05000331/FIN-2014005-05
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Inadequate Containment Isolation Valve Leak Tightness Test Procedure |
Description | The inspectors identified a finding of very low safety significance and an associated non-cited violation of Title 10 of the Code of Federal Regulation, Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to establish an adequate procedure for an activity affecting quality for a system penetrating the primary containment pressure boundary. Specifically, Surveillance Test Procedure STP 3.6.1.1-09, Containment Isolation Valve Leak Tightness Test Type C Penetrations TIP [traversing in-core probe] Valves, Revision 4, failed to include leak rate testing instructions for all of the fittings inboard of the outboard TIP valves tested, which constituted part of the primary containment pressure boundary. The licensee entered the issue in their Corrective Action Program as condition report 02003580. As part of their corrective actions, the licensee re-performed a local leakage rate test to verify the fittings were leak tight. The inspectors determined that the finding was more than minor because it was associated with the Barrier Integrity cornerstone attribute of procedure quality and adversely affected the cornerstone objective to provide reasonable assurance that physical design barriers (fuel cladding, reactor coolant system, and containment) protect the public from radionuclide releases caused by accidents or events. As it related to the finding, procedure STP 3.6.1.1-09 lacked adequate instructions to ensure no leakage of a system penetrating the primary containment pressure boundary. The finding was of very low safety significance (Green) because it did not represent an actual open pathway of reactor containment and did not involve an actual reduction in function of hydrogen igniters in the reactor containment. The finding was associated with the cross-cutting aspect of resources in the area of Human Performance because STP 3.6.1.1-09 did not include testing of the fittings inboard of the outboard TIP valve as required. [H.1] |
Site: | Duane Arnold |
---|---|
Report | IR 05000331/2014005 Section 1R22 |
Date counted | Dec 31, 2014 (2014Q4) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.22 |
Inspectors (proximate) | A Boland A Dahbur C Phillips G O'Dwyer J Beavers J Gilliam J Heath J Jacobson J Steffes L Haeg M Jeffers M Jimenez M Phalen N Feliz-Adorno R Murray R Ng S Smith T Bilik V Meyers |
Violation of: | 10 CFR 50 Appendix B Criterion V |
CCA | H.1, Resources |
INPO aspect | LA.1 |
' | |
Finding - Duane Arnold - IR 05000331/2014005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Duane Arnold) @ 2014Q4
Self-Identified List (Duane Arnold)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||