| | | Reporting criterion |
|---|
| 05000344/LER-1982-001-01, /01L-0:on 820118,discovered That Emergency Diesel Generator 2 Effectively Inoperable When 120-volt Ac Perferred Instrument Buses Y22 or Y24 Are Powered from Nonpreferred Instrument Bus Y02 | /01L-0:on 820118,discovered That Emergency Diesel Generator 2 Effectively Inoperable When 120-volt Ac Perferred Instrument Buses Y22 or Y24 Are Powered from Nonpreferred Instrument Bus Y02 | |
| 05000344/LER-1982-001, Updated LER 82-001/01T-1:on 820118,engineering Investigation Discovered That Emergency Diesel Generator 2 Become Inoperable from 811201-820104 Due to Powering of Instrument Buses Y24 from Nonpreferred Bus Y02 | Updated LER 82-001/01T-1:on 820118,engineering Investigation Discovered That Emergency Diesel Generator 2 Become Inoperable from 811201-820104 Due to Powering of Instrument Buses Y24 from Nonpreferred Bus Y02 | |
| 05000344/LER-1982-002-03, /03L-0:on 820109,following Reactor Trip,Both Source Instrumentation Channels Failed to Energize.Caused by Improper Actuation of Instrument Crowbar Circuit.Channels Energized When Power Fuses Were Removed & Reinserted | /03L-0:on 820109,following Reactor Trip,Both Source Instrumentation Channels Failed to Energize.Caused by Improper Actuation of Instrument Crowbar Circuit.Channels Energized When Power Fuses Were Removed & Reinserted | |
| 05000344/LER-1982-002, Forwards LER 82-002/03L-0.Detailed Event Analysis Encl | Forwards LER 82-002/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-003-03, /03L-0:on 820106,personnel Noted Noisy Pump & Low Flow Through Process Radiation monitor-1 Pump (PRM-1). Caused by Thrown Vane within Sealed Pump Unit.Pump Replaced & Sys Returned to Normal Operation | /03L-0:on 820106,personnel Noted Noisy Pump & Low Flow Through Process Radiation monitor-1 Pump (PRM-1). Caused by Thrown Vane within Sealed Pump Unit.Pump Replaced & Sys Returned to Normal Operation | |
| 05000344/LER-1982-003, Forwards LER 82-003/03L-0.Detailed Event Analysis Encl | Forwards LER 82-003/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-004-03, /03L-0:on 820302,B Train Containment Spray & Centrifugal Charging Pump Control Switches Were Left in Pull Lock After Surveillance Testing of DBA Sequencer.Caused by Personnel Error | /03L-0:on 820302,B Train Containment Spray & Centrifugal Charging Pump Control Switches Were Left in Pull Lock After Surveillance Testing of DBA Sequencer.Caused by Personnel Error | |
| 05000344/LER-1982-004, Forwards LER 82-004/03L-0.Detailed Event Analysis Encl | Forwards LER 82-004/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-005, Forwards LER 82-005/03L-0.Detailed Event Analysis Encl | Forwards LER 82-005/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-005-03, /03L-0:on 820331,failure to Perform Component Cooling Water Valve Cycling at Required Frequency Discovered.Caused by Personnel Error.Schedule Corrected | /03L-0:on 820331,failure to Perform Component Cooling Water Valve Cycling at Required Frequency Discovered.Caused by Personnel Error.Schedule Corrected | |
| 05000344/LER-1982-006, Forwards LER 82-006/01T-0.Detailed Event Analysis Encl | Forwards LER 82-006/01T-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-006-01, /01T-0:on 820426,17 Fuel Assemblies Found to Have Abnormal Clad Degradation.Caused by Water Jet Impingement & Induced Vibration on Fuel Rods.Fuel Assemblies Modified Using Stainless Steel Pins | /01T-0:on 820426,17 Fuel Assemblies Found to Have Abnormal Clad Degradation.Caused by Water Jet Impingement & Induced Vibration on Fuel Rods.Fuel Assemblies Modified Using Stainless Steel Pins | |
| 05000344/LER-1982-007, Updated LER 82-007/01T-0:on 820514,during Review of Revised Containment DBA Analysis,Nonconservative Spray Modeling Error Identified in Model Used to Justify Tech Spec 3.6.1.4 Re Max Positive Containment Operating Pressure | Updated LER 82-007/01T-0:on 820514,during Review of Revised Containment DBA Analysis,Nonconservative Spray Modeling Error Identified in Model Used to Justify Tech Spec 3.6.1.4 Re Max Positive Containment Operating Pressure | |
| 05000344/LER-1982-008-03, /03L-0:on 820424,battery Charger D23 in 125-volt Dc Sys Failed to Pass Annual Performance Test.Caused by Random Failure of Diode in Circuitry.Diode Replaced & Test Completed Successfully | /03L-0:on 820424,battery Charger D23 in 125-volt Dc Sys Failed to Pass Annual Performance Test.Caused by Random Failure of Diode in Circuitry.Diode Replaced & Test Completed Successfully | |
| 05000344/LER-1982-008, Forwards LER 82-008/03L-0.Detailed Event Analysis Encl | Forwards LER 82-008/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-009-03, /03L-0:on 820528,chemical & Vol Control Sys B Hut Partially Collapsed When Pumped to Spent Fuel Pit.Caused by Water Buildup in Sys,Allowing Partial Vacuum to Be Drawn on Tank.Hut Repaired | /03L-0:on 820528,chemical & Vol Control Sys B Hut Partially Collapsed When Pumped to Spent Fuel Pit.Caused by Water Buildup in Sys,Allowing Partial Vacuum to Be Drawn on Tank.Hut Repaired | |
| 05000344/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl | Forwards LER 82-009/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-010-03, /03L-0:on 820610,following Fuel Removal from Core, Spent Fuel Pool Level Was Inadvertently Pumped Below Min Limit.Caused by Personnel Error.Level Raised by Opening Transfer Canal Door.Level Switch Arm Straightened | /03L-0:on 820610,following Fuel Removal from Core, Spent Fuel Pool Level Was Inadvertently Pumped Below Min Limit.Caused by Personnel Error.Level Raised by Opening Transfer Canal Door.Level Switch Arm Straightened | |
| 05000344/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl. Corrected Copy | Forwards LER 82-010/03L-0.Detailed Event Analysis Encl. Corrected Copy | |
| 05000344/LER-1982-011-03, /03T-0:on 820608,during Refueling,Safety Injection/Rcs Thermal Sleeve Matl Discovered Below Lower Core Plate.Caused by Vibration.Affected Sleeves Removed. Similar Thermal Sleeve Nozzles Radiographed | /03T-0:on 820608,during Refueling,Safety Injection/Rcs Thermal Sleeve Matl Discovered Below Lower Core Plate.Caused by Vibration.Affected Sleeves Removed. Similar Thermal Sleeve Nozzles Radiographed | |
| 05000344/LER-1982-011, Forwards LER 82-011/03T-0.Detailed Event Analysis Encl | Forwards LER 82-011/03T-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-019, Forwards LER 82-019/03L-0.Detailed Event Analysis Encl | Forwards LER 82-019/03L-0.Detailed Event Analysis Encl | |
| 05000344/LER-1982-019-03, /03L-0:on 821007,safety Injection & Centrifugal Charging Pump Lube Oil Cooler Svc Water Valves Found W/O Locking Devices Nor Subjected to Surveillance Check.Caused by Valves Not Shown on Piping Instrument Diagram | /03L-0:on 821007,safety Injection & Centrifugal Charging Pump Lube Oil Cooler Svc Water Valves Found W/O Locking Devices Nor Subjected to Surveillance Check.Caused by Valves Not Shown on Piping Instrument Diagram | |
| 05000344/LER-1982-020-03, /03L-0:on 821013,manual Filter Inlet Damper on Train a Control Room Emergency Ventilation Sys Found Closed, Isolating Fan VC-142A Suction Path from Control Room.Caused by Loose Setscrew.Improved Attachment Method Implemented | /03L-0:on 821013,manual Filter Inlet Damper on Train a Control Room Emergency Ventilation Sys Found Closed, Isolating Fan VC-142A Suction Path from Control Room.Caused by Loose Setscrew.Improved Attachment Method Implemented | |
| 05000344/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis Encl | Forwards LER 82-020/03L-0.Detailed Event Analysis Encl | |