05000266/FIN-2014004-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Identify Degraded Water Sprinkler System |
| Description | The inspectors identified a finding of very low safety significance and associated NCV of license condition 4.F for the licensees failure to identify a degraded water sprinkler system in the service water pump room and implement hourly fire watch inspections. Specifically, the licensee installed scaffolding in the service water pump room that interfered with the operation of the water sprinkler system and failed to implement hourly fire watch inspections as a compensatory measure. The licensee began fire watch inspections and credited installed fire hoses in the area for backup suppression until the planking could be removed from the scaffolding. The finding was determined to be more than minor because the failure to identify the degraded sprinkler system and implement compensatory fire watch inspections was associated with the Mitigating Systems cornerstone attribute of Protection Against External Events (Fire) and affected the cornerstone objective of preventing undesirable consequences (i.e., core damage). In accordance with IMC 0609, Significance Determination Process, Attachment 0609.04, Initial Characterization of Findings, Table 2, the inspectors determined the finding affected the Mitigating Systems cornerstone. The finding degraded fire protection defense-in-depth strategies, and the inspectors determined, using Table 3, that it could be evaluated using Appendix F, Fire Protection Significance Determination Process. The inspectors screened the issue to Green under the Phase 1 Screening Question 1.3.1A, because the inspectors determined that the impact of a fire would be limited to one train/division of service water pumps and a credited safe shutdown path would be unaffected. This finding has a cross-cutting aspect of Procedure Adherence (H.8), in the area of human performance, because the licensee did not follow processes, procedures, and work instructions. |
| Site: | Point Beach |
|---|---|
| Report | IR 05000266/2014004 Section 1R05 |
| Date counted | Sep 30, 2014 (2014Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | D Oliver J Beavers J Cameron J Rutkowski K Barclay M Learn R Edwards R Morris V Myers |
| Violation of: | License Condition - Fire Protection License Condition |
| CCA | H.8, Procedure Adherence |
| INPO aspect | WP.4 |
| ' | |