Pages that link to "05000328/LER-1982-081, Forwards LER 82-081/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000328/LER-1982-081, Forwards LER 82-081/03L-0:
Displayed 50 items.
- 05000327/LER-1982-079, Forwards LER 82-079/03L-0 (← links)
- 05000327/LER-1982-075, Forwards LER 82-075/03L-0 (← links)
- 05000327/LER-1982-071, Forwards LER 82-071/03L-0 (← links)
- 05000327/LER-1982-074, Forwards LER 82-074/03L-0 (← links)
- 05000327/LER-1982-078, Forwards LER 82-078/03L-0 (← links)
- 05000327/LER-1982-076, Forwards LER 82-076/03L-0 (← links)
- 05000328/LER-1982-077, Forwards LER 82-077/03L-0 (← links)
- 05000327/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000327/LER-1982-072, Forwards LER 82-072/03L-0 (← links)
- 05000328/LER-1982-073, Forwards LER 82-073/03L-0 (← links)
- 05000327/LER-1982-067, Forwards LER 82-067/03L-0 (← links)
- 05000328/LER-1982-064, Forwards LER 82-064/03L-0 (← links)
- 05000328/LER-1982-063, Forwards LER 82-063/03L-0 (← links)
- 05000327/LER-1982-059, Forwards LER 82-059/03L-0 (← links)
- 05000328/LER-1982-061, Forwards LER 82-061/03L-0 (← links)
- 05000328/LER-1982-062, Forwards LER 82-062/03L-0 (← links)
- 05000328/LER-1982-060, Forwards LER 82-060/03L-0 (← links)
- 05000328/LER-1982-057, Forwards LER 82-057/03L-0 (← links)
- 05000327/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000327/LER-1982-036, Forwards LER 82-036/03L-0 (← links)
- 05000328/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000328/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000327/LER-1982-056, Forwards LER 82-056/03L-0 (← links)
- 05000328/LER-1982-058, Forwards LER 82-058/03L-0 (← links)
- 05000327/LER-1982-054, Forwards LER 82-054/03L-0 (← links)
- 05000327/LER-1982-086, Forwards LER 82-086/03L-0 (← links)
- 05000327/LER-1982-092, Forwards LER 82-092/03L-0 (← links)
- 05000327/LER-1982-126, Forwards LER 82-126/01T-0 (← links)
- 05000327/LER-1982-144, Forwards LER 82-144/03L-0 (← links)
- 05000328/LER-1982-142, Forwards LER 82-142/03L-0 (← links)
- 05000327/LER-1982-135, Forwards Updated LER 82-135/03X-1 (← links)
- 05000328/LER-1982-137, Forwards Updated LER 82-137/03X-1 (← links)
- 05000328/LER-1982-083, Forwards LER 82-083/03L-0 (← links)
- ML20071K654 (redirect page) (← links)
- 05000328/LER-1982-081 (redirect page) (← links)
- 05000327/LER-1982-080, Forwards LER 82-080/01T-0 (← links)
- 05000328/LER-1982-081-03, /03L-0:on 820625,automatic Control Valve 1-PCV-3-122 Failed to Open on Demand Twice.First Event Caused by Low Oil in Hydraulic Reservoir Due to Leaking Fitting.Second Event Caused by Foreign Matl in Oil (← links)
- 05000328/LER-1982-138-03, /03L-0:on 821123,lower Containment Airlock Door Failed Air Leak Rate Test.Caused by Backed Off Packing Nut That Allowed Packing to Loosen.Nut Retightened & Door Tested.Design Change Request Submitted (← links)
- 05000327/LER-1982-131-03, /03L-0:on 821109,during Mode 6,nuclear Instrumentation Sys Source Range Detector N-32 Declared Inoperable Due to Spiking.Caused by Heat Gun Used in Work on Penetration Junction Boxes.Penetration Work Suspended (← links)
- 05000328/LER-1982-132-03, /03L-0:on 821103,one RHR Pump Declared Inoperable Due to Discharge Flow Switch Failure to Actuate.Caused by Failure of Contacts to Close Due to Faulty Actuating Cam. Flow Switch Repaired & Recalibr (← links)
- 05000328/LER-1982-129-03, /03L-0:on 821103,letdown Orifice Containment Isolation Valve 2-FCV-62-73 Failed Shut.Caused by Control Fuses Failing Due to Shorted Coil in Relay 8149AX.Coil & Fuses Replaced.Valve Tested & Returned to Svc on 821104 (← links)
- 05000327/LER-1982-117-03, /03L-0:on 820914,during SI-220 Test on Fire Pump 1B-B Start Circuit,Time Delay Setpoint on Relay 1B2 Found Out of 5% Tolerance of 120-s.Cause Not Stated.Time Delay Setpoint Readjusted to within 5% Tolerance (← links)
- 05000327/LER-1982-012-03, /03L-0:on 820122,when Divider Barrier Equipment Hatch 3 Was Opened,Seal Gasket Discovered Missing.Probably Caused by Personnel Failure to Verify Gasket Reinstallation on 811016.Gasket Installed.Engineers Reinstructed (← links)
- 05000328/LER-1982-136-03, /03L-0:on 821115,inleakage Found to Be 340 Cubic Ft Per Minute to Annulus During Performance of Surveillance Instruction 264.Caused by Numerous Leaks Found Through Personnel Access & Equipment Doors & Other Areas (← links)
- 05000327/LER-1982-128-01, /01T-0:on 821109,discovered That Suction Damper FCO-31A-14 Had Not Closed Allowing Direct Flow Path to Outside Environ.Caused by Faulty Air Operated Solenoid Valve.Damper Repaired & Operation Verified (← links)
- 05000327/LER-1982-124-03, /03L-0:on 821023 & 28,liquid Radwaste Effluent Line Monitor Failed to Meet Surveillance Requirement.Caused by Contamination Buildup in Sample Chamber.Sample Chamber Cleaned.Procedures Under Review (← links)
- 05000328/LER-1982-122-03, /03L-0:on 821021,during Mode 1 Operation, Pressurizer Pressure Channel 2-PS-68-323B Declared Defective Due to Loss of Ac Power to Channel.Caused by Defective Fuse Holder Cap.Cap Replaced & Channel Returned to Svc (← links)
- 05000327/LER-1982-116-03, /03L-0:on 820916,both Trains of RHR Sys Inoperable Due to Inadvertent Closing of RHR Suction Valve 1-FCV-74-2. Caused by Removal of Power Fuses to Allow Work on Output Relays.Rhr Pump Stopped & Valve Reopened W/Auxiliary Pow (← links)
- 05000328/LER-1982-115-01, /01T-0:on 821002,inner & Outer Doors of Upper Containment Personnel Airlock Were Open Simultaneously Due to Latch Bar Blocking Outer Door Open.Caused by Door Swing Operating Chain Being Out of Adjustment.Chain Adjusted (← links)
- 05000327/LER-1982-112-03, /03L-0:on 820911,upper Head Injection Sys Declared Inoperable Due to Failure to Meet Surveillance Requirements. Caused by Total Dissolved Nitrogen & Air in Accumulator Exceeding 80 Std Cubic Feet Limit (← links)