Finding | |
|---|---|
| Title | Failure to Identify Significant Steam Leak on the Unit 2 HPCI Turbine STeam Admission Valve |
| Description | A self-revealing Apparent Violation (AV) of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Actions, was identified for the licensees failure to take corrective following the discovery of a significant steam leak from the packing gland of the Unit 2 HPCI steam inlet isolation valve, 2-FCV-73-16. Specifically, the licensee failed to correctly classify the severity of the leak on 2-FCV-73-16 as described in NPG-SPP-06.8, Leak Reduction Program, and allowed the condition to degrade until packing failure. Upon discovery of the packing failure, the licensee took action to isolate the associated steam leak and declare the HPCI system inoperable. Repairs were completed and tested on September 19, 2015. The licensee entered the issue into their corrective action program as CR 1082405 The performance deficiency was determined to be more-than-minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and it adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e. core damage). Specifically, misclassification of the leak severity as minor led to the loss of function of the HPCI system when valve 2-FCV-73-16 packing degraded until packing failure. The finding could not be screened to Green and is pending a significance determination. The inspectors determined that the finding had a cross cutting aspect of Resolution because the licensee did not take timely corrective action to repair the Unit 2 HPCI steam leak before it lead to a Safety System Functional Failure. (P.3) |
| Site: | Browns Ferry |
|---|---|
| Report | IR 05000260/2015004 Section 4OA3 |
| Date counted | Dec 31, 2015 (2015Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | A Blamey A Nielsen A Ruh C Fontana D Dumbacher R Kellner R Powell R Williams S Sanchez T Stephena Ruhd Dumbacher D Roberts R Baldwin T Stephen |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |