05000269/FIN-2010009-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Adequately Monitor Performance of the Standby Shutdown Facility HVAC System as Required by 10 CFR 50.65 |
Description | An NRC-identified non-cited violation of 10 CFR 50.65(a)(2), was identified for failure to demonstrate that Standby Shutdown Facility (SSF) Ventilation system performance was being effectively controlled through the preventive maintenance (PM) program, or place the system in 10 CFR 50.65(a)(1) status due to SSF Heating Ventilation and Air Conditioning (HVAC) system maintenance rule functional failures beyond established performance criteria. The failure to perform adequate performance or condition monitoring on the SSF HVAC system was a performance deficiency (PD). This PD was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective in that the licensee failed to demonstrate effective control of the SSF HVAC system through appropriate preventive maintenance. The finding was determined to have very low safety significance (Green) because it did not result in the actual loss of safety function of one or more non-Technical Specification equipment trains, designated as risk-significant per 10CFR50.65, for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The cause of the finding was directly related to the human performance crosscutting aspect associated with resources, for the licensee not ensuring their maintenance rule procedures were adequate to provide clear and accurate directions on how to classify functional failures. |
Site: | Oconee ![]() |
---|---|
Report | IR 05000269/2010009 Section 4OA4 |
Date counted | Dec 31, 2010 (2010Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 95002 |
Inspectors (proximate) | J Bartley A Barker T Hoeg L Suggs T Lighty |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |
Finding - Oconee - IR 05000269/2010009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Oconee) @ 2010Q4
Self-Identified List (Oconee)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||