Title | Licensee-Identified Violation |
Description | Violation: Technical Specifications (TS) Limiting Condition of Operability (LCO) 3.3.1, Reactor Trip System (RTS) Instrumentation, required the RTS instrumentation for each Function in Table 3.3.1-1 to be operable. The over temperature delta-T (T) function listed in Table 3.3.1-1 required 3 channels to be operable in Modes 1 and 2. With one channel inoperable, the required actions of Condition E of LCO 3.3.1 are required to be performed within the completion time. LCO 3.0.3 required in part, when an LCO is not met and the associated actions are not met, an associated action is not provided, or if directed by the associated actions, the unit shall be placed in a mode or other specified condition in which the LCO is not applicable. Action shall be initiated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to place the unit, as applicable, in: Mode 3 within 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />; Mode 4 within 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br />; and Mode 5 within 37 hours4.282407e-4 days <br />0.0103 hours <br />6.117725e-5 weeks <br />1.40785e-5 months <br />.
Contrary to the above, since Unit 2 entered Mode 2 on Nov. 12, 2017, at 1138 with two channels of the OT delta T function inoperable until Nov. 13, 2017, at 0115 when one channel of the T function was restored, the licensee failed to place Unit 2 in Mode 3 within 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> and then Mode 4 within 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> as required by LCO 3.0.3. The time the two channels of the OTdelta T function was inoperable totaled 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> and 37 minutes. LCO 3.3.1 does not provide an associated action with two channels of the OT delta T function inoperable in Modes 1 and 2. The OT delta T trip function is provided to ensure that the design limit departure from nucleate boiling ratio (DNBR) is met. The inputs to the OT deltaT trip include pressure, coolant temperature, axial power distribution and reactor power as indicated by loop delta temperatures at full reactor coolant flow. Power range channel NI-42 provided the channel 2 input and pressurizer pressure instrument PT-457 provided the channel 3 input into the OT deltaT function. PT-457 was declared inoperable on Nov. 11, 2017, at 0522 and NI-42 was declared inoperable on Nov. 13, 2017, at 0136. Because NI-42 was found with a degraded center pin on high voltage cable connector, it was determined to be inoperable since Nov. 10, 2017. As a result, Unit 2 entered Mode 2 with two inoperable channels of OT delta T which is contrary to TS requirements. |
Site: | Farley |
---|---|
Report | IR 05000348/2018002 Section 4OA3 |
Date counted | Jun 30, 2018 (2018Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | P Niebaum K Miller R Carrion A Nielsen W Pursley J Rivera D Mas-Penaranda A Blamey |
Violation of: | Technical Specification |