Finding | |
|---|---|
| Title | Failure to Establish Appropriate Instructions |
| Description | The team identified a White violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, involving the failure to establish appropriate instructions for performing maintenance activities on safetyrelated 125 Vdc station battery Breaker 2D201. As a result, during replacement of the breaker in March 2004 electrical connection integrity was not adequate to ensure that the equipment would be able to perform its safety function. This condition existed for approximately four years. This issue was entered into the licensees corrective action program as Root Cause Evaluation 800121216. The finding is greater than minor because it is associated with the equipment performance attribute of the mitigating systems cornerstone and affects the associated cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The final significance determination performed by the senior reactor analyst and approved by the NRC significance and enforcement review panel determined the finding was of low to moderate safety significance (White). This finding has a crosscutting aspect in the area of human performance associated with resources because the licensee failed to establish adequate procedures and programs related to electrical connection integrity H.2(c) (Sections 2.1.5 and 3.5) |
| Site: | San Onofre |
|---|---|
| Report | IR 05000361/2008013 Section 4OA5 |
| Date counted | Dec 31, 2008 (2008Q4) |
| Type: | Violation: White |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 93812 |
| Inspectors (proximate) | S Graves G Skinner G Warnick M Baquera B Collins |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - San Onofre - IR 05000361/2008013 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (San Onofre) @ 2008Q4
Self-Identified List (San Onofre)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||