05000254/LER-2014-003, Regarding HPCI Interlock Doors Opened Simultaneously Cause Loss of Secondary Containment
| ML14212A499 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities (DPR-029, DPR-030) |
| Issue date: | 07/17/2014 |
| From: | Darin S Exelon Generation Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| SVP-14-054 LER 14-003-00 | |
| Download: ML14212A499 (6) | |
| Event date: | |
|---|---|
| Report date: | |
| Reporting criterion: | 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(ix)(A) 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 2542014003R00 - NRC Website | |
text
uy 17, 2014 10 CFR 60.73 SVP-14-054 U. S. Nuler Asguaomy Commimss*on ATTN: Doctuent Control Desk Waslgon. D.C.
o0566 Quad Cii Nudcr Powr S*Io, Unl m Ied 2 Renewed Faclity Oereftn Licens No. OPR-29 and 30 Subect Lic e evt Repo 2,4/,040.0, IHPCI kteock Door Opened S
yaufwlWo Caum Los of Seconfdy CooimmWe Enclox*
Is Lcs Ev" Repot (LER) 254=14-000M o4PCI InUlck Door Opened Slm aneoul* y Cause Lose of Seconday Containmet,' for Quad Cities Nuclear Power Station, UniL 1.
This r t is s*ybntd in accomnrdce with 10 CFR 50.73 (aX2Xv)(C) i reqwire the mpxo of any event or concdi that could he prevented the fulfilent of th safely kfuin of stlues or sysms tat are neede to: control the rlease of mr tive material.
Ther are no regulatory cmmtm s ontaned in t istr.
Should you have Wy questions coni Ofth epon, pla onta W. W. J. Beck at (309) 227-2900.
Dafn Site Vime Presieden Quad Cities Nuclear Power StMion cc:
Regional Adm i "itaor
- - NRC Region 0I NRC Senior Resident Insplecor - Quad Mes Nuclear Power Station
NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 01/31/2017 (02-2014)
Estimated burden per response to comply with this mandatory collection request: 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.
W (Reported lessons learned are incorporated into the licensing process and fed back to industry.
Send comments regarding burden estimate to the FOIA, Privacy and Information Collections Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by LICENSEE EVENT REPORT (LER) internet e-mail to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and (See Page 2 for required number of Regulatory Affairm, NEOB-1 0202, (3150-0104), Office of Management and Budget, Washington, DC 20503. It a means used to impose an information collection does not display a currently valid OMB digits/characters for each block) control number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.
- 3. PAGE Quad Cities Nuclear Power Station Unit 1 05000254 1 OF 5
- 4. TITLE HPCI Interlock Doors Opened Simultaneously Cause Loss of Secondary Containment
- 5. EVENT DATE
- 6. LER NUMBER
- 7. REPORT DATE
- 8. OTHER FACILITIES INVOLVED FACILTY NAME DOCKET NUMBER MO YEAR YEAR NUMBER NO.
NTH DAY YEAR Quad Cities Nuclear Power Station Unit 2 A0 2
FACILITY NAME DOCKET NUMBER 0 14 o04 -
003 00 07 17 2014 N/A N/A
- 9. OPERATING MODE
- 11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)
E] 20.2201(b)
El 20.2203(a)(3)(i)
EI 50.73(a)(2)(i)(C)
El 50.73(a)(2)(vii)
[]
20.2201(d)
[
20.2203(a)(3)(ii) 50.73(a)(2)(ii)(A)
[] 50.73(a)(2)(viii)(A)
E] 20.2203(a)(1) 20.2203(a)(4) 50.73(a)(2)(ii)(B)
El 50.73(a)(2)(viii)(B)
El 20.2203(a)(2)(i)
El 50.36(c)(1)(i)(A)
El 50.73(a)(2)(iii)
El 50.73(a)(2)(ix)(A)
- 10. POWER LEVEL El 20.2203(a)(2)(ii)
El 50.36(c)(1)(ii)(A)
El 50.73(a)(2)(iv)(A)
El 50.73(a)(2)(x)
El 20.2203(a)(2)(iii)
El 50.36(c)(2)
El 50.73(a)(2)(v)(A)
El 73.71(a)(4)
El 20.2203(a)(2)(iv)
El 50.46(a)(3)(ii)
El 50.73(a)(2)(v)(B)
El 73.71(a)(5) 100 20.2203(a)(2)(v)
El 50.73(a)(2)(i)(A) 50.73(a)(2)(v)(C)
El OTHER Specify in Abstract below or in El 20.2203(a)(2)(vi)
El 50.73(a)(2)(i)(B)
El 50.73(a)(2)(v)(D)
PLANT AND SYSTEM IDENTIFICATION
General Electric - Boiling Water Reactor, 2957 Megawatts Thermal Rated Core Power,~
Energy Industry Identification System (EIIS) codes are identified in the text as [XX].
EVENT IDENTIFICATION Both doors in the secondary containment interlock between the Unit 1 High Pressure Coolant Injection room and the adjoining tunnel in the Turbine Building were opened simultaneously and caused a loss of secondary containment.
A.
CONDITION PRIOR TO EVENT
Unit: 1 / 2 1
Event Date: May 22, 2014 Reactor Mode: 1 / 1 Mode Name: Power Operation / Power Operation Event Time: 2150 hours0.0249 days <br />0.597 hours <br />0.00355 weeks <br />8.18075e-4 months <br /> Power Level: 100% / 100%
B.
DESCRIPTION OF EVENT
On May 22, 2014, at 2150, Mechanical Maintenance notified the main control room (MCR) that both Unit 1 High Pressure Coolant Injection (HPCI),secondary containment interlock doors were open at the same time. The failure of this interlock caused a loss of secondary containment per Technical Specification (TS) 3.6.4.1, Condition A. The doors were immediately reclosed, and the secondary containment boundary was reestablished. Operators verified the Reactor Building (secondary containment) differential pressure was maintained operable at greater than 0.10 inch of vacuum water gauge.
The Operations Field Supervisor was then dispatched to the HPCI tunnel to investigate the condition.
It was determined that the condition could be recreated. Operators staged signage and ropes to administratively control the interlock closed until repairs could be performed.
Secondary containment remained available and functional during the event since the secondary containment interlock was immediately restored and the RB differential pressure was maintained during the event. A review of the Station Event Recorder (SER) verified that RB low differential pressure alarms were not received during this event. The RB is a common volume to both Units 1 and 2, and an interlock failure can impact the secondary containment for both units.
On May 23, 2014, at 0101 hours0.00117 days <br />0.0281 hours <br />1.669974e-4 weeks <br />3.84305e-5 months <br />, ENS#50132 was made to the NRC under 10 CFR 50.72(b)(3)(v)(C), to report this event as an event or condition that could have prevented the fulfillment of a safety function.
Prior to the event on May 22, mechanics were transferring scaffold material through the interlocks on carts from the HPCI room into the tunnel. Two mechanics had opened the door to the Unit 1.HPCI room to transport a cart of scaffold material tothe tunnel. While this door was open, a third mechanic inside the HPCI tunnel proceeded to open the tunnel-side door. He stated that he looked at the indicator light near the door and that it appeared to be off before he opened the door. Upon seeing the HPCI room door open, the-third mechanic closed the tunnel door immediately to reestablish secondary containment.
Following notification of the MCR, the Operations Field Supervisor investigated the doors. It was identified that the indicator light inside of the HPCI tunnel was very dim and is barely noticeable without very close examination. In addition, the light is very small and located near a bright ceiling light, adding to the visibility issues.
It was also identified that the plungers for the TB-side door would not engage fully to keep the door from opening while the interlock was energized. The locking bolt that secures the passive door into the floor was bent such that the doors were not closed completely tight against the threshold. The result was that the plungers did not align with the slot in the door to lock the door closed.
On May 23, 2014, the TB passive door locking bolt was replaced and the doors were properly aligned with the plungers. The interlock then functioned normally.
Given the impact on the secondary containment, this report is submitted (for Units 1 and 2) in accordance with the requirements of 10 CFR 50.73 (a)(2)(v)(C), Which requires the reporting of any event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to control the release of radioactive material.
C.
CAUSE OF EVENT
The apparent cause of the event on May 22, 2014, was the bent locking bolt onthe passive TB-side door. Since the bolt was not effectively holding the passive door, and subsequently the active door, the doors were not closed tightly to the threshold. Also, the plungers were not aligned with the slots on the door. Since the plungers were not aligned, they did not lock into the slots when the logic was activated by the other door. Without the plungers locking the doors closed, the mechanic was able to open the door.
The contributing cause of the event was the degraded indication light in the HPCI tunnel. Had the indication been clearly visible, the mechanic would have known the other door was open and would not have challenged the door.
D.
SAFETY ANALYSIS
System Design
The function of the secondary containment is to contain, dilute, and hold up fission products that may leak from primary containment following a Design Basis Accident (DBA). In conjunction with operation of the Standby Gas Treatment System (SBGTS) [BH] and closure of certain valves [V] whose lines penetrate the secondary containment, the secondary containment is designed to reduce the activity level of the fission products prior to release to the environment, and to isolate and contain fission products that are released during certain operations that take place inside primary containment, when primary containment is not required to be operable, or that take place outside primary containment.
Updated Final Safety Analysis Report (UFSAR) Section 6.2.3.1 provides that the safety objective of the secondary containment system, in conjunction with other engineered safeguards a'hdznuclear safety systems,.is to limit the release of radioactive materials so that offsite doses resulting from a postulated DBA will remain below 10 CFR 100 guideline values.
The secondary containment interlocks are designed to provide personnel access to the RB from the TB while maintaining a negative differential pressure in the RB. The Unit 1 HPCI -interlock doors are normally secured closed by mechanical latches. Each door is operated manually with a door knob,' and interlock logic. is activated to actuate plungers that lock closed the oppositebdoor in the interlock. The doors are designed with relay logic so that only one door can be opened at a time. A red light near each door illuminates when one of the doors is open.
Safety Impact Both Units 1 and 2 share a common RB (secondary containment). When both HPCI interlock doors were opened simultaneously, this caused a momentary loss of secondary containment.
TS 3.6.4.1, Condition A, requires restoration of secondary containment to operable status within four hours. This four hour Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining secondary containment during Modes 1, 2, and 3, since the probability of an accident occurring during this short period is minimal.-
The primary purpose of the secondary containment is to minimize the ground level release of airborne radioactive materials and to provide a controlled, elevated release of the building atmosphere under accident conditions. An engineering analysis was performed to demonstrate that during the short (momentary) time that both doors of the corresponding interlock were simultaneously opened, the doors were not open sufficiently long enough to cause a RB low differential pressure alarm, hence no loss of secondary containment differential pressure occurred. Secondary containment would have sufficiently contained radioactive materials during a LOCA such that all current dose limits would remain to be met. As a result, the system safety function of secondary containment would have been maintained throughout the event. Therefore, the dose consequence from postulated releases from the RB during this short duration would remain to be bounded by the existing design basis LOCA dose analysis. The safety significance of this event was minimal.
The engineering analysis that was performed demonstrated this event did not constitute a Safety System Functional Failure (SSFF). (Reference NEI 99-02, Revision 7, Regulatory Assessment Performance Indicator Guideline, Section 2.2, Mitigating Systems Cornerstone, Safety System Functional Failures, Clarifying Notes, Engineering analyses.) As such, this event will not be reported in the NRC Performance Indicator (PI) for safety system functional failures since an engineering analysis was performed which determined that the system was capable of performing its safety function during this event when both doors of the secondary containment interlock were momentarily simultaneously opened.
Risk Insights The plant Probabilistic Risk Assessment (PRA) model gives no credit to the secondary containment and does not include it in the model. Therefore, the as-found conditions did not contribute to an increase in risk. In addition, the physical integrity of the secondary containment structure was never compromised and the primary containment function was never lost.
Although secondary containment was momentarily inoperable per TS 3.6.4.1, Condition A, when the Unit 1 HPCI interlock doors were opened simultaneously due to a malfunction, there was no Design Based Accident condition in progress, and secondary containment function was restored immediately when one of the doors was closed.
RB differential pressure was maintained during the event.
In conclusion, the overall safety significance and impact on risk of this event were minimai.
E.
CORRECTIVE ACTIONS
Immediate:
- 1. Operators staged signage and ropes to administratively control access through the HPCI interlock until repairs could be performed.
- 2.
Replaced the bent locking bolt on the TB passive door with a new bolt, and realigned the doors.
Follow-up:
- 1.
Add steps to the preventive maintenance procedure to inspect door hardware annually.
- 2. Upgrade the door indication lights to LEDs to improve reliability and visibility.
F.
PREVIOUS OCCURRENCES
The station events database, LERs, and INPO Consolidated Event System (ICES)were reviewed for similar events at Quad Cities Nuclear Power Station. This event was a failure of a secondary containment interlock door bolt which caused two interlock doors to be open simultaneously. Based on the conditions of this event, causes, and associated corrective actions, the events listed below, although similar in topic, are not considered significant station experiences that would have directly contributed to preventing this event.
Station Issue Report (IR) 1345004, Reactor Building Interlock Door Opened with Other Door Open (3/23/12) - The RB and TB doors in the Unit 2 RFP interlock had been opened simultaneously. Later when the doors were inspected, the magnets and logic were found to be functioning normally.. It was suspected that the RB door actuator had overheated from excessive use the previous day resulting in the malfunction. The condition could not be replicated, so the true cause could not be identified. The current LER did not identify a failed actuator as the cause. Therefore, this past interlock failure event is not directly applicable to the event of the current LER.
LER 254/2012-004-00, 11/05/12, Breach in Secondary Containment (09/06/12) - Two doors in the Unit 2 RFP interlock had been opened simultaneously. The HRSS-side door opened unexpectedly while the RB-side door was open due to a malfunctioning door latch. The HRSS door was immediately shut. The apparent cause was
- - the HRSS-side door latching mechanism was not fully engaged while coupled with its crash bar may have been bumped. Since the HRSS door has a different style of latch than.the interlock doors of-the current LER, this previous event is not directly applicable to the current LER.
Station Issue Report (IR) 1641747, Both U2 RB 595 RFP to RB Interlock Doors Open Simultaneously (4/1/14) -
Both doors in the secondary containment interlock on the 595 foot elevation from the Unit 2 Reactor Feed Pump (RFP) room to the Reactor Building (RB) were open simultaneously. The doors were immediately closed and secondary containment was reestablished. The cause of the secondary containment event was due to a failed interlock door actuator that caused both doors to open simultaneously. The design of this interlock is different from the HPCI interlock. Therefore, this previous interlock actuator failure is not directly applicable to the cUrrent LER.
G.
COMPONENT FAILURE DATA
Failed Equipment: Locking Bolt Component Manufacturer: N/A Component Model Number: N/A Component Part Number: N/A This event has been reported to ICES as Failure Report No. 312012.