Finding | |
|---|---|
| Title | Inadequate Corrective Actions Following Identification of a NON-CONSERVATIVE Technical Specification |
| Description | An NRC identified non-cited violation of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, was identified when the licensees failure to take timely corrective action to address a nonconforming condition of Technical Specification (TS) 3/4.5.2 S R4.5.2a. The non-conservative TS was identified and placed in the corrective action program in 2006 as CR 2006-22868. TS 3.5.2 SR 4.5.2a was determined to be non-conservative and the corrective action to submit a TS amendment to address the non-conservative TS was not implemented. The licensee is scheduled to submit the license amendment in the fourth quarter of 2012, as referenced in AR 1790829. The inspectors determined that the licensees failure to timely correct a condition adverse to quality associated with the non-conservative TS was a performance deficiency. The performance deficiency was more than minor because if left uncorrected the failure to implement timely corrective actions has the potential to lead to a more significant safety event in that the unit could be placed in an unanalyzed condition for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The inspectors determined that the finding was of very low safety significance because there has been no loss of safety system function. The inspectors determined that this finding directly involved the crosscutting area of Problem Identification and Resolution, component of the CAP and an aspect in taking appropriate corrective actions to address safety issues in a timely manner, commensurate with their safety significance and complexity. |
| Site: | Turkey Point |
|---|---|
| Report | IR 05000250/2012011 Section 4OA2 |
| Date counted | Sep 30, 2012 (2012Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | G Hopper R Taylor R Reyes M Barillas T Lighty S Mendez-Gonzalez N Coovert |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Turkey Point - IR 05000250/2012011 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Turkey Point) @ 2012Q3
Self-Identified List (Turkey Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||