
| 05000368/LER-1980-013-03, /03L-0:on 800229,during Mode 5 Operation,Reactor Cooling Sys Chloride Concentration Found to Be Approx 0.5 Ppm,Violating Tech Specs.Probably Caused by Batch Contaminated During Maint on Safety Injection Check Valve | /03L-0:on 800229,during Mode 5 Operation,Reactor Cooling Sys Chloride Concentration Found to Be Approx 0.5 Ppm,Violating Tech Specs.Probably Caused by Batch Contaminated During Maint on Safety Injection Check Valve | |
| 05000368/LER-1980-013, Forwards LER 80-013/03L-0 | Forwards LER 80-013/03L-0 | |
| 05000313/LER-1980-013-03, /03L-0:on 800407,during Reactor Trip of Offsite Power,High Pressure Injection Was Manually Initiated & CV-1227 High Pressure Injection Valve,Loop B Failed to Open on Demand.Caused by Stuck Engaging Lever | /03L-0:on 800407,during Reactor Trip of Offsite Power,High Pressure Injection Was Manually Initiated & CV-1227 High Pressure Injection Valve,Loop B Failed to Open on Demand.Caused by Stuck Engaging Lever | |
| 05000368/LER-1980-014-03, /03L-0:on 800313,during Mode 5 Operation,Local Leak Rate Testing at Containment Penetration 2V2 Revealed Excessive Leak Rate Between Valve Actuation & Heatup Processes.Caused by Partially Open Inside Isolation Valve | /03L-0:on 800313,during Mode 5 Operation,Local Leak Rate Testing at Containment Penetration 2V2 Revealed Excessive Leak Rate Between Valve Actuation & Heatup Processes.Caused by Partially Open Inside Isolation Valve | |
| 05000368/LER-1980-014, Forwards LER 80-014/03L-0 | Forwards LER 80-014/03L-0 | |
| 05000313/LER-1980-014, Forwards LER 80-014/03L-0 | Forwards LER 80-014/03L-0 | |
| 05000313/LER-1980-014-03, /03X-1:on 800415,fire & Smoke Detector Testing Not Completed within Surveillance Interval Due to High Radiation Level.Detectors Tested at Cold Shutdown.Tech Spec 4.19 Revised | /03X-1:on 800415,fire & Smoke Detector Testing Not Completed within Surveillance Interval Due to High Radiation Level.Detectors Tested at Cold Shutdown.Tech Spec 4.19 Revised | |
| 05000368/LER-1980-015, Forward LER 80-015/99X-0 | Forward LER 80-015/99X-0 | |
| 05000368/LER-1980-015-99, /99X-0:on 800129,during Recovery from Planned Transient,Rcs Depressurized to Min of 1,350 Psia.Caused by Pressurizer Spray Valve 2CV-4651 & Steam Dump & Bypass Valve 2CV-0301 Not Fully Closing on Demand.Valves Modified | /99X-0:on 800129,during Recovery from Planned Transient,Rcs Depressurized to Min of 1,350 Psia.Caused by Pressurizer Spray Valve 2CV-4651 & Steam Dump & Bypass Valve 2CV-0301 Not Fully Closing on Demand.Valves Modified | |
| 05000313/LER-1980-015, Forwards LER 80-015/01T-0 | Forwards LER 80-015/01T-0 | |
| 05000313/LER-1980-015-01, /01T-0:on 800510,changes in Seal Pressure & Makeup Tank Level Occurred During Steady State Power Operation. Caused by Rx Coolant Pump Seal C.Seal Cartridge Rebuilt & Seal Failure Being Investigated | /01T-0:on 800510,changes in Seal Pressure & Makeup Tank Level Occurred During Steady State Power Operation. Caused by Rx Coolant Pump Seal C.Seal Cartridge Rebuilt & Seal Failure Being Investigated | |