| 05000275/LER-1983-001-03, /03L-0:on 830107,during Recorder Check Prior to Fuel Load,Steam Generator Blowdown Multipoint Flow Recorder 1-71 Discovered Inoperable.Caused by Broken Print Head Drive String.String Replaced | /03L-0:on 830107,during Recorder Check Prior to Fuel Load,Steam Generator Blowdown Multipoint Flow Recorder 1-71 Discovered Inoperable.Caused by Broken Print Head Drive String.String Replaced | |
| 05000275/LER-1983-002, Forwards LER 83-002/03L-0 | Forwards LER 83-002/03L-0 | |
| 05000275/LER-1983-002-03, /03L-0:on 830113,prior to Fuel Load,Liquid Radwaste Effluent Flow Recorder Discovered Inoperable During Discharge of Tank in Liquid Radwaste Sys.Caused by Out of Tolerance Flow Transmitter.Transmitter Cleaned | /03L-0:on 830113,prior to Fuel Load,Liquid Radwaste Effluent Flow Recorder Discovered Inoperable During Discharge of Tank in Liquid Radwaste Sys.Caused by Out of Tolerance Flow Transmitter.Transmitter Cleaned | |
| 05000275/LER-1983-003-03, /03L-0:on 830414,control Operator Unable to Achieve Satisfactory Check Source Reading on Liquid Radwaste Discharge Line Radiation Monitor (RE-18).Caused by Missing Check Source from Monitoring Mechanism | /03L-0:on 830414,control Operator Unable to Achieve Satisfactory Check Source Reading on Liquid Radwaste Discharge Line Radiation Monitor (RE-18).Caused by Missing Check Source from Monitoring Mechanism | |
| 05000275/LER-1983-005-04, /04X-0:on 830502,prior to Fuel Load & Following Coalinga Earthquake,Unusual Event Declared Based on Earthquake Motion Felt at Plant w/.5 G Full Upscale Indication.Caused by Faulty Reset Switch | /04X-0:on 830502,prior to Fuel Load & Following Coalinga Earthquake,Unusual Event Declared Based on Earthquake Motion Felt at Plant w/.5 G Full Upscale Indication.Caused by Faulty Reset Switch | |
| 05000275/LER-1983-006-01, /01T-0:on 830510,possible Undersize Condition Found on Weld WIB-RC 2-17.Cause Under Investigation.Below Min Wall Thickness Welds to Be Analyzed or Repaired Per ASME Section XI | /01T-0:on 830510,possible Undersize Condition Found on Weld WIB-RC 2-17.Cause Under Investigation.Below Min Wall Thickness Welds to Be Analyzed or Repaired Per ASME Section XI | |
| 05000275/LER-1983-006, Updated LER 83-006/01T-1:on 830510,possible Undersize Condition Discovered on Reactor Coolant Piping Weld WIB-RC-2-17 During Ultrasonic Testing.Weld Confirmed to Be Above Min Wall Requirements Mechanically | Updated LER 83-006/01T-1:on 830510,possible Undersize Condition Discovered on Reactor Coolant Piping Weld WIB-RC-2-17 During Ultrasonic Testing.Weld Confirmed to Be Above Min Wall Requirements Mechanically | |
| 05000275/LER-1983-007-01, /01T-0:on 830509,water Leaked from Weld Area of Reinforcement Pad on Branch Connection to non-vital Loop C Component Cooling Water Sys.Caused by Flaw in Root Pass of Shop Weld.Repairs to Be Made | /01T-0:on 830509,water Leaked from Weld Area of Reinforcement Pad on Branch Connection to non-vital Loop C Component Cooling Water Sys.Caused by Flaw in Root Pass of Shop Weld.Repairs to Be Made | |
| 05000275/LER-1983-007, Updated LER 83-007/01T-1:on 830509,during Welding of Reinforcement Pad on Branch Connection to Loop C Component Cooling Water Sys,Water Leaked from Weld Area.Caused by Grinding on Fillet Overweld.Overweld Removed | Updated LER 83-007/01T-1:on 830509,during Welding of Reinforcement Pad on Branch Connection to Loop C Component Cooling Water Sys,Water Leaked from Weld Area.Caused by Grinding on Fillet Overweld.Overweld Removed | |
| 05000275/LER-1983-008-03, /03L-0:on 830510,const Electrician Inadvertently Deenergized New Fuel Storage Area Monitor (RM-5) & Oily Water Separator Effluent Line Monitor (RM-3),resulting in Loss of Bus 1-1A.Caused by Lifting Wrong Wire | /03L-0:on 830510,const Electrician Inadvertently Deenergized New Fuel Storage Area Monitor (RM-5) & Oily Water Separator Effluent Line Monitor (RM-3),resulting in Loss of Bus 1-1A.Caused by Lifting Wrong Wire | |
| 05000275/LER-1983-009-03, /03L-0:on 830505,power Switch to Plant Vent Iodine Sampler (RE-24) Found in Off Position.Power Switch Inadvertently Moved to Off Position During Const.Const Personnel Cautioned | /03L-0:on 830505,power Switch to Plant Vent Iodine Sampler (RE-24) Found in Off Position.Power Switch Inadvertently Moved to Off Position During Const.Const Personnel Cautioned | |
| 05000275/LER-1983-010-03, /03L-0:on 830514,prior to Fuel Load,Power to All Main Control Room Annunciators Lost During Const in Annunciator Cabinets.Caused by Electrician Touching Hot Wire to Ground,Short Circuiting Panel | /03L-0:on 830514,prior to Fuel Load,Power to All Main Control Room Annunciators Lost During Const in Annunciator Cabinets.Caused by Electrician Touching Hot Wire to Ground,Short Circuiting Panel | |
| 05000275/LER-1983-011-03, /03L-0:on 830518,prior to Fuel Load,Discovered Source Check of Oily Water Separator Effluent Line Monitor Not Performed Monthly.Caused by Administrative Error During Procedure Rev | /03L-0:on 830518,prior to Fuel Load,Discovered Source Check of Oily Water Separator Effluent Line Monitor Not Performed Monthly.Caused by Administrative Error During Procedure Rev | |
| 05000275/LER-1983-012-03, /03L-0:on 830518,prior to Fuel Load,Air Sample Pumps for Plant Vent Radiation Monitors Found Tripped.Caused by Excessive Debris Clogging Radiation Monitor Filter Paper Due to Const Activities | /03L-0:on 830518,prior to Fuel Load,Air Sample Pumps for Plant Vent Radiation Monitors Found Tripped.Caused by Excessive Debris Clogging Radiation Monitor Filter Paper Due to Const Activities | |
| 05000275/LER-1983-013-03, /03L-0:on 830518,prior to Fuel Load,Air Sample Pumps for Plant Vent Radiation Monitors RM-14A & B Inoperable.Caused by Removal of Control & Instrument Fuses for Work Inside RM28 a & B Cabinet | /03L-0:on 830518,prior to Fuel Load,Air Sample Pumps for Plant Vent Radiation Monitors RM-14A & B Inoperable.Caused by Removal of Control & Instrument Fuses for Work Inside RM28 a & B Cabinet | |
| 05000275/LER-1983-014-01, /01T-0:on 830526,during Adjustment of Limitorque Operator,Binding of Torque Switch Observed.Cause Under Investigation.Torque Switch Mounting Bolts Substituted for Original Bolts | /01T-0:on 830526,during Adjustment of Limitorque Operator,Binding of Torque Switch Observed.Cause Under Investigation.Torque Switch Mounting Bolts Substituted for Original Bolts | |
| 05000275/LER-1983-014, Updated LER 83-014/01T-1:on 830526,torque Switch Binding Observed During Maint on Limitorque Operator.Caused by Excessive Size of Mounting Screw Heads.Screws Replaced | Updated LER 83-014/01T-1:on 830526,torque Switch Binding Observed During Maint on Limitorque Operator.Caused by Excessive Size of Mounting Screw Heads.Screws Replaced | |
| 05000275/LER-1983-015-03, /03L-0:on 830526,annunciator Window in Channel Functional Test Procedure for Vent Iodine Sampler RM-24 Failed to Alarm.Caused by Lack of Updated Procedures to Reflect Design Change.Procedure Updated | /03L-0:on 830526,annunciator Window in Channel Functional Test Procedure for Vent Iodine Sampler RM-24 Failed to Alarm.Caused by Lack of Updated Procedures to Reflect Design Change.Procedure Updated | |
| 05000275/LER-1983-016-03, /03L-0:on 830606,plant Vent Flow Rate Monitor FR-12 Discorerd Deenergized.Caused by Personnel Error. Personnel Cautioned to Research Clearance Requests Prior to Approval | /03L-0:on 830606,plant Vent Flow Rate Monitor FR-12 Discorerd Deenergized.Caused by Personnel Error. Personnel Cautioned to Research Clearance Requests Prior to Approval | |
| 05000275/LER-1983-017-03, /03L-0:on 830706,power Supply Circuit Breaker for Oily Water Separator Effluent Flow Monitor (FR-251) Tripped Open & Would Not Reset.Cause Undetermined.Breaker Replaced | /03L-0:on 830706,power Supply Circuit Breaker for Oily Water Separator Effluent Flow Monitor (FR-251) Tripped Open & Would Not Reset.Cause Undetermined.Breaker Replaced | |
| 05000275/LER-1983-018-03, /03L-0:on 830715,discovered Raw Water Reservoir Isolated from Fire Suppression Header,Rendering Fire Suppression Water Sys Inoperable.Caused by Failure to List Valve MU-O-274 on Checklist | /03L-0:on 830715,discovered Raw Water Reservoir Isolated from Fire Suppression Header,Rendering Fire Suppression Water Sys Inoperable.Caused by Failure to List Valve MU-O-274 on Checklist | |
| 05000275/LER-1983-019-03, Welding Performed on Additive Tank W/O First Draining Tank of Sodium Hydroxide Solution.Caused by Lack of Communication to Field.No Evidence of Cracks or Corrosion Observed | Welding Performed on Additive Tank W/O First Draining Tank of Sodium Hydroxide Solution.Caused by Lack of Communication to Field.No Evidence of Cracks or Corrosion Observed | |
| 05000275/LER-1983-020-03, /03L-0:on 830723,prior to Fuel Load,Gaseous Radwaste Sys Noble Gas Activity Monitor RM-22 Failed in Svc. Caused by Detector Tube Failure Due to Natural end-of-life. New Tube Installed & Monitor Tested | /03L-0:on 830723,prior to Fuel Load,Gaseous Radwaste Sys Noble Gas Activity Monitor RM-22 Failed in Svc. Caused by Detector Tube Failure Due to Natural end-of-life. New Tube Installed & Monitor Tested | |
| 05000275/LER-1983-021-03, /03L-0:on 830925,primary Meteorological Tower Air Temp Aspirator Failed,Rendering Differential Air Temp Sensing Instrument Inoperable for 48 H.Caused by Electrical Connector Short Due to Exposure to Environ | /03L-0:on 830925,primary Meteorological Tower Air Temp Aspirator Failed,Rendering Differential Air Temp Sensing Instrument Inoperable for 48 H.Caused by Electrical Connector Short Due to Exposure to Environ | |
| 05000275/LER-1983-022-03, /03L-0:on 830831,valve MU-0-268 Shut for 36 Minutes,Isolating Raw Water Reservoir from Fire Suppression Header,Rendering Fire Suppression Water Sys Inoperable. Caused by Broken Underground Water Supply Line | /03L-0:on 830831,valve MU-0-268 Shut for 36 Minutes,Isolating Raw Water Reservoir from Fire Suppression Header,Rendering Fire Suppression Water Sys Inoperable. Caused by Broken Underground Water Supply Line | |
| 05000275/LER-1983-023-01, /01T-0:on 831012,util Informed by Pacific Scientific Co of Potential Problem W/Certain Serial Number PSA-1 & PSA-3 Snubbers.Insp Revealed Microcracks in Capstan Spring Tangs.Caused by Stress | /01T-0:on 831012,util Informed by Pacific Scientific Co of Potential Problem W/Certain Serial Number PSA-1 & PSA-3 Snubbers.Insp Revealed Microcracks in Capstan Spring Tangs.Caused by Stress | |
| 05000275/LER-1983-024-03, /03L-0:on 831007,all Main Control Room Annunciators Lost During Const Activity in Annunciator Cabinets.Caused by Const Worker Inadvertently Grounding Hot wire,short-circuiting Panel.Power Restored | /03L-0:on 831007,all Main Control Room Annunciators Lost During Const Activity in Annunciator Cabinets.Caused by Const Worker Inadvertently Grounding Hot wire,short-circuiting Panel.Power Restored | |
| 05000275/LER-1983-025-03, /03L-0:on 831021,steam Generator Blowdown Tank Vent Gross Activity Monitor RM-27 Failed Downscale While in svc.RM-27 Failed as Result of Random Failure of U-2 Bistable Multivibrator.Bistable Replaced | /03L-0:on 831021,steam Generator Blowdown Tank Vent Gross Activity Monitor RM-27 Failed Downscale While in svc.RM-27 Failed as Result of Random Failure of U-2 Bistable Multivibrator.Bistable Replaced | |
| 05000275/LER-1983-026-03, /03L-0:on 831114,prior to Fuel Load,Power Switch to Plant Vent Iodine Sampler RE-24 Found in Off Position. Caused by Personnel Error During Heavy Const Period. Protective Cover Will Be Placed Over Switch | /03L-0:on 831114,prior to Fuel Load,Power Switch to Plant Vent Iodine Sampler RE-24 Found in Off Position. Caused by Personnel Error During Heavy Const Period. Protective Cover Will Be Placed Over Switch | |
| 05000275/LER-1983-027-03, /03L-0:on 831117,diesel Generator 1-2 Air Receiver 1-2a Fell Below Min Pressure Setpoint.Caused by Starting Air Compressor 1-2A Internal Relief Valve Not Reseating.Relief Valve Replaced | /03L-0:on 831117,diesel Generator 1-2 Air Receiver 1-2a Fell Below Min Pressure Setpoint.Caused by Starting Air Compressor 1-2A Internal Relief Valve Not Reseating.Relief Valve Replaced | |
| 05000275/LER-1983-028-01, /01T-0:on 831130,air Gap Visible on Upper 25% of Containment Equipment Door.Review of Records Indicated Condition Existed During Initial Fuel Load.Procedure Change Made to Inspect Hatch & Add Bolts | /01T-0:on 831130,air Gap Visible on Upper 25% of Containment Equipment Door.Review of Records Indicated Condition Existed During Initial Fuel Load.Procedure Change Made to Inspect Hatch & Add Bolts | |
| 05000275/LER-1983-030-03, /03L-0:on 831116,discovered That Tech Spec Surveillance Requirement 4.3.3.3.1 for Channel Functional Test of Triaxial Time History Accelographs Not Performed. Caused by Personnel Error | /03L-0:on 831116,discovered That Tech Spec Surveillance Requirement 4.3.3.3.1 for Channel Functional Test of Triaxial Time History Accelographs Not Performed. Caused by Personnel Error | |
| 05000275/LER-1983-031-03, /03L-0:on 831122,discovered That Tech Spec 4.9.6.2 Re Load Testing of Auxiliary Hoist Performed Approx 240 H Prior to Use of Hoist,Contrary to 100 H Requirement.Caused by Misinterpretation of Tech Spec | /03L-0:on 831122,discovered That Tech Spec 4.9.6.2 Re Load Testing of Auxiliary Hoist Performed Approx 240 H Prior to Use of Hoist,Contrary to 100 H Requirement.Caused by Misinterpretation of Tech Spec | |
| 05000275/LER-1983-032-01, /01T-0:on 831205,fire Barrier Penetration Seal in RHR Pump 1-1 Room Discovered Nonfunctional.Maint Personnel Did Not Locate Fire Penetration Due to Insufficient Info on Work Request | /01T-0:on 831205,fire Barrier Penetration Seal in RHR Pump 1-1 Room Discovered Nonfunctional.Maint Personnel Did Not Locate Fire Penetration Due to Insufficient Info on Work Request | |
| 05000275/LER-1983-033-03, /03L-0:on 831202,source Range Instrumentation Channels Deenergized for 2 Minutes During Surveillance Test. Caused by I&C Technician Failing to Follow Written Procedure.I&C Personnel Instructed | /03L-0:on 831202,source Range Instrumentation Channels Deenergized for 2 Minutes During Surveillance Test. Caused by I&C Technician Failing to Follow Written Procedure.I&C Personnel Instructed | |
| 05000275/LER-1983-035-03, /03L-0:on 831201,fire Suppression Spray & Sprinkler Sys & Cardox Sys Valve Positions Not Verified. Caused by Personnel Overlooking Addl Data Sheets Provided by Procedure Amend.Personnel Instructed | /03L-0:on 831201,fire Suppression Spray & Sprinkler Sys & Cardox Sys Valve Positions Not Verified. Caused by Personnel Overlooking Addl Data Sheets Provided by Procedure Amend.Personnel Instructed | |
| 05000275/LER-1983-036-03, /03L-0:on 831211,one Train of Control Room Ventilation Sys Inoperable for 31 Minutes.Caused by Thermal Overload Trip of Fan S-36.Fan Reset.Investigation Revealed Need to Rewind Fan Motor | /03L-0:on 831211,one Train of Control Room Ventilation Sys Inoperable for 31 Minutes.Caused by Thermal Overload Trip of Fan S-36.Fan Reset.Investigation Revealed Need to Rewind Fan Motor | |