Davis-Besse Nuclear Power Station, Unit 1, Revision 31 to Updated Final Safety Analysis Report, Drawing E-0060B, Rev 1, Sheet 4D
ML17045A346
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 11/21/2016
From:
Bechtel Company, FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17039A594 List: ... further results
References
L-16-322 E-0060B, Rev 1
Download: ML17045A346 (1)


Text

(Page 2 of 2) NElllFAX 3/85 1151313 MCC Et2A 480 31 60HZ l--+---f--+--t--11 a:: 0 ..., -..... j + &.(') O"l I aJ i ... 1111 ,,.

  • a ..... C-+-.....,._t---_ t t t . 261§ 1 .a. . }--)--)s2 s20 2.s 21I .e. A
  • 480-t20V 2.5 XI A OL .E ..... f *. .-*. P' ' ' ** -... -... .. .. ....... -::-. ... . .. . -........ -. .* t -*. fi .. . . . ...... * '* -... .. -.-,, -* .. ,._ -** **---... " ' -. . . * -. *.. :.,. *-: .. :*-. < . *.
  • _. .**< .* _ *' . .. -.. .*_ ... *_ .. _-.. -..... *:.**--. .:"" .-.* -**-: . *.. *-**: R G >-CD ' G / 0 c.o i.n I ,._ L&J -I z co <..> 0 c c.o I
  • L&J u. L&J :z a:: (._) TR 13 RC WO <NOTE 31 l.!: 0 .. I '11111" .
  • LL. ;; > LL.I w a:: & a:: Tl T2 T3 .. c::::> c::::> 0 0 I I &.(') &.(') ,.,., ,...., ..,., ..,., 0 0 * * ,..,., ,..,., 0 0 a:: 0: <...> u L&J w 0: a:: 0 0 u. LL. L&J I-=-<CC Cl c a.. 0.. :::::> =:I . . :z z L&J L&J SCHEME MCC NO. (!) t!) BE1217 E12A -0 i j ,. SU CHANNEL NO. NO. 30 I CL 5 .a N 13 1! 42b . 42 cc SCHEME BE1217 EQUIPMENT B F M . NC071 l BE1217 FTS5318 MC07l I --RC RC'380t WO BY CONTRACTOR DESCRIPTION* LOW VOLTAGE SWGR RM VENT FAN .ti / ' .t! 1-1 r:::-1 ' ED T419 !f ;:xi \.._ _______ 1 v SPARE TO MV5305A <SCHEME BE1240> SEE DWG. E-608 SH.25 J.. 420 MV53050 19911 } 201\_ SH.4C ,im11 RC *. !Re SEE \ I v NOTE 4 TO MV5305B <SCHEME BE124t> SEE DWG. E-606 SH.25 XI.CL.TR <E> B <A> Tl. T2, T3 Xl,CL.TR, R.G,WO M BLOCK DIAGRAM NOTES: I. FOR GENERAL NOTES SEE DRAWING INDEX E-608. 2. FOR DETAILS OF LOCAL PUSHBUTTONS AND INDICATING LIGHTS SEE OWG. E-308 TYPES 3 8r 4. 3. TS/A CLOSES AT HIGH TEMPERATURE TS/B AND CLOSES ON LOW TEMPERATURE. SEE DRAWING M-7201 FOR SETPOINTS. 4. CONTRACTOR ro* REPLACE N.C. CONTACT 19-20 WITH N.O. CONTACT. 5. RELAY 42X IS A POTTER & BRUMFIELD MOR RELAY AND HAS 8 PDT CONTACTS. FOR SPARE CONTACTS . SEE DRAWINGS E-8-78 & E-80-165
  • SCALE NONE . . DESIGNED DRAW. JOR DATE 9/ 18/03 .NUCLEAR POWER STATION UNIT NO. 1 ELEMENTARY WIRING DIAGRAMS STA. HTG, VENTL. & CLNG. SYS. LOW VOLTAGE SWGR RM VENT FAN .l--1 DRAWING NO. E-608 SH.40 REY. 1