05000247/LER-1982-005, Forwards LER 82-005/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 82-005/03L-0
ML20042A237
Person / Time
Site: Indian Point 
Issue date: 03/08/1982
From: Otoole J
CONSOLIDATED EDISON CO. OF NEW YORK, INC.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20042A238 List:
References
NUDOCS 8203230235
Download: ML20042A237 (1)


LER-1982-005, Forwards LER 82-005/03L-0
Event date:
Report date:
2471982005R00 - NRC Website

text

N John D. O'Toob

' Vice Pres 4ent Consolidatec 2dison Company of New York. Inc 4 Irving Place. New York, NY 10003 Telephone (212) 460-2533 March 8, 1982 Re: Indian Point Unit No. 2 Docket No. 50-247 IER-82-005/03L-0 S LY2 /

Mr. Ronald C. Haynes, Regional Administrator

/M Office of Inspection and Enforccment

, }/

q Region I J/

,,s U. S. Nuclear Regulatory Ccmnission

.c]

d 2 lS3g.

631 Park Avenue h_l T / : n 7 '2

- j>

King of Prussia, Pa.

19406

~ ;..u :;~

L 8

Dear Mr. Haynes:

f

'Ihe attached Licensee Event Report LER-82-005/03L-0 is hereby sutmitted in accordance with the requirements of Technical Specification 6.9.1.7.

This event is of the type described in _

Technical Specification 6.9.1.7.2.b.

Three copies of this letter and the attachment are enclosed as required.

truly yours,,

V ll/j.y, L 'llt' attach.

cc:

Mr. Richard DeYoung, Director (30 copies) l Office of Inspection and Enforcenent c/o Distribution Services Branch, DDC, AD1 I

U. S. Nuclear Regulatory Comnission l

Washington, D. C.

20555 Mr. William G. Mcdonald, Director (3 copies)

Office of Managanent Information and Program Control c/o Distribution Services Branch, DDC, ADM l

U. S. Nuclear Regulatory Cmmission Washington, D. C. 20555 Mr. T. Rebelowski, Senior Resident Inspector U. S. Nuclear Regulatory Cm mission P. O. Box 38 Buchanan, New York 10511 l

8203230235 820308 PDR ADOCK 05000247 S

PDR II eP T

.g