Title | Failure to Follow Procedure for Flow Accelerated Corrosion Program |
Description | The inspectors documented a self-revealing finding for the failure to properly implement the flow accelerated corrosion control program. Consequently, a nonsafety-related extraction steam drain line failed because of flow accelerated corrosion. Engineers had identified the line as being vulnerable to flow accelerated corrosion but did not monitor it. Engineers also failed to integrate relevant industry operating experience into the program. Operators had to reduce Unit 2 power and take the turbine off line in response to the event. The licensee entered this issue into their corrective action program as Condition Report ANO-2-2009-0319. The performance deficiency was more than minor because it affected the equipment performance attribute of the Initiating Events Cornerstone, and it directly affected the cornerstone objective to limit the likelihood of those events that upset plant stability during power operations. Using Inspection Manual Chapter 0609, Significance Determination Process, Phase 1 Worksheet, this finding was determined to have very low safety significance because it did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would not be available. The finding had a crosscutting aspect in the area of Problem Identification and Resolution associated with Operating Experience P.2(b), in that licensee personnel failed to implement and institutionalize operating experience through changes to station processes and procedures |
Site: | Arkansas Nuclear ![]() |
---|---|
Report | IR 05000313/2009002 Section 4OA3 |
Date counted | Mar 31, 2009 (2009Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | K Clayton A Sanchez J Josey J Clark S Rotton |
CCA | P.5, Operating Experience |
INPO aspect | CL.1 |
' | |
Finding - Arkansas Nuclear - IR 05000313/2009002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Arkansas Nuclear) @ 2009Q1
Self-Identified List (Arkansas Nuclear)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||