ML16344A417

From kanterella
Revision as of 12:23, 1 May 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 14, Table 14.4.6-12, Peak Differential Pressure Main Steam Line Break in East Steam Enclosure
ML16344A417
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16344A417 (1)


Text

IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 16.6Table: 14.4.6-12Page: 1 of 1 PEAK DIFFERENTIAL PRESSURE MAIN STEAM LINE BREAK IN EAST STEAM ENCLOSURE Element No. 1 Peak Pressure (psi) 1 0 2 7.7 3 7.8 4 (Break Location) 11.8 5 8.3 6 12.0 7 11.0 1 Element numbers refer to Figure 14.4.6-3. UNIT 2