| Q | CCA | Title |
---|
05000305/FIN-2008005-02 | 2008Q4 | | Emergency Diesel Generator Room Cooling Fan Testing Deficiences |
05000305/FIN-2008005-03 | 2008Q4 | P.1 P.1(a) | Failure to Transfer Turbine Valve Testing Requirements into the USAR |
05000305/FIN-2009002-06 | 2009Q1 | | Seismic Monitoring System Repeatedly Fails Surveillance |
05000305/FIN-2009002-01 | 2009Q1 | | Potential Debris Could Clog a Drain Credited During Internal Floods |
05000305/FIN-2009002-08 | 2009Q1 | P.3 | Steam Exclusion Door Failure Results in Multiple Safety Systems Being Declared Inoperable |
05000305/FIN-2009002-03 | 2009Q1 | P.2 | Inappropriate Application of a Dedicated Operator During a CCW Surveillance |
05000305/FIN-2009002-05 | 2009Q1 | | Emergency Diesel Generator (EDG) Air System May Not Be Appropriately Qualified |
05000305/FIN-2009002-04 | 2009Q1 | | Multiple Component Cooling Water Pipes in Close Proximity to High Energy Feedwater Lines |
05000305/FIN-2009002-02 | 2009Q1 | | Inappropriate Application of a Dedicated Operator During a CCW Surveillance |
05000305/FIN-2009002-07 | 2009Q1 | P.3 | Siphon Line Which Interconnected Two Diesel Generator Emergency Fuel Oil Storage Tanks Was Not Functioning as Designed |
05000305/FIN-2009003-03 | 2009Q2 | | Failure to Ensure That Motor Control Center Control Circuits have Adequate Voltage To Operate During Design Basis Accident Conditions |
05000305/FIN-2009003-02 | 2009Q2 | P.4 | Emergency Diesl Generator Air System May Not Be Appropriately Qualified |
05000305/FIN-2009003-01 | 2009Q2 | | Emergency Diesel Generator Fuel Oil Storage and Day Tank Vent Line Tornado Qualification |
05000305/FIN-2009003-05 | 2009Q2 | | Inadequate Calibration of Radiation Monitor R-19 |
05000305/FIN-2009003-06 | 2009Q2 | P.5 | Failed Backdraft Damper Renders Containment Fan Coil Unit Inoperable |
05000305/FIN-2009003-07 | 2009Q2 | H.7 | Failure to Update Procedures As Required by Commitments |
05000305/FIN-2009003-04 | 2009Q2 | P.4 | Seismic Monitoring System Repeatedly Fails Surveillance |
05000305/FIN-2009006-03 | 2009Q3 | | Non-Conservative Main Steam Line Break Analysis |
05000305/FIN-2009006-01 | 2009Q3 | P.1 | Improper Application of 440 Vac Rated Motors |
05000305/FIN-2009006-05 | 2009Q3 | P.2 | Inadequate Procedure for a Battery Room Flooding Event |
05000305/FIN-2009006-02 | 2009Q3 | H.2 | Inaccurate Minimum Low Head Safety Injection Flow Specified in Emergency Operating Procedure |
05000305/FIN-2009406-01 | 2009Q3 | H.9 | Security |
05000305/FIN-2009004-05 | 2009Q3 | H.2 | Inadequate Design Analysis for 105-ton Transfer Cask-Lifting Beam |
05000305/FIN-2009004-03 | 2009Q3 | | Failure to Adequately Analyze the Automatic Fast Transfer Feature That Allowed Operation with Both 4 Kv SAFETY-RELATED Buses 1-5 and 1-6 Connected to the Rat |
05000305/FIN-2009004-02 | 2009Q3 | H.7 | Containment Isolation Valve Inoperable with No Technical Specification Action Requirement Entry |
05000305/FIN-2009004-04 | 2009Q3 | | Potential Unreported Safety System Functional Failures |
05000305/FIN-2009004-01 | 2009Q3 | | Technical Specification Action Requirements During a Leak in a Containment Fan Coil Unit Service Water Line |
05000305/FIN-2009006-04 | 2009Q3 | H.14 | Inadequate 50.59 Evaluation of Shutdown Loss of Coolant Accident Procedure |
05000305/FIN-2009004-06 | 2009Q3 | | Failure to Follow ISFSI Loading Procedure Step |