Finding | |
---|---|
Title | Inadequate Service Air Compressor Torquie Value Led to Loss of Control Rod Drive Cooling and Manual Reactor Trip |
Description | The inspectors documented a self-revealing finding associated with the Unit 1 February 5, 2009, manual reactor trip. The unit was manually tripped because control rod drive mechanism cooling was lost when the head gasket on Service Air Compressor C-3A failed. The failure of the head gasket was caused by a reduction in torque applied on the head gasket bolts during maintenance. The applied torque values were lower than the torque values recommended by the vendor. The licensee entered this issue into their corrective action program as Condition Report ANO-1-2009-0225. The performance deficiency was more than minor because it was associated with the design control attribute of the Initiating Events Cornerstone and it directly affected the cornerstone objective to limit the likelihood of those events that upset plant stability during power operations. Using Inspection Manual Chapter 0609, Significance Determination Process, Phase 1 Worksheet, this finding was determined to have very low safety significance because it did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would not be available. This finding was determined not to have a crosscutting aspect because the decision to lower the torque value was made in 2001 and was not indicative of current plant performance |
Site: | Arkansas Nuclear |
---|---|
Report | IR 05000313/2009002 Section 4OA3 |
Date counted | Mar 31, 2009 (2009Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | K Clayton A Sanchez J Josey J Clark S Rotton |
INPO aspect | |
' | |
Finding - Arkansas Nuclear - IR 05000313/2009002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Arkansas Nuclear) @ 2009Q1
Self-Identified List (Arkansas Nuclear)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||